Comparison of Pull-out Strength for Different Bone Block Length in a Porcine Anterior Cruciate Ligament Model.

PubWeight™: 0.75‹?›

🔗 View Article (PMC 4555541)

Published in Orthop J Sports Med on May 12, 2014

Authors

Matthew Posner1, Brett Owens1, Paul Johnson2, Noreen Masciello2, Kenneth Cameron1, Christopher Roach1, Steven Svoboda1, Bruce Floersheim2

Author Affiliations

1: Keller Army Community Hospital, West Point, New York, USA.
2: Department of Civil and Mechanical Engineering, United States Military Academy, West Point, New York, USA.

Articles cited by this

RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT. A TECHNIQUE USING THE CENTRAL ONE-THIRD OF THE PATELLAR LIGAMENT. J Bone Joint Surg Am (1963) 1.94

Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft: a biomechanical analysis. Arthroscopy (2006) 1.65

Anterior cruciate ligament reconstruction using one-third of the patellar ligament, augmented by extra-articular tendon transfers. J Bone Joint Surg Am (1982) 1.36

Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med (2001) 1.00

Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: influence of insertion torque, tunnel-bone block gap, and interference. Knee Surg Sports Traumatol Arthrosc (1996) 0.98

Porcine tibia is a poor substitute for human cadaver tibia for evaluating interference screw fixation. Am J Sports Med (2004) 0.94

Femoral tunnel length: accessory anteromedial portal drilling versus transtibial drilling. Arthroscopy (2012) 0.90

Regional variation in the mechanical properties of cortical bone from the porcine femur. Med Eng Phys (2011) 0.84

Bone plug length and loading angle determine the primary stability of patellar tendon-bone grafts in press-fit ACL reconstruction. Knee Surg Sports Traumatol Arthrosc (2005) 0.83

Resulting tensile forces in the human bone-patellar tendon-bone graft: direct force measurement in vitro. Arthroscopy (1999) 0.82

Biomechanical comparison between BioScrew and titanium alloy interference screws for bone-patellar tendon-bone graft fixation in anterior cruciate ligament reconstruction. Arthroscopy (1997) 0.82

Soft tissue tendon graft fixation in serially dilated or extraction-drilled tibial tunnels: a porcine model study using high-resolution quantitative computerized tomography. Am J Sports Med (2007) 0.80

Failure load of patellar tendon grafts at the femoral side: 10- versus 20-mm-bone blocks. Knee Surg Sports Traumatol Arthrosc (2008) 0.80