Differences in limb alignment and femoral mechanical-anatomical angles using two dimension versus three dimension radiographic imaging.

PubWeight™: 0.75‹?›

🔗 View Article (PMID 28236072)

Published in Int Orthop on February 24, 2017

Authors

Frédéric Sailhan1,2,3, Louis Jacob4,5, Moussa Hamadouche4,5

Author Affiliations

1: Hospital Cochin, Paris, France. dr.sailhan@gmail.com.
2: University of Paris 5, Paris, France. dr.sailhan@gmail.com.
3: Clinic «Arago», Paris, France. dr.sailhan@gmail.com.
4: Hospital Cochin, Paris, France.
5: University of Paris 5, Paris, France.

Articles cited by this

Radiological assessment of osteo-arthrosis. Ann Rheum Dis (1957) 42.98

Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res (2002) 5.19

Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am (2010) 4.53

Coronal alignment after total knee replacement. J Bone Joint Surg Br (1991) 4.04

Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am (1987) 3.25

Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am (1977) 2.97

Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res (1990) 2.86

Axial alignment of the lower extremity in Chinese adults. J Bone Joint Surg Am (2000) 2.02

Anatomic variations should be considered in total knee arthroplasty. J Orthop Sci (2000) 1.22

A comparison of coronal plane axial femoral relationships in Asian patients with varus osteoarthritic knees and healthy knees. J Arthroplasty (2008) 1.21

Sagittal bowing of the distal femur in Chinese patients who require total knee arthroplasty. J Orthop Res (2005) 1.20

Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Engin (2011) 1.18

Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res (2000) 1.15

The EOS™ imaging system and its uses in daily orthopaedic practice. Int Orthop (2012) 1.13

Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg (2009) 1.09

Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system. Int Orthop (2011) 1.07

Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty. Clin Orthop Relat Res (1989) 1.05

Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study. Skeletal Radiol (2012) 0.99

Underestimation of varus angulation in knees with flexion deformity. Knee (2002) 0.94

Reliability of a new method for lower-extremity measurements based on stereoradiographic three-dimensional reconstruction. Orthop Traumatol Surg Res (2012) 0.94

Normal lower-extremity alignment parameters in healthy Southern Chinese adults as a guide in total knee arthroplasty. J Arthroplasty (2009) 0.92

Neutral mechanical alignment: a requirement for successful TKA: opposes. Orthopedics (2011) 0.92

New method for measuring acetabular component positioning with EOS imaging: feasibility study on dry bone. Int Orthop (2012) 0.92

Mechanical axis cannot be restored in total knee arthroplasty with a fixed valgus resection angle: a radiographic study. J Arthroplasty (2007) 0.89

Three dimensional radiological imaging of normal lower-limb alignment in children. Int Orthop (2015) 0.85

Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging. Int Orthop (2014) 0.85

Natural distribution of the femoral mechanical-anatomical angle in an osteoarthritic population and its relevance to total knee arthroplasty. Knee (2011) 0.83

5 degrees to 6 degrees of distal femoral cut for uncomplicated primary total knee arthroplasty: is it safe? Knee (2005) 0.82

Varus/valgus alignment of the femur in total knee arthroplasty. Can accuracy be improved by pre-operative CT scanning? Knee (2004) 0.78

Computed tomography scan scout film for measurement of femoral axis in knee replacement. J Arthroplasty (1999) 0.78

[Axial lower limb alignment and knee geometry in patients with osteoarthritis of the knee]. Rev Chir Orthop Reparatrice Appar Mot (2006) 0.77