Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla.

PubWeight™: 1.27‹?› | Rank: Top 10%

🔗 View Article (PMID 11891968)

Published in J Magn Reson Imaging on March 01, 2002

Authors

Ali R Rezai1, Daniel Finelli, John A Nyenhuis, Greg Hrdlicka, Jean Tkach, Ashwini Sharan, Paul Rugieri, Paul H Stypulkowski, Frank G Shellock

Author Affiliations

1: Section of Stereotactic and Functional Neurosurgery, Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland, Ohio, USA.

Articles citing this

Safety of retained microcatheters: an evaluation of radiofrequency heating in endovascular microcatheters with nitinol, tungsten, and polyetheretherketone braiding at 1.5 T and 3 T. J Neurointerv Surg (2013) 1.41

Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs. J Cardiovasc Magn Reson (2011) 1.12

Deep brain stimulation induces BOLD activation in motor and non-motor networks: an fMRI comparison study of STN and EN/GPi DBS in large animals. Neuroimage (2012) 1.06

Temperature measurement on neurological pulse generators during MR scans. Biomed Eng Online (2002) 1.02

Hazardous situation in the MR bore: induction in ECG leads causes fire. Eur Radiol (2003) 0.99

Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator. Magn Reson Imaging (2012) 0.97

Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: radiofrequency-induced heating. J Magn Reson Imaging (2008) 0.96

Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI. IEEE Trans Med Imaging (2010) 0.94

Effect of the extracranial deep brain stimulation lead on radiofrequency heating at 9.4 Tesla (400.2 MHz). J Magn Reson Imaging (2010) 0.94

A novel brain stimulation technology provides compatibility with MRI. Sci Rep (2015) 0.89

Heating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 T transceive volume head coil. Phys Med Biol (2012) 0.88

Temperature control at DBS electrodes using a heat sink: experimentally validated FEM model of DBS lead architecture. J Neural Eng (2012) 0.87

The subthalamic microlesion story in Parkinson's disease: electrode insertion-related motor improvement with relative cortico-subcortical hypoactivation in fMRI. PLoS One (2012) 0.85

MRI-related heating near deep brain stimulation electrodes: more data are needed. Stereotact Funct Neurosurg (2011) 0.84

Functional magnetic resonance imaging networks induced by intracranial stimulation may help defining the epileptogenic zone. Brain Connect (2014) 0.80

Cortical magnetoencephalography of deep brain stimulation for the treatment of postural tremor. Brain Stimul (2012) 0.80

Local SAR near deep brain stimulation (DBS) electrodes at 64 and 127 MHz: A simulation study of the effect of extracranial loops. Magn Reson Med (2016) 0.76

Computed three-dimensional atlas of subthalamic nucleus and its adjacent structures for deep brain stimulation in Parkinson's disease. ISRN Neurol (2012) 0.75

The preoperative neurological evaluation. Neurohospitalist (2013) 0.75

MR fingerprinting using the quick echo splitting NMR imaging technique. Magn Reson Med (2016) 0.75

Pathological alterations and stress responses near DBS electrodes after MRI scans at 7.0T, 3.0T and 1.5T: an in vivo comparative study. PLoS One (2014) 0.75

The Safety of Using Body-Transmit MRI in Patients with Implanted Deep Brain Stimulation Devices. PLoS One (2015) 0.75

Articles by these authors

Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla. J Am Coll Cardiol (2004) 4.44

Deep brain stimulation of the ventral capsule/ventral striatum for treatment-resistant depression. Biol Psychiatry (2008) 2.86

Safety and efficacy of peripheral nerve stimulation of the occipital nerves for the management of chronic migraine: results from a randomized, multicenter, double-blinded, controlled study. Cephalalgia (2012) 2.38

Obesity and spine surgery: relation to perioperative complications. J Neurosurg Spine (2007) 2.08

Assessment of MRI issues at 7 T for 28 implants and other objects. AJR Am J Roentgenol (2014) 2.06

Patellofemoral kinematics during weight-bearing and non-weight-bearing knee extension in persons with lateral subluxation of the patella: a preliminary study. J Orthop Sports Phys Ther (2003) 1.85

Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. Invest Radiol (2004) 1.82

Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating. J Magn Reson Imaging (2004) 1.71

Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain. Magn Reson Imaging (2005) 1.59

Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report. Neurosurgery (2005) 1.57

The mind's eye: functional MR imaging evaluation of golf motor imagery. AJNR Am J Neuroradiol (2003) 1.57

"MR-conditional" pacemakers: the radiologist's role in multidisciplinary management. AJR Am J Roentgenol (2011) 1.46

Identification of wrist and metacarpophalangeal joint erosions using a portable magnetic resonance imaging system compared to conventional radiographs. J Rheumatol (2004) 1.42

Spinal cord injury induced by a cervical spinal cord stimulator. Neuromodulation (2010) 1.40

Standardized MR terminology and reporting of implants and devices as recommended by the American College of Radiology Subcommittee on MR Safety. Radiology (2014) 1.40

Corpus callosotomy. Epilepsy Behav (2008) 1.36

A functional neuroimaging investigation of deep brain stimulation in patients with obsessive-compulsive disorder. J Neurosurg (2006) 1.32

Abnormalities in diffusion tensor imaging of the uncinate fasciculus relate to reduced memory in temporal lobe epilepsy. Epilepsia (2008) 1.31

Simultaneous use of neurostimulators in patients with a preexisting cardiovascular implantable electronic device. Neuromodulation (2010) 1.24

MR imaging-related heating of deep brain stimulation electrodes: in vitro study. AJNR Am J Neuroradiol (2002) 1.20

MR labeling information for implants and devices: explanation of terminology. Radiology (2009) 1.18

Neurological manifestations of cervical spondylosis: an overview of signs, symptoms, and pathophysiology. Neurosurgery (2007) 1.17

Comments on MR heating tests of critical implants. J Magn Reson Imaging (2007) 1.17

Greater corticolimbic activation to high-calorie food cues after eating in obese vs. normal-weight adults. Appetite (2011) 1.12

Central cord injury: pathophysiology, management, and outcomes. Spine J (2006) 1.12

Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs. J Cardiovasc Magn Reson (2011) 1.12

Is magnetic resonance imaging safe for patients with neurostimulation systems used for deep brain stimulation? Neurosurgery (2005) 1.10

Failure of standard imaging to detect a cervical fracture in a patient with ankylosing spondylitis. Spine (Phila Pa 1976) (2005) 1.07

Spontaneously reactivated patterns in frontal and temporal lobe predict semantic clustering during memory search. J Neurosci (2012) 1.03

Extratemporal functional connectivity impairments at rest are related to memory performance in mesial temporal epilepsy. Hum Brain Mapp (2012) 1.03

Risk factors for surgical site infections following spinal fusion procedures: a case-control study. Clin Infect Dis (2011) 1.03

Simulation of human respiration in fMRI with a mechanical model. IEEE Trans Biomed Eng (2002) 1.00

Computational and experimental studies of an orthopedic implant: MRI-related heating at 1.5-T/64-MHz and 3-T/128-MHz. J Magn Reson Imaging (2012) 0.99

Reduction of magnetic resonance imaging-related heating in deep brain stimulation leads using a lead management device. Neurosurgery (2005) 0.99

Evaluation of MRI artifacts at 3 Tesla for 38 commonly used cosmetics. Magn Reson Imaging (2013) 0.99

Simple design changes to wires to substantially reduce MRI-induced heating at 1.5 T: implications for implanted leads. Magn Reson Imaging (2005) 0.99

Effects of coil dimensions and field polarization on RF heating inside a head phantom. Magn Reson Imaging (2005) 0.98

Defining "complications" in spine surgery: neurosurgery and orthopedic spine surgeons' survey. J Spinal Disord Tech (2010) 0.97

Dermoid cyst of the pancreas: a case report with literature review. J Radiol Case Rep (2012) 0.95

8.0-Tesla human MR system: temperature changes associated with radiofrequency-induced heating of a head phantom. J Magn Reson Imaging (2003) 0.94

Surgical outcome in PET-positive, MRI-negative patients with temporal lobe epilepsy. Epilepsia (2011) 0.93

Evaluation of neurologic deficit without apparent cause: the importance of a multidisciplinary approach. J Spinal Cord Med (2007) 0.93

Cortical stimulation for language mapping in focal epilepsy: correlations with tractography of the arcuate fasciculus. Epilepsia (2009) 0.93

Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips. J Cardiovasc Magn Reson (2012) 0.92

Perioperative complications of minimally invasive surgery (MIS): comparison of MIS and open interbody fusion techniques. Surg Technol Int (2008) 0.92

Recurrent laryngeal nerve palsy after anterior cervical spine surgery: the impact of endotracheal tube cuff deflation, reinflation, and pressure adjustment. Anesthesiology (2006) 0.92

Assessment of patellofemoral relationships using kinematic MRI: comparison between qualitative and quantitative methods. J Magn Reson Imaging (2002) 0.92

Armor-piercing bullet: 3-T MRI findings and identification by a ferromagnetic detection system. Mil Med (2013) 0.91

Functional connectivity evidence of cortico-cortico inhibition in temporal lobe epilepsy. Hum Brain Mapp (2012) 0.90

MRI issues for ballistic objects: information obtained at 1.5-, 3- and 7-Tesla. Spine J (2013) 0.90

Intracranial EEG in predicting surgical outcome in frontal lobe epilepsy. Epilepsia (2012) 0.89

Spinal cord stimulation: an update. Neurotherapeutics (2008) 0.89

Hippocampal functional connectivity patterns during spatial working memory differ in right versus left temporal lobe epilepsy. Brain Connect (2013) 0.88

Neurostimulation systems: assessment of magnetic field interactions associated with 1.5- and 3-Tesla MR systems. J Magn Reson Imaging (2005) 0.88

An evaluation of neuroplasticity and behavior after deep brain stimulation of the nucleus accumbens in an animal model of depression. Neurosurgery (2011) 0.87

The effectiveness of low-frequency stimulation for mapping cortical function. Epilepsia (2007) 0.86

Acute cervical fracture or congenital spinal deformity? J Spinal Cord Med (2008) 0.86

Timing in the surgical evacuation of spinal epidural abscesses. Neurosurg Focus (2014) 0.85

Parallel excitation for B-field insensitive fat-saturation preparation. Magn Reson Med (2012) 0.85

Quantitative prediction of spinal cord drift after cervical laminectomy and arthrodesis. Spine (Phila Pa 1976) (2006) 0.85

Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function. J Magn Reson Imaging (2007) 0.85

Electrical stimulation as therapy for neurological disorder. IEEE Eng Med Biol Mag (2006) 0.84

Decoding the memorization of individual stimuli with direct human brain recordings. Neuroimage (2013) 0.84

MR in patients with pacemakers and ICDs: Defining the issues. J Cardiovasc Magn Reson (2007) 0.84

Assessment of MRI issues for the Argus II retinal prosthesis. Magn Reson Imaging (2012) 0.84

Brain atrophy and magnetization transfer ratio following methylprednisolone in multiple sclerosis: short-term changes and long-term implications. Mult Scler (2005) 0.83

Evaluation of magnetic resonance imaging issues for implantable microfabricated magnetic actuators. Biomed Microdevices (2014) 0.83

Early and late age of seizure onset have a differential impact on brain resting-state organization in temporal lobe epilepsy. Brain Topogr (2014) 0.82

Resting-state functional connectivity predicts the strength of hemispheric lateralization for language processing in temporal lobe epilepsy and normals. Hum Brain Mapp (2014) 0.82

Tempo mediates the involvement of motor areas in beat perception. Ann N Y Acad Sci (2012) 0.82

Repeated stimuli elicit diminished high-gamma electrocorticographic responses. Neuroimage (2013) 0.81

Implantable microstimulator: magnetic resonance safety at 1.5 Tesla. Invest Radiol (2004) 0.81

A test of the role of the medial temporal lobe in single-word decoding. Neuroimage (2010) 0.81

Magnetic resonance imaging and permanent cosmetics (tattoos): survey of complications and adverse events. J Magn Reson Imaging (2002) 0.81

Complications in spinal surgery: comparative survey of spine surgeons and patients who underwent spinal surgery. J Neurosurg Spine (2009) 0.81

Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead. J Magn Reson Imaging (2002) 0.81

Employment after anterior temporal lobectomy. Epilepsia (2011) 0.81

MRI information for commonly used otologic implants: review and update. Otolaryngol Head Neck Surg (2014) 0.81

Developing a neurosurgical simulation-based educational curriculum: an overview. Neurosurgery (2013) 0.80

Neurosurgical training with a novel cervical spine simulator: posterior foraminotomy and laminectomy. Neurosurgery (2013) 0.80

Reduction in neural activation to high-calorie food cues in obese endometrial cancer survivors after a behavioral lifestyle intervention: a pilot study. BMC Neurosci (2012) 0.80

Hemispheric lateralization and language skill coherence in temporal lobe epilepsy. Cortex (2009) 0.79

Increased microstructural white matter correlations in left, but not right, temporal lobe epilepsy. Hum Brain Mapp (2014) 0.79

In vitro assessment of a fiducial marker for lung lesions: MRI issues at 3 T. AJR Am J Roentgenol (2013) 0.79

Dual occipital and supraorbital nerve stimulation for chronic migraine: a single-center experience, review of literature, and surgical considerations. Neurosurg Focus (2013) 0.79

Undisclosed and undetected foreign bodies during MRI screening resulting in a potentially serious outcome. Magn Reson Imaging (2013) 0.79

Comparison of the threshold for peripheral nerve stimulation during gradient switching in whole body MR systems. J Magn Reson Imaging (2002) 0.79

An investigation of implicit memory through left temporal lobectomy for epilepsy. Neurobiol Learn Mem (2012) 0.78