A population study on changes in wave aberrations with accommodation.

PubWeight™: 1.59‹?› | Rank: Top 4%

🔗 View Article (PMID 15134474)

Published in J Vis on April 16, 2004

Authors

Han Cheng1, Justin K Barnett, Abhiram S Vilupuru, Jason D Marsack, Sanjeev Kasthurirangan, Raymond A Applegate, Austin Roorda

Author Affiliations

1: College of Optometry, University of Houston, Houston, TX 77204-2020, USA. hcheng@optometry.uh.edu

Articles citing this

Vergence-accommodation conflicts hinder visual performance and cause visual fatigue. J Vis (2008) 3.71

Predicting crystalline lens fall caused by accommodation from changes in wavefront error. J Cataract Refract Surg (2011) 1.40

Adaptive optics technology for high-resolution retinal imaging. Sensors (Basel) (2012) 1.30

Accommodative changes in lens diameter in rhesus monkeys. Invest Ophthalmol Vis Sci (2006) 1.28

Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging. J Opt Soc Am A Opt Image Sci Vis (2007) 1.24

Changes in crystalline lens radii of curvature and lens tilt and decentration during dynamic accommodation in rhesus monkeys. J Vis (2008) 1.11

Characteristics of accommodative behavior during sustained reading in emmetropes and myopes. Vision Res (2006) 1.07

Wave aberrations of the isolated crystalline lens. J Vis (2003) 1.04

Objective accommodation measurements in prepresbyopic eyes using an autorefractor and an aberrometer. J Cataract Refract Surg (2008) 1.03

Influence of shape and gradient refractive index in the accommodative changes of spherical aberration in nonhuman primate crystalline lenses. Invest Ophthalmol Vis Sci (2013) 1.02

Accommodation in emmetropic and myopic young adults wearing bifocal soft contact lenses. Ophthalmic Physiol Opt (2008) 1.01

Accommodation and induced myopia in marmosets. Vision Res (2007) 0.97

Determining the accommodative response from wavefront aberrations. J Vis (2010) 0.87

Empirical variability in the calibration of slope-based eccentric photorefraction. J Opt Soc Am A Opt Image Sci Vis (2013) 0.87

Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors. J Vis (2013) 0.86

Higher order monochromatic aberrations of the human infant eye. J Vis (2005) 0.85

Optical and biometric characteristics of anisomyopia in human adults. Ophthalmic Physiol Opt (2011) 0.84

[Accommodation and presbyopia : part 1: physiology of accommodation and development of presbyopia]. Ophthalmologe (2008) 0.82

Optical quality of the diabetic eye: a review. Eye (Lond) (2014) 0.82

Influence of cycloplegia with topical cyclopentolate on higher-order aberrations in myopic children. Eye (Lond) (2014) 0.81

Focus information is used to interpret binocular images. J Vis (2010) 0.81

Subjective versus objective accommodative amplitude: preschool to presbyopia. Optom Vis Sci (2014) 0.81

Effect of temporal location of correction of monochromatic aberrations on the dynamic accommodation response. Biomed Opt Express (2010) 0.80

An analytical method for predicting the geometrical and optical properties of the human lens under accommodation. Biomed Opt Express (2014) 0.80

Ocular higher-order aberrations in a school children population. J Optom (2014) 0.80

Potential signal to accommodation from the Stiles-Crawford effect and ocular monochromatic aberrations. J Mod Opt (2009) 0.80

Utility of an open field Shack-Hartmann aberrometer for measurement of refractive error in infants and young children. J AAPOS (2013) 0.80

Peripheral aberrations and image quality for contact lens correction. Optom Vis Sci (2011) 0.79

Wave aberrations in rhesus monkeys with vision-induced ametropias. Vision Res (2007) 0.79

The impact of higher-order aberrations on the strength of directional signals produced by accommodative microfluctuations. J Vis (2014) 0.79

Depth-of-field of the accommodating eye. Optom Vis Sci (2014) 0.78

Monochromatic ocular wave aberrations in young monkeys. Vision Res (2006) 0.78

Controlled induction of spherical aberration with custom soft contact lenses. Clin Exp Optom (2009) 0.78

[Monochromatic aberration in accommodation. Dynamic wavefront analysis]. Ophthalmologe (2011) 0.78

Variation of axial and oblique astigmatism with accommodation across the visual field. J Vis (2017) 0.77

Accommodative changes produced in response to overnight orthokeratology. Graefes Arch Clin Exp Ophthalmol (2014) 0.77

Measurement of wavefront aberrations and lens deformation in the accommodated eye with optical coherence tomography-equipped wavefront system. Opt Express (2014) 0.77

Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics. Jpn J Ophthalmol (2007) 0.76

Compensation of corneal oblique astigmatism by internal optics: a theoretical analysis. Ophthalmic Physiol Opt (2017) 0.76

Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system. Int J Ophthalmol (2015) 0.75

Wavefront aberration changes caused by a gradient of increasing accommodation stimuli. Eye (Lond) (2014) 0.75

Changes in monkey crystalline lens spherical aberration during simulated accommodation in a lens stretcher. Invest Ophthalmol Vis Sci (2015) 0.75

Progression of lower and higher-order aberrations: a longitudinal study. BMC Ophthalmol (2015) 0.75

Asymmetric wavefront aberrations and pupillary shapes induced by electrical stimulation of ciliary nerve in cats measured with compact wavefront aberrometer. PLoS One (2014) 0.75

Clinical performance of a new aspheric dual-optic accommodating intraocular lens. Clin Ophthalmol (2014) 0.75

[The influence of eye movements on monochromatic wavefront aberrations]. Ophthalmologe (2010) 0.75

Articles by these authors

Adaptive optics scanning laser ophthalmoscopy. Opt Express (2002) 6.29

High-resolution imaging with adaptive optics in patients with inherited retinal degeneration. Invest Ophthalmol Vis Sci (2007) 3.21

Automated identification of cone photoreceptors in adaptive optics retinal images. J Opt Soc Am A Opt Image Sci Vis (2007) 2.44

MEMS-based adaptive optics scanning laser ophthalmoscopy. Opt Lett (2006) 2.25

Retinal motion estimation in adaptive optics scanning laser ophthalmoscopy. Opt Express (2006) 2.21

Accuracy and precision of objective refraction from wavefront aberrations. J Vis (2004) 2.15

Standards for reporting the optical aberrations of eyes. J Refract Surg (2002) 2.15

Revealing Henle's fiber layer using spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci (2011) 2.14

Longitudinal study of cone photoreceptors during retinal degeneration and in response to ciliary neurotrophic factor treatment. Invest Ophthalmol Vis Sci (2011) 2.14

High-resolution retinal imaging of cone-rod dystrophy. Ophthalmology (2006) 2.13

The relationship between visual resolution and cone spacing in the human fovea. Nat Neurosci (2009) 2.10

Retinally stabilized cone-targeted stimulus delivery. Opt Express (2007) 2.06

Noninvasive visualization and analysis of parafoveal capillaries in humans. Invest Ophthalmol Vis Sci (2009) 1.91

Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope. Biomed Opt Express (2011) 1.89

The relationship between nerve fiber layer and perimetry measurements. Invest Ophthalmol Vis Sci (2007) 1.83

Intersubject variability of foveal cone photoreceptor density in relation to eye length. Invest Ophthalmol Vis Sci (2010) 1.81

Intrinsic signals from human cone photoreceptors. Invest Ophthalmol Vis Sci (2008) 1.81

Interaction between aberrations to improve or reduce visual performance. J Cataract Refract Surg (2003) 1.72

Direct and noninvasive assessment of parafoveal capillary leukocyte velocity. Ophthalmology (2005) 1.69

Real-time eye motion correction in phase-resolved OCT angiography with tracking SLO. Biomed Opt Express (2012) 1.58

Resolving single cone inputs to visual receptive fields. Nat Neurosci (2009) 1.58

Visual performance in emmetropia and low myopia after correction of high-order aberrations. J Vis (2007) 1.57

Adaptive optics retinal imaging: emerging clinical applications. Optom Vis Sci (2010) 1.53

MEMS segmented-based adaptive optics scanning laser ophthalmoscope. Biomed Opt Express (2011) 1.48

Adaptive optics scanning laser ophthalmoscopy images in a family with the mitochondrial DNA T8993C mutation. Invest Ophthalmol Vis Sci (2008) 1.42

Characterization of single-file flow through human retinal parafoveal capillaries using an adaptive optics scanning laser ophthalmoscope. Biomed Opt Express (2011) 1.40

Predicting crystalline lens fall caused by accommodation from changes in wavefront error. J Cataract Refract Surg (2011) 1.40

Age-related changes in optical and biometric characteristics of emmetropic eyes. J Vis (2008) 1.38

Imaging and measurement in the eye: now and ahead. Optom Vis Sci (2012) 1.38

Real-time eye motion compensation for OCT imaging with tracking SLO. Biomed Opt Express (2012) 1.38

Cone photoreceptor abnormalities correlate with vision loss in patients with Stargardt disease. Invest Ophthalmol Vis Sci (2011) 1.37

Optical slicing of human retinal tissue in vivo with the adaptive optics scanning laser ophthalmoscope. Appl Opt (2005) 1.34

High-speed, image-based eye tracking with a scanning laser ophthalmoscope. Biomed Opt Express (2012) 1.33

Design of an integrated hardware interface for AOSLO image capture and cone-targeted stimulus delivery. Opt Express (2010) 1.33

Metrics of optical quality derived from wave aberrations predict visual performance. J Vis (2004) 1.32

High-resolution images of retinal structure in patients with choroideremia. Invest Ophthalmol Vis Sci (2013) 1.27

Cone structure in retinal degeneration associated with mutations in the peripherin/RDS gene. Invest Ophthalmol Vis Sci (2011) 1.24

Deletion of the X-linked opsin gene array locus control region (LCR) results in disruption of the cone mosaic. Vision Res (2010) 1.24

Disruption of the retinal parafoveal capillary network in type 2 diabetes before the onset of diabetic retinopathy. Invest Ophthalmol Vis Sci (2011) 1.24

Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging. J Opt Soc Am A Opt Image Sci Vis (2007) 1.24

Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye. Biomed Opt Express (2012) 1.23

Evaluating the lateral resolution of the adaptive optics scanning laser ophthalmoscope. J Biomed Opt (2006) 1.20

Adaptive optics scanning laser ophthalmoscopy for in vivo imaging of lamina cribrosa. J Opt Soc Am A Opt Image Sci Vis (2007) 1.19

Optimal pupil size in the human eye for axial resolution. J Opt Soc Am A Opt Image Sci Vis (2003) 1.17

Monochromatic aberrations provide an odd-error cue to focus direction. J Opt Soc Am A Opt Image Sci Vis (2002) 1.15

Adaptive optics scanning laser ophthalmoscope-based microperimetry. Optom Vis Sci (2012) 1.15

Objective accommodation measurement with the Grand Seiko and Hartinger coincidence refractometer. Optom Vis Sci (2007) 1.13

Pulsatility of parafoveal capillary leukocytes. Exp Eye Res (2008) 1.12

Subclinical capillary changes in non-proliferative diabetic retinopathy. Optom Vis Sci (2012) 1.12

Dynamic visual stimulus presentation in an adaptive optics scanning laser ophthalmoscope. J Refract Surg (2005) 1.11

Theoretical modeling and evaluation of the axial resolution of the adaptive optics scanning laser ophthalmoscope. J Biomed Opt (2004) 1.10

Amplitude dependent accommodative dynamics in humans. Vision Res (2003) 1.08

Multi-wavelength imaging with the adaptive optics scanning laser Ophthalmoscope. Opt Express (2006) 1.07

Accommodative lens refilling in rhesus monkeys. Invest Ophthalmol Vis Sci (2006) 1.07

Effects of optically imposed astigmatism on emmetropization in infant monkeys. Invest Ophthalmol Vis Sci (2004) 1.06

Abnormal cone structure in foveal schisis cavities in X-linked retinoschisis from mutations in exon 6 of the RS1 gene. Invest Ophthalmol Vis Sci (2011) 1.05

Modeling the foveal cone mosaic imaged with adaptive optics scanning laser ophthalmoscopy. Opt Express (2010) 1.04

Making sense out of wavefront sensing. Am J Ophthalmol (2005) 1.02

Identification of a novel mutation in the CDHR1 gene in a family with recessive retinal degeneration. Arch Ophthalmol (2012) 1.02

Mapping the perceptual grain of the human retina. J Neurosci (2014) 1.02

Spatially variant changes in lens power during ocular accommodation in a rhesus monkey eye. J Vis (2004) 1.01

Detecting significant change in wavefront error: how long does it take? Clin Exp Optom (2009) 1.01

Outer retinal structure in patients with acute zonal occult outer retinopathy. Am J Ophthalmol (2011) 1.01

Measuring visual acuity--mesopic or photopic conditions, and high or low contrast letters? J Refract Surg (2004) 0.99

Metrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity. Optom Vis Sci (2006) 0.99

Uncorrected wavefront error and visual performance during RGP wear in keratoconus. Optom Vis Sci (2007) 0.98

The precision of wavefront refraction compared to subjective refraction and autorefraction. Optom Vis Sci (2007) 0.97

Simultaneous measurements of refraction and A-scan biometry during accommodation in humans. Optom Vis Sci (2006) 0.97

Speed quantification and tracking of moving objects in adaptive optics scanning laser ophthalmoscopy. J Biomed Opt (2011) 0.96

Is visual resolution after adaptive optics correction susceptible to perceptual learning? J Vis (2010) 0.96

Quantifying scatter in Shack-Hartmann images to evaluate nuclear cataract. J Refract Surg (2004) 0.94

Performance of wavefront-guided soft lenses in three keratoconus subjects. Optom Vis Sci (2008) 0.93

Deconvolution of adaptive optics retinal images. J Opt Soc Am A Opt Image Sci Vis (2004) 0.92

DIRECTIONAL OPTICAL COHERENCE TOMOGRAPHY PROVIDES ACCURATE OUTER NUCLEAR LAYER AND HENLE FIBER LAYER MEASUREMENTS. Retina (2015) 0.92

Mutations in the small nuclear riboprotein 200 kDa gene (SNRNP200) cause 1.6% of autosomal dominant retinitis pigmentosa. Mol Vis (2013) 0.89

Comparison of spherical aberration and small-pupil profiles in improving depth of focus for presbyopic corrections. J Cataract Refract Surg (2012) 0.88

Comparison of Control Algorithms for a MEMS-based Adaptive Optics Scanning Laser Ophthalmoscope. Proc Am Control Conf (2009) 0.88

Relationship between foveal cone structure and clinical measures of visual function in patients with inherited retinal degenerations. Invest Ophthalmol Vis Sci (2013) 0.88

How the unstable eye sees a stable and moving world. J Vis (2013) 0.88

Predicting and assessing visual performance with multizone bifocal contact lenses. Optom Vis Sci (2003) 0.88

On-eye performance of custom wavefront-guided soft contact lenses in a habitual soft lens-wearing keratoconic patient. J Refract Surg (2007) 0.87

Visual function and cortical organization in carriers of blue cone monochromacy. PLoS One (2013) 0.87

Determining the accommodative response from wavefront aberrations. J Vis (2010) 0.87

Dynamics of accommodative fatigue in rhesus monkeys and humans. Vision Res (2005) 0.87

Cone structure in patients with usher syndrome type III and mutations in the Clarin 1 gene. JAMA Ophthalmol (2013) 0.87

Psychophysical measurements of referenced and unreferenced motion processing using high-resolution retinal imaging. J Vis (2008) 0.86

Evaluation of a satisfied bilateral scleral expansion band patient. J Cataract Refract Surg (2004) 0.86

Change in visual acuity is highly correlated with change in six image quality metrics independent of wavefront error and/or pupil diameter. J Vis (2012) 0.86

Change in visual acuity is well correlated with change in image-quality metrics for both normal and keratoconic wavefront errors. J Vis (2013) 0.86

Meta-analysis of sex differences in presbyopia. Invest Ophthalmol Vis Sci (2012) 0.86

Impact of Zernike-fit error on simulated high- and low-contrast acuity in keratoconus: implications for using Zernike-based corrections. J Opt Soc Am A Opt Image Sci Vis (2006) 0.85

Six just-noticeable differences in retinal image quality in 1 line of visual acuity: toward quantification of happy versus unhappy patients with 20/20 acuity. J Cataract Refract Surg (2011) 0.85

Applying wavefront sensors and corneal topography to keratoconus. Biomed Sci Instrum (2002) 0.85

Contributions of optical and non-optical blur to variation in visual acuity. Optom Vis Sci (2011) 0.84

Heterogeneous patterns of tissue injury in NARP syndrome. J Neurol (2010) 0.84

Wavefront-guided scleral lens correction in keratoconus. Optom Vis Sci (2014) 0.82