Mass transfers in a fluidized bed bioreactor using alginate beads for a future bioartificial liver.

PubWeight™: 0.85‹?›

🔗 View Article (PMID 15163062)

Published in Int J Artif Organs on April 01, 2004

Authors

B David1, E Doré, M Y Jaffrin, C Legallais

Author Affiliations

1: Université de Technologie de Compiègne, Laboratoire de Biomécanique et Génie Biomedical, Compiègne, France.

Articles by these authors

Artificial and bioartificial liver devices: present and future. Gut (2009) 1.14

Development of obesity in Zucker rats. Early insulin resistance in muscles but normal sensitivity in white adipose tissue. Diabetes (1987) 1.06

Impact of alginate type and bead diameter on mass transfers and the metabolic activities of encapsulated C3A cells in bioartificial liver applications. Eur Cell Mater (2011) 0.93

Investigations into the relationship between hemodynamics and vascular alterations in an established arteriovenous fistula. Med Eng Phys (2006) 0.91

The impact of eating habits on anthropometric characteristics in French primary school children. Child Care Health Dev (2010) 0.89

Effects of age and recovery duration on peak power output during repeated cycling sprints. Int J Sports Med (2002) 0.89

Aortic input impedance in heart failure: comparison with normal subjects and its changes during vasodilator therapy. Eur Heart J (1984) 0.87

Aortic input impedance in normal man and arterial hypertension: its modification during changes in aortic pressure. Cardiovasc Res (1982) 0.87

A computer simulation of arterial dynamics in the human leg. J Biomech (1974) 0.86

A new concept of bioartificial liver based on a fluidized bed bioreactor. Ther Apher (1999) 0.86

Blood flow patterns in an anatomically realistic coronary vessel: influence of three different reconstruction methods. J Biomech (2002) 0.86

Dynamic filtration of blood: a new concept for enhancing plasma filtration. Int J Artif Organs (1991) 0.84

Urea, creatinine and phosphate kinetic modeling during dialysis: application to pediatric hemodialysis. Int J Artif Organs (1995) 0.82

Culture of C3A cells in alginate beads for fluidized bed bioartificial liver. Transplant Proc (2007) 0.82

Forward and backward waves in the arterial system, their relationship to pressure waves form. Eur Heart J (1983) 0.82

Three-dimensional growth of human hepatoma C3A cells within alginate beads for fluidized bioartificial liver. Int J Artif Organs (2008) 0.80

[Paediatric case report of an acquired autoimmune thrombotic thrombocytopenic purpura]. Arch Pediatr (2006) 0.79

Design of a fluidized bed bioartificial liver. Artif Organs (2000) 0.79

Kinetic modelling as a tool for the design of a vascular bioartificial pancreas: feedback between modelling and experimental validation. Comput Methods Programs Biomed (1991) 0.79

Plasma filtration in Couette flow membrane devices. Artif Organs (1989) 0.79

Extracorporeal photochemotherapy as second- or first-line therapy of acute GVHD? Bone Marrow Transplant (2009) 0.78

A U-shaped bioartificial pancreas with rapid glucose-insulin kinetics. In vitro evaluation and kinetic modelling. Diabetes (1984) 0.78

Continuous measurements by impedance of haematocrit and plasma volume variations during dialysis. Med Biol Eng Comput (1997) 0.78

Mechanical properties of alginate beads hosting hepatocytes in a fluidized bed bioreactor. Int J Artif Organs (2006) 0.78

Albumin recovery enhancement in membrane plasma fractionation using pulsatile flow. Int J Artif Organs (1991) 0.78

Arterio-venous fistula: two cases realistic numerical blood flow simulations. Conf Proc IEEE Eng Med Biol Soc (2007) 0.77

A feasibility study of a filtration type autotransfusion device. J Biomed Eng (1993) 0.77

Development and validation of a bioartificial liver device with fluidized bed bioreactors hosting alginate-encapsulated hepatocyte spheroids. Conf Proc IEEE Eng Med Biol Soc (2015) 0.77

In vitro removal of human IgG autoantibodies by affinity filtration using immobilized L-histidine onto PEVA hollow fiber membranes. Biomol Eng (2001) 0.77

In vitro study of combined convection- diffusion mass transfer in hemodialysers. Int J Artif Organs (1984) 0.77

A bridge from bioimpedance spectroscopy to 50 kHz bioimpedance analysis: application to total body water measurements. Physiol Meas (2008) 0.77

Fluid volumes determination by impedance spectroscopy and hematocrit monitoring: application to pediatric hemodialysis. Artif Organs (2001) 0.76

A process for enhancing selectivity and limiting plugging in plasmafractionation for APOB removal. Int J Artif Organs (1993) 0.75

The effect of red blood cell flexibility on blood flow through tubes with diameters in the range 30 to 500 microns. Biorheology (1979) 0.75

Membrane plasma separation through small-area, hollow-fiber filters. Artif Organs (1986) 0.75

Functionalized hollow fiber membrane cartridge for adsorption of Anticofactor/Antiphospholipid antibodies: a potential tool for treatment. Artif Organs (1999) 0.75

Flows of red blood cell suspensions through narrow two-dimensional channels. Biorheology (1982) 0.75

Comparison of polyamide and polypropylene membranes for plasma separation. Int J Artif Organs (1991) 0.75

Treatment of a stenosed arteriovenous fistula by balloon angioplasty with or without stenting: comparison of effects on haemodynamics. Comput Methods Biomech Biomed Engin (2013) 0.75

Time and pressure dependence of sieving coefficients during membrane plasma fractionation. ASAIO Trans (1991) 0.75

Modelling of plasma-separation through microporous membranes. Int J Artif Organs (1989) 0.75

Microfiltration and ultrafiltration of polysaccharides produced by fermentation using a rotating disk dynamic filtration system. Biotechnol Bioeng (2003) 0.75

Plasma fractionation by dead-end membrane filtration: effects of membrane properties and plasma flux. Biorheology (1991) 0.75

Hemolysis reduction in plasmapheresis by module design: operating with pulsed flow filtration enhancement. Int J Artif Organs (1993) 0.75

The dependency of calcium set point on basal plasma calcium in dialysis patients: a better explanation for the discrepancies regarding its link with PTH secretion than methodological differences. Clin Nephrol (1998) 0.75

Endotoxin removal with poly(ethyleneimine)-immobilized adsorbers: Sepharose 4B versus flat sheet and hollow fibre membranes. J Chromatogr B Biomed Sci Appl (1998) 0.75

[Megakaryoblastic acute leukemia: bone and joint manifestations in a 7-month-old child]. Arch Pediatr (2012) 0.75

High efficiency plasmapheresis using rotating membrane device. Life Support Syst (1988) 0.75

Interactions between platelets and red blood cells in plasma filtration. Trans Am Soc Artif Intern Organs (1983) 0.75

A model of hemolysis in membrane plasmapheresis. ASAIO Trans (1987) 0.75

Protein adsorption on histidyl-aminohexyl-Sepharose 4B. II. Application to the negative one-step affinity purification of human beta2-microglobulin and immunoglobulin G. J Chromatogr B Biomed Sci Appl (2001) 0.75

The intra-aortic balloon for left heart assistance: an analytic model. J Biomech (1971) 0.75

Proceedings: A screening method for deep venous thrombosis. Thromb Diath Haemorrh (1975) 0.75

Calibration-free mercury strain-gauge plethysmograph. Med Biol Eng Comput (1979) 0.75

Design analysis of parallel plate and hollow fibres haemofilters. Med Biol Eng Comput (1981) 0.75

[Pressure distribution in a model of the central airways for sinusoidal flow]. Bull Physiopathol Respir (Nancy) (1973) 0.75

In vitro evaluation of a bioartificial pancreas under various hemodynamic conditions. Artif Organs (1989) 0.75

Computational flow dynamics based on an intracranial aneurysm animal model. Comput Methods Biomech Biomed Engin (2012) 0.75

Factors governing hemofiltration (HF) in a parallel plate exchanger with highly permeable membranes. Trans Am Soc Artif Intern Organs (1978) 0.75

A model of ultrafiltration and glucose mass transfer kinetics in peritoneal dialysis. Artif Organs (1987) 0.75

[Measuring bioimpedance in dialysis patients for determining the amount of water in individual fluid compartments of the body]. Biomed Tech (Berl) (1998) 0.75

A U-shaped flat membrane bio-artificial pancreas. Application of the ultrafiltration-based model to its design. Life Support Syst (1983) 0.75

A one-dimensional model of simultaneous hemodialysis and ultrafiltration with highly permeable membranes. J Biomech Eng (1981) 0.75

Quantitative interpretation of arterial impedance plethysmographic signals. Med Biol Eng Comput (1979) 0.75

Effect of membrane dimensions and shear rate on plasma filtration for hollow fibers. Trans Am Soc Artif Intern Organs (1984) 0.75

Hemolysis during membrane plasma separation with pulsed flow filtration enhancement. J Biomech Eng (1994) 0.75

Pulsed flow cascade filtration. Long-term experience in low density lipoprotein and lipoprotein a removal. ASAIO J (1997) 0.75

High shear rate hemofiltration: influence of fiber dimensions and shear rates. Artif Organs (1989) 0.75

[Aortic pressure and velocity signals processing: application to human aorta characterization (author's transl)]. J Physiol (Paris) (1980) 0.75

A three-layer semi-empirical model for flow of blood and other particulate suspensions through narrow tubes. J Biomech Eng (1982) 0.75

Reversibility of artifacts of fluid volume measurements by bioimpedance caused by position changes during dialysis. Int J Artif Organs (2002) 0.75

Influence of fermentation conditions and microfiltration processes on membrane fouling during recovery of glucuronane polysaccharides from fermentation broths. Biotechnol Bioeng (1999) 0.75

A noninvasive pressure-pulse recorder: development and rationale. Med Instrum (1973) 0.75

A high selectivity cascade filtration technique for LDL-cholesterol and Lp(a) removal. Artif Organs (1995) 0.75

Airway resistance: a fluid mechanical approach. J Appl Physiol (1974) 0.75

Effect of shear rate and transmembrane pressure on hemolysis in membrane plasmapheresis. Life Support Syst (1985) 0.75