Influence of screw-cement enhancement on the stability of anterior thoracolumbar fracture stabilization with circumferential instability.

PubWeight™: 0.78‹?›

🔗 View Article (PMC 3476664)

Published in Eur Spine J on June 22, 2004

Authors

Markus Schultheiss1, Erich Hartwig, Lutz Claes, Lothar Kinzl, Hans-Joachim Wilke

Author Affiliations

1: Department of Trauma, Hand and Reconstructive Surgery, University of Ulm, Ulm, Germany.

Articles cited by this

The stabilizing system of the spine. Part I. Function, dysfunction, adaptation, and enhancement. J Spinal Disord (1992) 5.68

The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. J Spinal Disord (1992) 4.04

Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J (1998) 2.99

A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J (1994) 1.65

Endoscopic techniques in spinal surgery. Clin Orthop Relat Res (1997) 1.28

A technical report on video-assisted thoracoscopy in thoracic spinal surgery. Preliminary description. Spine (Phila Pa 1976) (1995) 1.27

The stability of reconstruction methods after thoracolumbar total spondylectomy. An in vitro investigation. Spine (Phila Pa 1976) (1999) 1.14

[Endoscopically controlled division of the diaphragm. A minimally invasive approach to ventral management of thoracolumbar fractures of the spine]. Unfallchirurg (1998) 1.04

Video-assisted thoracoscopic excision of herniated thoracic disc: description of technique and preliminary experience in the first 29 cases. J Spinal Disord (1998) 1.03

Experimental study of thoracolumbar burst fractures. A radiographic and biomechanical analysis of anterior and posterior instrumentation systems. Spine (Phila Pa 1976) (1994) 1.03

In vitro biomechanical analysis of three anterior thoracolumbar implants. J Neurosurg (2000) 1.00

Biomechanical evaluation of anterior thoracolumbar spinal instrumentation. Spine (Phila Pa 1976) (1995) 0.99

Thoracic vertebrectomy and reconstruction using a microsurgical thoracoscopic approach. Neurosurgery (1996) 0.99

[Minimally invasive ventral spondylodesis in injuries to the thoracic and lumbar spine]. Chirurg (1997) 0.99

[Thoracoscopy-guided management of the "anterior column". Methods and results]. Orthopade (1999) 0.97

Biomechanical analysis of anterior and posterior instrumentation systems after corpectomy. A calf-spine model. J Bone Joint Surg Am (1988) 0.95

Video-assisted thoracoscopic surgery versus open thoracotomy for anterior thoracic spinal fusion. A comparative radiographic, biomechanical, and histologic analysis in a sheep model. Spine (Phila Pa 1976) (1998) 0.95

Video-assisted thoracic surgery for the anterior approach to the thoracic spine. Ann Thorac Surg (1995) 0.95

Biomechanical studies on two anterior thoracolumbar implants in cadaveric spines. Spine (Phila Pa 1976) (1999) 0.92

Static and fatigue biomechanical properties of anterior thoracolumbar instrumentation systems. A synthetic testing model. Spine (Phila Pa 1976) (1999) 0.92

Biomechanical evaluation of spinal fixation devices. Part III. Stability provided by six spinal fixation devices and interbody bone graft. Spine (Phila Pa 1976) (1989) 0.91

Video-assisted thoracoscopic treatment of spinal lesions in the thoracolumbar junction. Surg Endosc (1997) 0.90

Anterior instrumentation of the thoracolumbar spine. A biomechanical comparison. Spine (Phila Pa 1976) (1997) 0.90

Anterior spinal fixators. A biomechanical in vitro study. Spine (Phila Pa 1976) (1993) 0.89

Analysis of techniques for video-assisted thoracoscopic internal fixation of the spine. Arch Orthop Trauma Surg (1998) 0.88

Biomechanical analysis of anterior versus circumferential spinal reconstruction for various anatomic stages of tumor lesions. Spine (Phila Pa 1976) (1999) 0.84

Axial compression force measurement acting across the strut graft in thoracolumbar instrumentation testing. Clin Biomech (Bristol, Avon) (2003) 0.84

Articles by these authors

Shear movement at the fracture site delays healing in a diaphyseal fracture model. J Orthop Res (2003) 2.03

Review of existing grading systems for cervical or lumbar disc and facet joint degeneration. Eur Spine J (2005) 1.90

Cardiopulmonary, histological, and inflammatory alterations after lung contusion in a novel mouse model of blunt chest trauma. Shock (2003) 1.78

Pulmonary contusion causes impairment of macrophage and lymphocyte immune functions and increases mortality associated with a subsequent septic challenge. Crit Care Med (2005) 1.65

Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: Part I. Lumbar spine. Eur Spine J (2005) 1.52

Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine (Phila Pa 1976) (2002) 1.50

Metaphyseal fracture healing in a sheep model of low turnover osteoporosis induced by hypothalamic-pituitary disconnection (HPD). J Orthop Res (2013) 1.42

Signal transduction pathways involved in mechanotransduction in bone cells. Biochem Biophys Res Commun (2006) 1.40

In vitro flexibility of the cervical spine after ventral uncoforaminotomy. Laboratory investigation. J Neurosurg Spine (2007) 1.37

Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis. Bone (2005) 1.33

Injuries of the cervical spine in patients with ankylosing spondylitis: experience at two trauma centers. J Neurosurg Spine (2006) 1.23

Refining animal models in fracture research: seeking consensus in optimising both animal welfare and scientific validity for appropriate biomedical use. BMC Musculoskelet Disord (2007) 1.20

Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method. J Biomech (2005) 1.20

Mechanics and mechano-biology of fracture healing in normal and osteoporotic bone. Osteoporos Int (2004) 1.20

Buruli ulcer: a systemic disease. Clin Infect Dis (2003) 1.16

Is a collagen scaffold for a tissue engineered nucleus replacement capable of restoring disc height and stability in an animal model? Eur Spine J (2006) 1.15

Proliferation of human-derived osteoblast-like cells depends on the cycle number and frequency of uniaxial strain. J Biomech (2002) 1.15

Pedicle screws enhance primary stability in multilevel cervical corpectomies: biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instumentations. Spine (Phila Pa 1976) (2003) 1.14

Clinical results for minimally invasive locked plating of proximal humerus fractures. J Orthop Trauma (2010) 1.14

Does computer-assisted spine surgery reduce intraoperative radiation doses? Spine (Phila Pa 1976) (2006) 1.13

Fracture healing in mice under controlled rigid and flexible conditions using an adjustable external fixator. J Orthop Res (2010) 1.12

Bone formation in a long bone defect model using a platelet-rich plasma-loaded collagen scaffold. Biomaterials (2005) 1.11

Intradiscal pressure measurements in normal discs, compressed discs and compressed discs treated with axial posterior disc distraction: an experimental study on the rabbit lumbar spine model. Eur Spine J (2005) 1.11

Stepwise reduction of functional spinal structures increase range of motion and change lordosis angle. J Biomech (2006) 1.10

Determination of trunk muscle forces for flexion and extension by using a validated finite element model of the lumbar spine and measured in vivo data. J Biomech (2005) 1.08

Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus. Clin Biomech (Bristol, Avon) (2006) 1.07

Early orthogeriatric treatment of trauma in the elderly: a systematic review and metaanalysis. Dtsch Arztebl Int (2013) 1.07

Valid micro finite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions. J Biomech (2010) 1.07

Biomechanical evaluation of conventional anulus fibrosus closure methods required for nucleus replacement. Laboratory investigation. J Neurosurg Spine (2008) 1.06

Experimental blunt chest trauma impairs fracture healing in rats. J Orthop Res (2010) 1.05

Validity and interobserver agreement of a new radiographic grading system for intervertebral disc degeneration: Part II. Cervical spine. Eur Spine J (2006) 1.05

Second generation locked plating of proximal humerus fractures--a prospective multicentre observational study. Int Orthop (2010) 1.05

Primary stability and strain distribution of cementless hip stems as a function of implant design. Clin Biomech (Bristol, Avon) (2011) 1.04

Nonsteroidal anti-inflammatory drugs (NSAIDs) in the perioperative phase in traumatology and orthopedics effects on bone healing. Oper Orthop Traumatol (2005) 1.04

Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment. Clin Biomech (Bristol, Avon) (2007) 1.04

Intradiscal pressure, shear strain, and fiber strain in the intervertebral disc under combined loading. Spine (Phila Pa 1976) (2007) 1.03

The anaphylatoxin receptor C5aR is present during fracture healing in rats and mediates osteoblast migration in vitro. J Trauma (2011) 1.03

Preliminary investigations on intradiscal pressures during daily activities: an in vivo study using the merino sheep. PLoS One (2013) 1.02

A three-dimensional collagen matrix as a suitable culture system for the comparison of cyclic strain and hydrostatic pressure effects on intervertebral disc cells. J Neurosurg Spine (2005) 1.01

Regulation of gene expression in intervertebral disc cells by low and high hydrostatic pressure. Eur Spine J (2006) 1.01

Internal loads in the human tibia during gait. Clin Biomech (Bristol, Avon) (2009) 1.00

Passive muscle stiffness may be influenced by active contractility of intramuscular connective tissue. Med Hypotheses (2005) 1.00

Long-term results for the uncemented Zweymuller/Alloclassic hip endoprosthesis. A 15-year minimum follow-up of 320 hip operations. J Arthroplasty (2008) 1.00

Minimally invasive ventral spondylodesis for thoracolumbar fracture treatment: surgical technique and first clinical outcome. Eur Spine J (2003) 0.99

Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. Clin Biomech (Bristol, Avon) (2002) 0.99

A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma (2002) 0.98

Pedicle screw loosening: a clinically relevant complication? Eur Spine J (2015) 0.98

The relation between intervertebral disc bulging and annular fiber associated strains for simple and complex loading. J Biomech (2008) 0.97

The effect of different design concepts in lumbar total disc arthroplasty on the range of motion, facet joint forces and instantaneous center of rotation of a L4-5 segment. Eur Spine J (2009) 0.97

A new porcine in vivo animal model of disc degeneration: response of anulus fibrosus cells, chondrocyte-like nucleus pulposus cells, and notochordal nucleus pulposus cells to partial nucleotomy. Spine (Phila Pa 1976) (2009) 0.97

The pattern of preformed cytokines in tissues frequently affected by blunt trauma. Shock (2003) 0.97

The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping. Eur Spine J (2010) 0.97

Minimally invasive application of the non-contact-bridging (NCB) plate to the proximal humerus: an anatomical study. J Orthop Trauma (2007) 0.96

In vitro stabilizing effect of a transforaminal compared with two posterior lumbar interbody fusion cages. Spine (Phila Pa 1976) (2005) 0.96

The effectiveness of physiotherapy after operative treatment of supracondylar humeral fractures in children. J Pediatr Orthop (2005) 0.96

Limitations of the cervical porcine spine in evaluating spinal implants in comparison with human cervical spinal segments: a biomechanical in vitro comparison of porcine and human cervical spine specimens with different instrumentation techniques. Spine (Phila Pa 1976) (2005) 0.95

Grading of degenerative disk disease and functional impairment: imaging versus patho-anatomical findings. Eur Spine J (2008) 0.95

The relation between the instantaneous center of rotation and facet joint forces - A finite element analysis. Clin Biomech (Bristol, Avon) (2007) 0.95

Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic. J Biomech (2005) 0.95

Ageing and degenerative changes of the intervertebral disc and their impact on spinal flexibility. Eur Spine J (2014) 0.94

Biochemical characterization of individual injury pattern and injury severity. Injury (2003) 0.94

Mechanical characterization of external fixator stiffness for a rat femoral fracture model. J Orthop Res (2009) 0.94

Comparison of four methods to simulate swelling in poroelastic finite element models of intervertebral discs. J Mech Behav Biomed Mater (2011) 0.93

Cervical spine disc prosthesis: radiographic, biomechanical and morphological post mortal findings 12 weeks after implantation. A retrieval example. Eur Spine J (2007) 0.93

Rehydration of vertebral trabecular bone: influences on its anisotropy, its stiffness and the indentation work with a view to age, gender and vertebral level. Bone (2009) 0.93

Which axial and bending stiffnesses of posterior implants are required to design a flexible lumbar stabilization system? J Biomech (2008) 0.93

The mechanical response of the lumbar spine to different combinations of disc degenerative changes investigated using randomized poroelastic finite element models. Eur Spine J (2010) 0.92

Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res (2004) 0.91

Response analysis of the lumbar spine during regular daily activities--a finite element analysis. J Biomech (2010) 0.91

Hydrogels for nucleus replacement--facing the biomechanical challenge. J Mech Behav Biomed Mater (2012) 0.91

Glucocorticoid treatment of ovariectomized sheep affects mineral density, structure, and mechanical properties of cancellous bone. J Bone Miner Res (2003) 0.91

Ankle arthrodesis using Ilizarov ring fixators: a review of 22 cases. Foot Ankle Int (2006) 0.90

Effects of diclofenac on periosteal callus maturation in osteotomy healing in an animal model. Arch Orthop Trauma Surg (2006) 0.90

Limb malalignment and functional outcome after antegrade versus retrograde intramedullary nailing in distal femoral fractures. J Trauma (2006) 0.90

Solvent-preserved, bovine cancellous bone blocks used for reconstruction of thoracolumbar fractures in minimally invasive spinal surgery-first clinical results. Eur Spine J (2004) 0.90

Geometry strongly influences the response of numerical models of the lumbar spine--a probabilistic finite element analysis. J Biomech (2012) 0.90

Inhibition of cortical and cancellous bone formation in glucocorticoid-treated OVX sheep. Bone (2005) 0.90

Stepwise reduction of functional spinal structures increase disc bulge and surface strains. J Biomech (2008) 0.90

Stepwise reduction of functional spinal structures increase vertebral translation and intradiscal pressure. J Biomech (2006) 0.89