Visualization of tensor fields using superquadric glyphs.

PubWeight™: 1.07‹?› | Rank: Top 10%

🔗 View Article (PMC 2169197)

Published in Magn Reson Med on January 01, 2005

Authors

Daniel B Ennis1, Gordon Kindlman, Ignacio Rodriguez, Patrick A Helm, Elliot R McVeigh

Author Affiliations

1: National Institutes of Health, National Heart, Lung, and Blood Institute, Bethesda, Maryland, USA. dbe@stanford.edu

Articles cited by this

Estimation of the effective self-diffusion tensor from the NMR spin echo. J Magn Reson B (1994) 18.37

Toward a quantitative assessment of diffusion anisotropy. Magn Reson Med (1996) 10.50

Diffusion tensor MR imaging of the human brain. Radiology (1996) 9.84

Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn Reson Med (1999) 8.94

High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity. Magn Reson Med (2002) 8.89

Inferring microstructural features and the physiological state of tissues from diffusion-weighted images. NMR Biomed (1996) 7.70

Fiber orientation in the canine left ventricle during diastole and systole. Circ Res (1969) 7.01

Laminar structure of the heart: ventricular myocyte arrangement and connective tissue architecture in the dog. Am J Physiol (1995) 4.08

Color schemes to represent the orientation of anisotropic tissues from diffusion tensor data: application to white matter fiber tract mapping in the human brain. Magn Reson Med (1999) 3.89

DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. J Magn Reson (1999) 3.77

Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging. Am J Physiol (1998) 2.97

Three-dimensional systolic strain patterns in the normal human left ventricle: characterization with tagged MR imaging. Radiology (2000) 2.63

Transverse shear along myocardial cleavage planes provides a mechanism for normal systolic wall thickening. Circ Res (1995) 1.94

Relation between transmural deformation and local myofiber direction in canine left ventricle. Circ Res (1988) 1.81

Minimal gradient encoding for robust estimation of diffusion anisotropy. Magn Reson Imaging (2000) 1.42

Diffusion tensor microscopy of the intervertebral disc anulus fibrosus. Magn Reson Med (1999) 1.37

Comparison of scalar measures used in magnetic resonance diffusion tensor imaging. J Magn Reson (1999) 0.82

Articles by these authors

Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement. Magn Reson Med (2002) 4.95

Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med (2005) 4.32

Self-gated cardiac cine MRI. Magn Reson Med (2004) 2.97

T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo. Magn Reson Med (2007) 2.78

Serial cardiac magnetic resonance imaging of injected mesenchymal stem cells. Circulation (2003) 2.75

Transmural dispersion of myofiber mechanics: implications for electrical heterogeneity in vivo. J Am Coll Cardiol (2007) 2.44

Displacement and velocity of the coronary arteries: cardiac and respiratory motion. IEEE Trans Med Imaging (2006) 2.38

Technology preview: X-ray fused with magnetic resonance during invasive cardiovascular procedures. Catheter Cardiovasc Interv (2007) 2.12

Catheter-based endomyocardial injection with real-time magnetic resonance imaging. Circulation (2002) 2.08

Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model. Circulation (2006) 2.00

Endoventricular patch plasty for dyskinetic anteroapical left ventricular aneurysm increases systolic circumferential shortening in sheep. J Thorac Cardiovasc Surg (2007) 1.88

Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD. Magn Reson Med (2003) 1.84

Analysis of Cardiac Function from MR Images. IEEE Comput Graph Appl (1997) 1.82

Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in Swine. Circulation (2003) 1.78

Model of reentrant ventricular tachycardia based on infarct border zone geometry predicts reentrant circuit features as determined by activation mapping. Heart Rhythm (2007) 1.76

Collagen-targeted MRI contrast agent for molecular imaging of fibrosis. Angew Chem Int Ed Engl (2007) 1.75

System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner. Magn Reson Med (2004) 1.71

Ex vivo 3D diffusion tensor imaging and quantification of cardiac laminar structure. Magn Reson Med (2005) 1.68

Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med (2003) 1.68

Assessing proarrhythmic potential of drugs when optimal studies are infeasible. Am Heart J (2009) 1.66

Novel technique for cardiac electromechanical mapping with magnetic resonance imaging tagging and an epicardial electrode sock. Ann Biomed Eng (2003) 1.60

Magnetic resonance-based anatomical analysis of scar-related ventricular tachycardia: implications for catheter ablation. Circ Res (2007) 1.58

Three-dimensional mapping of optimal left ventricular pacing site for cardiac resynchronization. Circulation (2007) 1.56

A computational framework for the statistical analysis of cardiac diffusion tensors: application to a small database of canine hearts. IEEE Trans Med Imaging (2007) 1.53

Regional alterations in protein expression in the dyssynchronous failing heart. Circulation (2003) 1.49

Interventional cardiovascular procedures guided by real-time MR imaging: an interactive interface using multiple slices, adaptive projection modes and live 3D renderings. J Magn Reson Imaging (2007) 1.46

Real-time volume rendered MRI for interventional guidance. J Cardiovasc Magn Reson (2002) 1.45

Motion corrected free-breathing delayed-enhancement imaging of myocardial infarction using nonrigid registration. J Magn Reson Imaging (2007) 1.44

Respiratory motion of the heart from free breathing coronary angiograms. IEEE Trans Med Imaging (2004) 1.42

Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging. Magn Reson Med (2008) 1.38

Effects of single- and biventricular pacing on temporal and spatial dynamics of ventricular contraction. Am J Physiol Heart Circ Physiol (2002) 1.33

Motion-corrected free-breathing delayed enhancement imaging of myocardial infarction. Magn Reson Med (2005) 1.32

High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med (2009) 1.29

Electromechanical analysis of infarct border zone in chronic myocardial infarction. Am J Physiol Heart Circ Physiol (2005) 1.27

Multi-parameter in vivo cardiac magnetic resonance imaging demonstrates normal perfusion reserve despite severely attenuated beta-adrenergic functional response in neuronal nitric oxide synthase knockout mice. Eur Heart J (2007) 1.26

X-ray fused with magnetic resonance imaging (XFM) to target endomyocardial injections: validation in a swine model of myocardial infarction. Circulation (2006) 1.23

Computational cardiac anatomy using MRI. Magn Reson Med (2004) 1.23

Real-time volumetric flow measurements with complex-difference MRI. Magn Reson Med (2003) 1.20

Antegrade percutaneous closure of membranous ventricular septal defect using X-ray fused with magnetic resonance imaging. JACC Cardiovasc Interv (2009) 1.19

Three-dimensional motion tracking of coronary arteries in biplane cineangiograms. IEEE Trans Med Imaging (2003) 1.15

Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views. Magn Reson Med (2003) 1.15

The effect of anteroapical aneurysm plication on end-systolic three-dimensional strain in the sheep: a magnetic resonance imaging tagging study. J Thorac Cardiovasc Surg (2006) 1.15

Flow-gated phase-contrast MRI using radial acquisitions. Magn Reson Med (2004) 1.13

Measurement of skeletal muscle perfusion during postischemic reactive hyperemia using contrast-enhanced MRI with a step-input function. Magn Reson Med (2005) 1.12

Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine. J Am Coll Cardiol (2005) 1.12

The visceral pericardium: macromolecular structure and contribution to passive mechanical properties of the left ventricle. Am J Physiol Heart Circ Physiol (2007) 1.12

Assessment of regional systolic and diastolic dysfunction in familial hypertrophic cardiomyopathy using MR tagging. Magn Reson Med (2003) 1.12

Characterization of peri-infarct zone heterogeneity by contrast-enhanced multidetector computed tomography: a comparison with magnetic resonance imaging. J Am Coll Cardiol (2009) 1.10

Endocardial versus epicardial electrical synchrony during LV free-wall pacing. Am J Physiol Heart Circ Physiol (2003) 1.09

3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI. J Magn Reson Imaging (2004) 1.08

Rest period duration of the coronary arteries: implications for magnetic resonance coronary angiography. Med Phys (2005) 1.07

Balanced multipoint displacement encoding for DENSE MRI. Magn Reson Med (2009) 1.07

Spectrally selective B1-insensitive T2 magnetization preparation sequence. Magn Reson Med (2009) 1.06

Imaging two-dimensional displacements and strains in skeletal muscle during joint motion by cine DENSE MR. J Biomech (2008) 1.05

High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession. Magn Reson Med (2002) 1.05

Estimating Motion From MRI Data. Proc IEEE Inst Electr Electron Eng (2003) 1.04

Minimizing RF heating of conducting wires in MRI. Magn Reson Med (2007) 1.03

Beating heart aortic valve replacement using real-time MRI guidance. Innovations (Phila) (2007) 1.03

Real-time MRI guided atrial septal puncture and balloon septostomy in swine. Catheter Cardiovasc Interv (2006) 1.02

A new method for cardiac computed tomography regional function assessment: stretch quantifier for endocardial engraved zones (SQUEEZ). Circ Cardiovasc Imaging (2012) 1.02

Fast measurement of intracardiac pressure differences with 2D breath-hold phase-contrast MRI. Magn Reson Med (2003) 1.01

Mitral cerclage annuloplasty, a novel transcatheter treatment for secondary mitral valve regurgitation: initial results in swine. J Am Coll Cardiol (2009) 0.98

Methodologies to characterize the QT/corrected QT interval in the presence of drug-induced heart rate changes or other autonomic effects. Am Heart J (2012) 0.98

Torsion of the left ventricle during pacing with MRI tagging. J Cardiovasc Magn Reson (2003) 0.97

Multi-contrast delayed enhancement provides improved contrast between myocardial infarction and blood pool. J Magn Reson Imaging (2005) 0.97

Descriptive review of current NMR-based metabolomic data analysis packages. Prog Nucl Magn Reson Spectrosc (2011) 0.96

Timing of depolarization and contraction in the paced canine left ventricle: model and experiment. J Cardiovasc Electrophysiol (2003) 0.95

Myocardial tagging with SSFP. Magn Reson Med (2003) 0.95

A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system. Med Phys (2008) 0.94

High temporal resolution phase contrast MRI with multiecho acquisitions. Magn Reson Med (2002) 0.93

T2* measurement during first-pass contrast-enhanced cardiac perfusion imaging. Magn Reson Med (2006) 0.93

The evaluation and management of drug effects on cardiac conduction (PR and QRS intervals) in clinical development. Am Heart J (2013) 0.92

In vitro release of vascular endothelial growth factor from gadolinium-doped biodegradable microspheres. Magn Reson Med (2004) 0.92

Unsupervised estimation of myocardial displacement from tagged MR sequences using nonrigid registration. Magn Reson Med (2008) 0.92

Measurement of kinetic parameters in skeletal muscle by magnetic resonance imaging with an intravascular agent. Magn Reson Med (2006) 0.91

Real-time blood flow imaging using autocalibrated spiral sensitivity encoding. Magn Reson Med (2005) 0.90

Automatic tuning and matching of a small multifrequency saddle coil at 4.7 T. Magn Reson Med (2004) 0.90

Phased array ghost elimination (PAGE) for segmented SSFP imaging with interrupted steady-state. Magn Reson Med (2002) 0.89

MR-guided sclerotherapy of low-flow vascular malformations using T2 -weighted interrupted bSSFP (T2 W-iSSFP): comparison of pulse sequences for visualization and needle guidance. J Magn Reson Imaging (2014) 0.88

Computer-assisted enhanced volumetric segmentation magnetic resonance imaging data using a mixture of artificial neural networks. Magn Reson Imaging (2003) 0.88

Construction of 3D MR image-based computer models of pathologic hearts, augmented with histology and optical fluorescence imaging to characterize action potential propagation. Med Image Anal (2011) 0.88

Phased array ghost elimination. NMR Biomed (2006) 0.88

The predictive value of 53BP1 and BRCA1 mRNA expression in advanced non-small-cell lung cancer patients treated with first-line platinum-based chemotherapy. Oncotarget (2013) 0.88

Brachytherapy for the treatment of recurrent prostate cancer after radiotherapy or radical prostatectomy. BJU Int (2012) 0.88

Cardiorespiratory-resolved magnetic resonance imaging: measuring respiratory modulation of cardiac function. Magn Reson Med (2006) 0.87

Multishot EPI-SSFP in the heart. Magn Reson Med (2002) 0.87

Troponin measurements during drug development--considerations for monitoring and management of potential cardiotoxicity: an educational collaboration among the Cardiac Safety Research Consortium, the Duke Clinical Research Institute, and the US Food and Drug Administration. Am Heart J (2011) 0.86

High-resolution 3D arteriography of chronic total peripheral occlusions using a T1-W turbo spin-echo sequence with inner-volume imaging. Magn Reson Med (2007) 0.86

Simultaneous imaging of myocardial motion and chamber blood flow with SPAMM n' EGGS (Spatial Modulation of Magnetization With Encoded Gradients for Gauging Speed). J Magn Reson Imaging (2008) 0.86

Multimodality cardiovascular molecular imaging technology. J Nucl Med (2010) 0.86

The Cardiac Safety Research Consortium electrocardiogram warehouse: thorough QT database specifications and principles of use for algorithm development and testing. Am Heart J (2010) 0.85

Visualization of active devices and automatic slice repositioning ("SnapTo") for MRI-guided interventions. Magn Reson Med (2010) 0.85

Real-time magnetic resonance imaging guidance for cardiovascular procedures. Semin Thorac Cardiovasc Surg (2007) 0.85

Regional cardiac function assessment in 4D CT: comparison between SQUEEZ and ejection fraction. Conf Proc IEEE Eng Med Biol Soc (2012) 0.84

Assessment of ovarian vascularization in the polycystic ovary by three-dimensional power Doppler ultrasonography. Gynecol Endocrinol (2008) 0.83

Geodesic based registration of sensor data and anatomical surface image data. Ann Biomed Eng (2007) 0.83

Model of bipolar electrogram fractionation and conduction block associated with activation wavefront direction at infarct border zone lateral isthmus boundaries. Circ Arrhythm Electrophysiol (2014) 0.82

Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view. Magn Reson Med (2004) 0.82