Vertebroplasty versus kyphoplasty: biomechanical behavior under repetitive loading conditions.

PubWeight™: 1.10‹?› | Rank: Top 10%

🔗 View Article (PMID 16915092)

Published in Spine (Phila Pa 1976) on August 15, 2006

Authors

Mi Jung Kim1, Derek P Lindsey, Matthew Hannibal, Todd F Alamin

Author Affiliations

1: Department of Physical Medicine and Rehabilitation, Hanyang University, Seoul, Korea.

Articles citing this

Recompression of vertebral body after balloon kyphoplasty for osteoporotic vertebral compression fracture. Eur Spine J (2010) 1.25

Balloon kyphoplasty and vertebroplasty in the management of vertebral compression fractures. Osteoporos Int (2011) 1.11

Comparison of unipedicular and bipedicular kyphoplasty on the stiffness and biomechanical balance of compression fractured vertebrae. Eur Spine J (2011) 1.07

Vertebroplasty and Kyphoplasty Can Restore Normal Spine Mechanics following Osteoporotic Vertebral Fracture. J Osteoporos (2010) 0.93

Vertebroplasty and kyphoplasty: a comparative review of efficacy and adverse events. Curr Rev Musculoskelet Med (2008) 0.90

Height restoration and wedge angle correction effects of percutaneous vertebroplasty: association with intraosseous clefts. Eur Radiol (2011) 0.88

Incidence and risk factors for early adjacent vertebral fractures after balloon kyphoplasty for osteoporotic fractures: analysis of the SWISSspine registry. Eur Spine J (2013) 0.86

Radiofrequency-targeted vertebral augmentation versus traditional balloon kyphoplasty: radiographic and morphologic outcomes of an ex vivo biomechanical pilot study. Clin Interv Aging (2012) 0.86

Refracture of osteoporotic vertebral body concurrent with cement fragmentation at the previously treated vertebral level after balloon kyphoplasty: a case report. Osteoporos Int (2014) 0.83

Outcome of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fracture in patients with rheumatoid arthritis. BMC Musculoskelet Disord (2016) 0.80

Vertebroplasty with self-locking hexagonal metal implants shows comparable primary and secondary stiffness to PMMA cement augmentation techniques in a biomechanical vertebral compression fracture model. Eur Spine J (2010) 0.79

Comparison of kyphoplasty and lordoplasty in the treatment of osteoporotic vertebral compression fracture. Asian Spine J (2010) 0.79

Safety and Efficacy Studies of Vertebroplasty, Kyphoplasty, and Mesh-Container-Plasty for the Treatment of Vertebral Compression Fractures: Preliminary Report. PLoS One (2016) 0.77

Percutaneous Dorsal Instrumentation of Vertebral Burst Fractures: Value of Additional Percutaneous Intravertebral Reposition-Cadaver Study. Biomed Res Int (2015) 0.75

Update of vertebral cementoplasty in porotic patients. Interv Neuroradiol (2015) 0.75

Bone cement distribution in the vertebral body affects chances of recompression after percutaneous vertebroplasty treatment in elderly patients with osteoporotic vertebral compression fractures. Clin Interv Aging (2017) 0.75

Vertebral augmentation by kyphoplasty and vertebroplasty: 8 years experience outcomes and complications. J Craniovertebr Junction Spine (2016) 0.75

Risk factors of recompression of cemented vertebrae after kyphoplasty for osteoporotic vertebral compression fractures. Int Orthop (2016) 0.75

Jack vertebral dilator kyphoplasty for treatment of osteoporotic vertebral compression fractures. Eur J Orthop Surg Traumatol (2012) 0.75

Articles by these authors

The effects of an interspinous implant on intervertebral disc pressures. Spine (Phila Pa 1976) (2003) 2.76

The treatment mechanism of an interspinous process implant for lumbar neurogenic intermittent claudication. Spine (Phila Pa 1976) (2005) 1.97

Interspinous process decompression with the X-STOP device for lumbar spinal stenosis: a 4-year follow-up study. J Spinal Disord Tech (2006) 1.61

Discographic, MRI and psychosocial determinants of low back pain disability and remission: a prospective study in subjects with benign persistent back pain. Spine J (2005) 1.59

The effect of an interspinous process implant on facet loading during extension. Spine (Phila Pa 1976) (2005) 1.58

Gunshot wounds to the spine: literature review and report on a migratory intrathecal bullet. Am J Orthop (Belle Mead NJ) (2008) 1.57

Flexor tendon tissue engineering: acellularized and reseeded tendon constructs. Plast Reconstr Surg (2009) 1.53

A prospective controlled study of limited versus subtotal posterior discectomy: short-term outcomes in patients with herniated lumbar intervertebral discs and large posterior anular defect. Spine (Phila Pa 1976) (2006) 1.51

A novel technique of intra-spinous process injection of PMMA to augment the strength of an inter-spinous process device such as the X STOP. Spine (Phila Pa 1976) (2008) 1.48

Provocative discography in volunteer subjects with mild persistent low back pain. Spine J (2003) 1.48

Osteochondral lesions of the talus: effect of defect size and plantarflexion angle on ankle joint stresses. Am J Sports Med (2012) 1.44

Bacteriologic culture of excised intervertebral disc from immunocompetent patients undergoing single level primary lumbar microdiscectomy. J Spinal Disord Tech (2011) 1.24

Capsaicin-sensitive sensory neurons contribute to the maintenance of trabecular bone integrity. J Bone Miner Res (2004) 1.22

Effects of creep and cyclic loading on the mechanical properties and failure of human Achilles tendons. Ann Biomed Eng (2003) 1.20

Effects of hydrostatic pressure and transforming growth factor-beta 3 on adult human mesenchymal stem cell chondrogenesis in vitro. Tissue Eng (2006) 1.17

A quantitative assessment of the insertional footprints of the hip joint capsular ligaments and their spanning fibers for reconstruction. Clin Anat (2013) 1.12

Hydrostatic pressure enhances chondrogenic differentiation of human bone marrow stromal cells in osteochondrogenic medium. Ann Biomed Eng (2008) 1.07

An anatomic arthroscopic description of the hip capsular ligaments for the hip arthroscopist. Arthroscopy (2011) 1.06

The proximal hip joint capsule and the zona orbicularis contribute to hip joint stability in distraction. J Orthop Res (2009) 1.05

Diagnostic evaluation of low back pain. Orthop Clin North Am (2004) 1.05

The use of an interspinous implant in conjunction with a graded facetectomy procedure. Spine (Phila Pa 1976) (2005) 1.04

Pectoralis major tendon rupture: a biomechanical analysis of repair techniques. J Orthop Res (2011) 1.00

Failure strength of lumbar spinous processes loaded in a tension band model. J Neurosurg Spine (2012) 0.99

Dose- and time-dependent effects of cyclic hydrostatic pressure on transforming growth factor-beta3-induced chondrogenesis by adult human mesenchymal stem cells in vitro. Tissue Eng (2006) 0.99

Strains across the acetabular labrum during hip motion: a cadaveric model. Am J Sports Med (2011) 0.95

Low-pressure positive Discography in subjects asymptomatic of significant low back pain illness. Spine (Phila Pa 1976) (2006) 0.95

Trapezium trabecular morphology in carpometacarpal arthritis. J Hand Surg Am (2012) 0.94

Mechanobiology of mandibular distraction osteogenesis: experimental analyses with a rat model. Bone (2004) 0.91

The monotonic and fatigue properties of osteoporotic thoracic vertebral bodies. Spine (Phila Pa 1976) (2005) 0.90

Insertion loads of the X STOP interspinous process distraction system designed to treat neurogenic intermittent claudication. Eur Spine J (2005) 0.90

Bone microstructure and its associated genetic variability in 12 inbred mouse strains: microCT study and in silico genome scan. Bone (2007) 0.90

Flexor tendon tissue engineering: bioreactor cyclic strain increases construct strength. Tissue Eng Part A (2010) 0.89

Posterior stabilization at the cervicothoracic junction: a biomechanical study. Spine (Phila Pa 1976) (2002) 0.89

Distal biceps tendon repair: a biomechanical comparison of intact tendon and 2 repair techniques. Am J Sports Med (2006) 0.89

The effect of relaxin on the female anterior cruciate ligament: Analysis of mechanical properties in an animal model. Knee (2008) 0.88

In vitro analysis of peri-articular soft tissues passive constraining effect on hip kinematics and joint stability. Knee Surg Sports Traumatol Arthrosc (2012) 0.87

New resource for the computation of cartilage biphasic material properties with the interpolant response surface method. Comput Methods Biomech Biomed Engin (2009) 0.85

Biomechanical testing of epitenon suture strength in Achilles tendon repairs. Foot Ankle Int (2007) 0.83

Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis. J Orthop Surg Res (2010) 0.82

Bone cement improves suture anchor fixation. Clin Orthop Relat Res (2006) 0.82

Biomechanical evaluation of a 1-stage revision anterior cruciate ligament reconstruction technique using a structural bone void filler for femoral fixation. Arthroscopy (2009) 0.81

Deriving tissue density and elastic modulus from microCT bone scans. Bone (2011) 0.80

Measurement of in vivo lumbar intervertebral disc pressure during spinal manipulation: a feasibility study. J Appl Biomech (2006) 0.80

Gene regulation ex vivo within a wrap-around tendon. Tissue Eng (2006) 0.79

Bioabsorbable tricalcium phosphate bone cement strengthens fixation of suture anchors. Clin Orthop Relat Res (2010) 0.79

The effect of implant placement on sacroiliac joint range of motion: posterior versus transarticular. Spine (Phila Pa 1976) (2015) 0.79

A viscoelastic constitutive model can accurately represent entire creep indentation tests of human patella cartilage. J Appl Biomech (2012) 0.78

Gluteal-sparing approach for posterior iliac crest bone graft: description of a new technique and assessment of morbidity in ninety-two patients after spinal fusion. Spine (Phila Pa 1976) (2010) 0.78

Decellularized tendon-bone composite grafts for extremity reconstruction: an experimental study. Plast Reconstr Surg (2014) 0.78

Biomechanical comparison of the simple running and cross-stitch epitenon sutures in achilles tendon repairs. Foot Ankle Int (2008) 0.78

Biomechanical evaluation of a novel reverse coracoacromial ligament reconstruction for acromioclavicular joint separation. Am J Sports Med (2011) 0.77

Locked versus nonlocked plate fixation for first metatarsophalangeal arthrodesis: a biomechanical investigation. Foot Ankle Int (2012) 0.77

Effects of tensile strain and fluid flow on osteoarthritic human chondrocyte metabolism in vitro. J Orthop Res (2010) 0.77

Evaluation of a one-stage ACL revision technique using bone void filler after cyclic loading. Knee (2011) 0.77

Parametric and cadaveric models of lumbar flexion instability and flexion restricting dynamic stabilization system. Eur Spine J (2013) 0.75

Two ulnar collateral ligament reconstruction methods: the docking technique versus bioabsorbable interference screw fixation--a biomechanical evaluation with cyclic loading. J Shoulder Elbow Surg (2007) 0.75

Lumbar intersegmental spacing and angulation in the modified lateral decubitus position versus variants of prone positioning. Spine J (2009) 0.75

Biomechanical comparison of blade plate and intramedullary nail fixation for tibiocalcaneal arthrodesis. Foot Ankle Int (2010) 0.75

Compressive preload reduces segmental flexion instability after progressive destabilization of the lumbar spine. Spine (Phila Pa 1976) (2014) 0.75

Comparison of initial compression force across the subtalar joint by two different screw fixation techniques. J Foot Ankle Surg (2006) 0.75

Replicating a Colles fracture in an excised radius: revisiting testing protocols. J Biomech (2012) 0.75

An analysis of four ulnar collateral ligament reconstruction procedures with cyclic valgus loading. J Shoulder Elbow Surg (2008) 0.75

The X STOP Interspinous Process Decompression versus Laminectomy for Treatment of Lumbar Spinal Stenosis: Economic Analysis 816. Neurosurgery (2006) 0.75