Quantitative characterization of myocardial infarction by cardiovascular magnetic resonance predicts future cardiovascular events in patients with ischemic cardiomyopathy.

PubWeight™: 0.97‹?› | Rank: Top 15%

🔗 View Article (PMC 2322993)

Published in J Cardiovasc Magn Reson on April 09, 2008

Authors

Hajime Yokota1, Shahriar Heidary, Chandra K Katikireddy, Patricia Nguyen, John M Pauly, Michael V McConnell, Phillip C Yang

Author Affiliations

1: Division of cardiovascular medicine, department of medicine, Stanford university, Stanford, CA, USA. hy14861114@yahoo.co.jp

Articles citing this

Late gadolinium enhancement on cardiac magnetic resonance predicts adverse cardiovascular outcomes in nonischemic cardiomyopathy: a systematic review and meta-analysis. Circ Cardiovasc Imaging (2013) 1.29

The Selvester QRS Score is more accurate than Q waves and fragmented QRS complexes using the Mason-Likar configuration in estimating infarct volume in patients with ischemic cardiomyopathy. J Electrocardiol (2010) 0.94

Scar extent evaluated by late gadolinium enhancement CMR: a powerful predictor of long term appropriate ICD therapy in patients with coronary artery disease. J Cardiovasc Magn Reson (2013) 0.90

Enhancing retention and efficacy of cardiosphere-derived cells administered after myocardial infarction using a hyaluronan-gelatin hydrogel. Biomatter (2013) 0.85

Myocardial scar extent evaluated by cardiac magnetic resonance imaging in ICD patients: relationship to spontaneous VT during long-term follow-up. Int J Cardiovasc Imaging (2010) 0.84

Established and emerging cardiovascular magnetic resonance techniques for the assessment of stable coronary heart disease and acute coronary syndromes. Quant Imaging Med Surg (2014) 0.83

Nocturnal Blood Pressure Pattern Affects Left Ventricular Remodeling and Late Gadolinium Enhancement in Patients with Hypertension and Left Ventricular Hypertrophy. PLoS One (2013) 0.81

The role of cardiac magnetic resonance in the evaluation of patients presenting with suspected or confirmed acute coronary syndrome. Cardiol Res Pract (2011) 0.77

Infarct tissue characterization in implantable cardioverter-defibrillator recipients for primary versus secondary prevention following myocardial infarction: a study with contrast-enhancement cardiovascular magnetic resonance imaging. Int J Cardiovasc Imaging (2012) 0.75

Assessment of myocardial infarction by cardiac magnetic resonance imaging and long-term mortality. Arq Bras Cardiol (2014) 0.75

Apelin-13 infusion salvages the peri-infarct region to preserve cardiac function after severe myocardial injury. Int J Cardiol (2016) 0.75

Review of Journal of Cardiovascular Magnetic Resonance 2009. J Cardiovasc Magn Reson (2010) 0.75

The Role of Cardiovascular Magnetic Resonance Imaging in Heart Failure. Card Fail Rev (2016) 0.75

Articles cited by this

The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction. N Engl J Med (2000) 13.25

Sudden death due to cardiac arrhythmias. N Engl J Med (2001) 6.72

Characterization of the peri-infarct zone by contrast-enhanced cardiac magnetic resonance imaging is a powerful predictor of post-myocardial infarction mortality. Circulation (2006) 4.98

Delayed enhancement cardiovascular magnetic resonance assessment of non-ischaemic cardiomyopathies. Eur Heart J (2005) 4.62

Prognostic significance of microvascular obstruction by magnetic resonance imaging in patients with acute myocardial infarction. Circulation (1998) 4.54

Infarct morphology identifies patients with substrate for sustained ventricular tachycardia. J Am Coll Cardiol (2005) 2.80

Left ventricular remodeling and ventricular arrhythmias after myocardial infarction. Circulation (2003) 2.03

Long-term survival of medically treated patients in the Coronary Artery Surgery Study (CASS) Registry. Circulation (1994) 1.86

Surgical coronary revascularization in survivors of prehospital cardiac arrest: its effect on inducible ventricular arrhythmias and long-term survival. J Am Coll Cardiol (1990) 1.73

Coronary artery revascularization in patients with sustained ventricular arrhythmias in the chronic phase of a myocardial infarction: effects on the electrophysiologic substrate and outcome. J Am Coll Cardiol (2001) 1.51

Influence of residual myocardial ischaemia on induced ventricular arrhythmias following a first acute myocardial infarction. Eur Heart J (2001) 1.43

Mode of death in heart failure: findings from the ATLAS trial. Heart (2003) 1.24

Severity of left ventricular remodeling defines outcomes and response to therapy in heart failure: Valsartan heart failure trial (Val-HeFT) echocardiographic data. J Am Coll Cardiol (2004) 1.18

Protracted ventricular tachcardia induced by premature stimulation of the canine heart after coronary artery occlusion and reperfusion. Circ Res (1979) 1.16

Quantitative analysis of myocardial infarct structure in patients with ventricular tachycardia. Circulation (1986) 1.16

Influence of coronary bypass surgery on subsequent outcome of patients resuscitated from out of hospital cardiac arrest. J Am Coll Cardiol (1992) 1.06

Peri-infarct ischemia determined by cardiovascular magnetic resonance evaluation of myocardial viability and stress perfusion predicts future cardiovascular events in patients with severe ischemic cardiomyopathy. J Cardiovasc Magn Reson (2006) 0.95

Quantitative measurement of electrical instability as a function of myocardial infarct size in the dog. Am J Cardiol (1981) 0.90

Postinfarction sudden death: significance of inducible ventricular tachycardia and infarct size in a conscious canine model. Am Heart J (1985) 0.89

Effects of postmyocardial infarction scar size, cardiac function, and severity of coronary artery disease on QT interval dispersion as a risk factor for complex ventricular arrhythmia. Pacing Clin Electrophysiol (1998) 0.84

Effects of coronary artery bypass grafting on ventricular arrhythmias: results with electrophysiological testing and long-term follow-up. Pacing Clin Electrophysiol (1993) 0.82

Incremental prognostic value of left ventricular function by myocardial ECG-gated FDG PET imaging in patients with ischemic cardiomyopathy. J Nucl Cardiol (2004) 0.79

Infarct size and recurrence of ventricular arrhythmias after defibrillator implantation. Eur J Nucl Med (2000) 0.78

Articles by these authors

Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med (2007) 22.30

SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space. Magn Reson Med (2010) 4.33

Hyperpolarized C-13 spectroscopic imaging of the TRAMP mouse at 3T-initial experience. Magn Reson Med (2007) 4.13

Control over brain activation and pain learned by using real-time functional MRI. Proc Natl Acad Sci U S A (2005) 3.66

Double spin-echo sequence for rapid spectroscopic imaging of hyperpolarized 13C. J Magn Reson (2007) 3.35

FeCo/graphitic-shell nanocrystals as advanced magnetic-resonance-imaging and near-infrared agents. Nat Mater (2006) 3.34

Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations. J Cardiovasc Magn Reson (2009) 3.17

Saturated double-angle method for rapid B1+ mapping. Magn Reson Med (2006) 3.15

Rapid gridding reconstruction with a minimal oversampling ratio. IEEE Trans Med Imaging (2005) 3.11

Pre-conceptional vitamin/folic acid supplementation 2007: the use of folic acid in combination with a multivitamin supplement for the prevention of neural tube defects and other congenital anomalies. J Obstet Gynaecol Can (2007) 2.64

Informed Consent. N Engl J Med (2017) 2.56

Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles. Magn Reson Med (2005) 2.55

Effects of age, gender, obesity, and diabetes on the efficacy and safety of the selective A2A agonist regadenoson versus adenosine in myocardial perfusion imaging integrated ADVANCE-MPI trial results. JACC Cardiovasc Imaging (2008) 2.42

Metal-induced artifacts in MRI. AJR Am J Roentgenol (2011) 2.42

Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI. J Magn Reson (2008) 2.39

Expert consensus for multi-modality imaging evaluation of cardiovascular complications of radiotherapy in adults: a report from the European Association of Cardiovascular Imaging and the American Society of Echocardiography. Eur Heart J Cardiovasc Imaging (2013) 2.35

Design of flyback echo-planar readout gradients for magnetic resonance spectroscopic imaging. Magn Reson Med (2005) 2.33

Referenceless PRF shift thermometry. Magn Reson Med (2004) 2.31

Flexible real-time magnetic resonance imaging framework. Conf Proc IEEE Eng Med Biol Soc (2004) 2.11

Learned regulation of spatially localized brain activation using real-time fMRI. Neuroimage (2004) 2.08

ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA. Magn Reson Med (2014) 2.06

Improved pediatric MR imaging with compressed sensing. Radiology (2010) 1.98

SEMAC: Slice Encoding for Metal Artifact Correction in MRI. Magn Reson Med (2009) 1.98

3D compressed sensing for highly accelerated hyperpolarized (13)C MRSI with in vivo applications to transgenic mouse models of cancer. Magn Reson Med (2010) 1.92

Comparison of reporter gene and iron particle labeling for tracking fate of human embryonic stem cells and differentiated endothelial cells in living subjects. Stem Cells (2008) 1.90

Inhibition of microRNA-29b reduces murine abdominal aortic aneurysm development. J Clin Invest (2012) 1.84

Collagen matrices enhance survival of transplanted cardiomyoblasts and contribute to functional improvement of ischemic rat hearts. Circulation (2006) 1.75

MicroRNA-21 blocks abdominal aortic aneurysm development and nicotine-augmented expansion. Sci Transl Med (2012) 1.73

Nonlinear phase correction for navigated diffusion imaging. Magn Reson Med (2003) 1.70

Fast dynamic 3D MR spectroscopic imaging with compressed sensing and multiband excitation pulses for hyperpolarized 13C studies. Magn Reson Med (2010) 1.67

Investigation of tumor hyperpolarized [1-13C]-pyruvate dynamics using time-resolved multiband RF excitation echo-planar MRSI. Magn Reson Med (2010) 1.64

Pulse sequence for dynamic volumetric imaging of hyperpolarized metabolic products. J Magn Reson (2008) 1.64

Multiband excitation pulses for hyperpolarized 13C dynamic chemical-shift imaging. J Magn Reson (2008) 1.62

Ensuring safety of implanted devices under MRI using reversed RF polarization. Magn Reson Med (2010) 1.58

Coil compression for accelerated imaging with Cartesian sampling. Magn Reson Med (2012) 1.58

Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion. Magn Reson Med (2003) 1.57

FeCo/graphite nanocrystals for multi-modality imaging of experimental vascular inflammation. PLoS One (2011) 1.56

Analysis of multiple-acquisition SSFP. Magn Reson Med (2004) 1.54

Bound pool fractions complement diffusion measures to describe white matter micro and macrostructure. Neuroimage (2010) 1.54

Reduction of blurring in view angle tilting MRI. Magn Reson Med (2005) 1.53

Impaired coronary vasodilation by magnetic resonance angiography is associated with advanced coronary artery calcification. JACC Cardiovasc Imaging (2008) 1.51

Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging. Magn Reson Med (2007) 1.47

Colchicine poisoning: the dark side of an ancient drug. Clin Toxicol (Phila) (2010) 1.43

Multicontrast black-blood MRI of carotid arteries: comparison between 1.5 and 3 tesla magnetic field strengths. J Magn Reson Imaging (2006) 1.41

Expert consensus for multi-modality imaging evaluation of cardiovascular complications of radiotherapy in adults: a report from the European Association of Cardiovascular Imaging and the American Society of Echocardiography. J Am Soc Echocardiogr (2013) 1.31

Designing long-T2 suppression pulses for ultrashort echo time imaging. Magn Reson Med (2006) 1.31

Analysis of in situ and ex vivo vascular endothelial growth factor receptor expression during experimental aortic aneurysm progression. Arterioscler Thromb Vasc Biol (2009) 1.30

High-resolution FMRI at 1.5T using balanced SSFP. Magn Reson Med (2006) 1.30

Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organs. Med Phys (2010) 1.29

Real-time cardiac MRI at 3 tesla. Magn Reson Med (2004) 1.28

Human ferritin cages for imaging vascular macrophages. Biomaterials (2010) 1.28

Comparison of optical bioluminescence reporter gene and superparamagnetic iron oxide MR contrast agent as cell markers for noninvasive imaging of cardiac cell transplantation. Mol Imaging Biol (2008) 1.27

Full-brain coverage and high-resolution imaging capabilities of passband b-SSFP fMRI at 3T. Magn Reson Med (2008) 1.27

Dual in vivo magnetic resonance evaluation of magnetically labeled mouse embryonic stem cells and cardiac function at 1.5 t. Magn Reson Med (2006) 1.25

Functional brain imaging using a blood oxygenation sensitive steady state. Magn Reson Med (2003) 1.25

Complex data analysis in high-resolution SSFP fMRI. Magn Reson Med (2007) 1.23

Single breath-hold whole-heart MRA using variable-density spirals at 3T. Magn Reson Med (2006) 1.23

A human ferritin iron oxide nano-composite magnetic resonance contrast agent. Magn Reson Med (2008) 1.23

Folate fortification and supplementation--are we there yet? Reprod Toxicol (2008) 1.21

Steady-state diffusion-weighted imaging of in vivo knee cartilage. Magn Reson Med (2004) 1.19

Twenty-four Hours of Sleep, Sedentary Behavior, and Physical Activity with Nine Wearable Devices. Med Sci Sports Exerc (2016) 1.17

Sequence design for magnetic resonance spectroscopic imaging of prostate cancer at 3 T. Magn Reson Med (2005) 1.17

In vitro comparison of the biological effects of three transfection methods for magnetically labeling mouse embryonic stem cells with ferumoxides. Magn Reson Med (2007) 1.17

Fast pediatric 3D free-breathing abdominal dynamic contrast enhanced MRI with high spatiotemporal resolution. J Magn Reson Imaging (2013) 1.17

A fast method for designing time-optimal gradient waveforms for arbitrary k-space trajectories. IEEE Trans Med Imaging (2008) 1.16

Determinants of left ventricular mass in patients on hemodialysis: Frequent Hemodialysis Network (FHN) Trials. Circ Cardiovasc Imaging (2012) 1.16

Quantitative tissue characterization of infarct core and border zone in patients with ischemic cardiomyopathy by magnetic resonance is associated with future cardiovascular events. J Am Coll Cardiol (2010) 1.16

Magnetic resonance imaging of progressive cardiomyopathic changes in the db/db mouse. Am J Physiol Heart Circ Physiol (2006) 1.15

Improved slice selection for R2* mapping during cryoablation with eddy current compensation. J Magn Reson Imaging (2008) 1.15

Double knockdown of prolyl hydroxylase and factor-inhibiting hypoxia-inducible factor with nonviral minicircle gene therapy enhances stem cell mobilization and angiogenesis after myocardial infarction. Circulation (2011) 1.14

Comparison of new sequences for high-resolution cartilage imaging. Magn Reson Med (2003) 1.12

Accelerated slice encoding for metal artifact correction. J Magn Reson Imaging (2010) 1.12

Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion. Magn Reson Med (2013) 1.09

Images in clinical medicine. A swinging heart. N Engl J Med (2009) 1.09

Nonrigid motion correction in 3D using autofocusing with localized linear translations. Magn Reson Med (2012) 1.09

Protein cage nanoparticles bearing the LyP-1 peptide for enhanced imaging of macrophage-rich vascular lesions. ACS Nano (2011) 1.08

Minimum envelope roughness pulse design for reduced amplifier distortion in parallel excitation. Magn Reson Med (2010) 1.07

Multimodality evaluation of the viability of stem cells delivered into different zones of myocardial infarction. Circ Cardiovasc Imaging (2008) 1.06

Randomized trial of personal genomics for preventive cardiology: design and challenges. Circ Cardiovasc Genet (2012) 1.06

A molecular MRI probe to detect treatment of cardiac apoptosis in vivo. Magn Reson Med (2011) 1.05

Noninvasive assessment of coronary vasodilation using magnetic resonance angiography. J Am Coll Cardiol (2005) 1.05

Slice encoding for metal artifact correction with noise reduction. Magn Reson Med (2011) 1.04

Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction. J Magn Reson Imaging (2013) 1.04

Improved time series reconstruction for dynamic magnetic resonance imaging. IEEE Trans Med Imaging (2009) 1.04

High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence. Magn Reson Imaging (2006) 1.04

Spiral balanced steady-state free precession cardiac imaging. Magn Reson Med (2005) 1.03

Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition. Magn Reson Med (2012) 1.01

Time-optimal design for multidimensional and parallel transmit variable-rate selective excitation. Magn Reson Med (2009) 1.01

Manganese-guided cellular MRI of human embryonic stem cell and human bone marrow stromal cell viability. Magn Reson Med (2009) 1.00

Design of symmetric-sweep spectral-spatial RF pulses for spectral editing. Magn Reson Med (2004) 1.00

Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging. Magn Reson Med (2011) 0.99

Accelerating parameter mapping with a locally low rank constraint. Magn Reson Med (2014) 0.99

Effects of frequent hemodialysis on ventricular volumes and left ventricular remodeling. Clin J Am Soc Nephrol (2013) 0.98

High-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding. J Magn Reson Imaging (2007) 0.98