A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems.

PubWeight™: 1.97‹?› | Rank: Top 2%

🔗 View Article (PMC 2562256)

Published in Phys Med Biol on August 22, 2008

Authors

G K Yadava1, A T Kuhls-Gilcrist, S Rudin, V K Patel, K R Hoffmann, D R Bednarek

Author Affiliations

1: Toshiba Stroke Research Center, State University of New York at Buffalo, Buffalo, NY 14214, USA.

Articles citing this

The Solid-State X-Ray Image Intensifier (SSXII): An EMCCD-Based X-Ray Detector. Proc SPIE Int Soc Opt Eng (2008) 2.64

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager. Med Phys (2011) 1.85

Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements. Proc SPIE Int Soc Opt Eng (2009) 1.65

Improved contrast and spatial resolution with Single Photon Counting (SPC) for an area x-ray imager, the newly developed high-resolution Micro-Angiographic Fluoroscopic (MAF) detector. IEEE Nucl Sci Symp Conf Rec (1997) (2009) 1.10

Dose Reduction Technique Using a Combination of a Region of Interest (ROI) Material X-Ray Attenuator and Spatially Different Temporal Filtering for Fluoroscopic Interventions. Proc SPIE Int Soc Opt Eng (2012) 1.10

A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems. Med Phys (2010) 1.08

Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS). Proc SPIE Int Soc Opt Eng (2013) 0.98

Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics. Proc SPIE Int Soc Opt Eng (2010) 0.97

Noise variance analysis using a flat panel x-ray detector: a method for additive noise assessment with application to breast CT applications. Med Phys (2010) 0.95

Evaluating the performance of time-gated live-cell microscopy with lanthanide probes. Biophys J (2015) 0.80

Quantitative analysis of an enlarged area Solid State X-ray Image Intensifier (SSXII) detector based on Electron Multiplying Charge Coupled Device (EMCCD) technology. Proc SPIE Int Soc Opt Eng (2013) 0.80

Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF). Proc SPIE Int Soc Opt Eng (2012) 0.78

Quantification of breast lesion compositions using low-dose spectral mammography: A feasibility study. Med Phys (2016) 0.75

Characterization of energy response for photon-counting detectors using x-ray fluorescence. Med Phys (2014) 0.75

A CMOS-based high resolution fluoroscope (HRF) detector prototype with 49.5 μm pixels for use in endovascular image guided interventions (EIGI). Proc SPIE Int Soc Opt Eng (2017) 0.75

Articles cited by this

Micro-angiography for neuro-vascular imaging. I. Experimental evaluation and feasibility. Med Phys (2003) 3.06

Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: application to a new microangiographic system. Med Phys (2005) 2.87

Micro-angiography for neuro-vascular imaging. II. Cascade model analysis. Med Phys (2003) 2.28

Generalized Objective Performance Assessment of a New High-Sensitivity Microangiographic Fluoroscopic (HSMAF) Imaging System. Proc SPIE Int Soc Opt Eng (2008) 2.26

Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography). Med Phys (2000) 2.21

Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy. Med Phys (2004) 2.17

New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy. Proc SPIE Int Soc Opt Eng (2006) 2.01

Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications. Med Phys (2000) 1.98

Figures of merit for detectors in digital radiography. I. Flat background and deterministic blurring. Med Phys (2004) 1.68

Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector. Med Phys (2003) 1.67

CCD noise removal in digital images. IEEE Trans Image Process (2006) 1.63

X-ray detectors for digital radiography. Phys Med Biol (1997) 1.55

Generalized Performance Evaluation of X-ray Image Intensifier compared with a Microangiographic System. Proc SPIE Int Soc Opt Eng (2005) 1.41

The Rose model, revisited. J Opt Soc Am A Opt Image Sci Vis (1999) 1.34

A Prototype Micro-Angiographic Fluoroscope and Its Application in Animal Studies. Proc SPIE Int Soc Opt Eng (2005) 1.26

Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography. Med Phys (2007) 1.25

Toward consensus on quantitative assessment of medical imaging systems. Med Phys (1995) 1.24

Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector. Med Phys (1997) 1.01

Physical characterization of a prototype selenium-based full field digital mammography detector. Med Phys (2005) 0.97

On site evaluation of three flat panel detectors for digital radiography. Med Phys (2003) 0.92

Figures of merit for detectors in digital radiography. II. Finite number of secondaries and structured backgrounds. Med Phys (2004) 0.89

Investigation of basic imaging properties in digital radiography 10. Structure mottle of II-TV digital imaging systems. Med Phys (1987) 0.85

Receptor dose in digital fluorography: a comparison between theory and practice. Phys Med Biol (2001) 0.83

Quantum and noise limitations of the visual process. J Opt Soc Am (1953) 0.81

Articles by these authors

Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT). Proc SPIE Int Soc Opt Eng (2008) 3.49

Region of interest fluoroscopy. Med Phys (1992) 2.68

LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System. Proc SPIE Int Soc Opt Eng (2008) 2.06

Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents. Proc SPIE Int Soc Opt Eng (2004) 1.94

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager. Med Phys (2011) 1.85

Requirement for a beta 2-microglobulin-associated Fc receptor for acquisition of maternal IgG by fetal and neonatal mice. J Immunol (1995) 1.81

Region of interest (ROI) computed tomography (CT): Comparison with full field of view (FFOV) and truncated CT for a human head phantom. Proc SPIE Int Soc Opt Eng (2005) 1.63

Clinical application of region-of-interest techniques to radiologic imaging. Radiographics (1996) 1.39

Accurate characterization of image intensifier distortion. Med Phys (1992) 1.35

Rotational micro-CT using a clinical C-arm angiography gantry. Med Phys (2008) 1.34

Antibacterial Activity of Medicinal Plants Against Pathogens causing Complicated Urinary Tract Infections. Indian J Pharm Sci (2009) 1.31

Liver glucokinase: decreased activity in patients with type II diabetes. Horm Metab Res (1995) 1.30

Novel Multiplexer to Enable Multiple-Module Imaging with Adjustable High Spatial Resolution and Predetermined Display Bandwidth for Array Medical Imaging Systems. IEEE Nucl Sci Symp Conf Rec (1997) (2010) 1.27

Spatially different, real-time temporal filtering and dose reduction for dynamic image guidance during neurovascular interventions. Conf Proc IEEE Eng Med Biol Soc (2011) 1.22

Region of Interest (ROI) Computed Tomography. Proc SPIE Int Soc Opt Eng (2004) 1.19

Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging. Proc SPIE Int Soc Opt Eng (2008) 1.17

CT colonography with three-dimensional problem solving for detection of colonic polyps. AJR Am J Roentgenol (1998) 1.16

EMCCD-based high resolution dynamic x-ray detector for neurovascular interventions. Conf Proc IEEE Eng Med Biol Soc (2011) 1.14

Application of region-of-interest imaging techniques to neurointerventional radiology. Radiology (1996) 1.12

Filter material selection for region of interest radiologic imaging. Med Phys (1998) 1.11

Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions. Proc SPIE Int Soc Opt Eng (2009) 1.11

Dose Reduction Technique Using a Combination of a Region of Interest (ROI) Material X-Ray Attenuator and Spatially Different Temporal Filtering for Fluoroscopic Interventions. Proc SPIE Int Soc Opt Eng (2012) 1.10

Artifacts produced by moving grids. Radiology (1983) 1.08

Automatic filter placement device for region of interest (ROI) fluoroscopy. Health Phys (1997) 1.07

Self-calibration of a cone-beam micro-CT system. Med Phys (2009) 1.07

The Micro-Angiographic Fluoroscope (MAF) in High Definition (HD) Mode for Improved Contrast-to-Noise Ratio and Resolution in Fluoroscopy and Roadmapping. IEEE Nucl Sci Symp Conf Rec (1997) (2010) 1.06

Two dimensional extensible array configuration for EMCCD-based solid state x-ray detectors. Proc SPIE Int Soc Opt Eng (2012) 1.05

Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study. Proc SPIE Int Soc Opt Eng (2009) 1.05

Super-global distortion correction for a rotational C-arm x-ray image intensifier. Med Phys (1999) 1.03

On the ultrastructural diversity and essence of residual bodies in neuronal ceroid-lipofuscinosis. Mech Ageing Dev (1979) 1.02

Real-time equalization of region-of-interest fluoroscopic images using binary masks. Med Phys (1999) 1.01

Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology. Proc SPIE Int Soc Opt Eng (2008) 0.99

Graphics Processing Unit (GPU) implementation of image processing algorithms to improve system performance of the Control, Acquisition, Processing, and Image Display System (CAPIDS) of the Micro-Angiographic Fluoroscope (MAF). Proc SPIE Int Soc Opt Eng (2012) 0.98

Artifact reduction in truncated CT using Sinogram completion. Proc SPIE Int Soc Opt Eng (2005) 0.97

Computer-aided diagnosis of pulmonary nodules: results of a large-scale observer test. Radiology (1999) 0.96

Computer-aided diagnosis: development of automated schemes for quantitative analysis of radiographic images. Semin Ultrasound CT MR (1992) 0.95

Method for image equalization of ROI fluoroscopic images using mask localization, selection and subtraction. Comput Med Imaging Graph (1997) 0.95

Small simulated polyps in pig colon: sensitivity of CT virtual colography. Radiology (1997) 0.93

Development of a high quality film duplication system using a laser digitizer: comparison with computed radiography. Med Phys (1993) 0.92

Automatic bone segmentation technique for CT angiographic studies. J Comput Assist Tomogr (1999) 0.92

Evaluation of a second-generation self-expanding variable-porosity flow diverter in a rabbit elastase aneurysm model. AJNR Am J Neuroradiol (2011) 0.91

Implementation of digital multiplexing for high resolution X-ray detector arrays. Conf Proc IEEE Eng Med Biol Soc (2012) 0.89

An "intelligent" workstation for computer-aided diagnosis. Radiographics (1993) 0.89

Evaluation of imaging geometries calculated from biplane images. Med Phys (1998) 0.88

Real-time implementation of distortion corrections for a tiled EMCCD-based Solid State X-ray Image Intensifier (SSXII). Proc SPIE Int Soc Opt Eng (2009) 0.87

Clinical experience with an advanced laser digitizer for cost-effective digital radiography. Radiographics (1993) 0.87

Improved contrast in special procedures using a rotating aperture wheel (RAW) device. Radiology (1980) 0.85

Basic imaging properties of a large image intensifier-TV digital chest radiographic system. Invest Radiol (1987) 0.85

Method to rotate an endovascular device around the axis of a vessel using an external magnetic field. Med Phys (2007) 0.84

Automated calculation of the centerline of the human colon on CT images. Acad Radiol (1999) 0.84

An algorithm for mapping the catheter tip position on a fluorograph to the three-dimensional position in magnetic resonance angiography volume data. Phys Med Biol (2003) 0.83

Leukocyte docosahexaenoic acid in juvenile form of ceroid-lipofuscinosis. Neuropadiatrie (1978) 0.82

Digital radiography. A useful clinical tool for computer-aided diagnosis by quantitative analysis of radiographic images. Acta Radiol (1993) 0.81

Quantitative evaluation of vessel tracking techniques on coronary angiograms. Med Phys (1999) 0.81

Blurred-mask density compression for improved reproduction of radiographs. Invest Radiol (1991) 0.81

Implementation of region-of-interest fluoroscopy by using the road mapping mode of a real-time digital radiographic unit. Radiographics (1995) 0.80

Regulation of muscle pyruvate metabolism during exercise. Biochem Med Metab Biol (1986) 0.80

Oligosaccharyl diphosphodolichols in the ceroid-lipofuscinoses. Am J Med Genet Suppl (1988) 0.79

A novel approach to flow quantification in brain arteriovenous malformations prior to enbucrilate embolization: use of insoluble contrast (Ethiodol droplet) angiography. J Neurosurg (1998) 0.79

In vitro study of antimicrobial activity of adhatoda vasika Linn. (leaf extract) on gingival inflammation--a preliminary report. Indian J Med Sci (1984) 0.78

High Resolution Emission and Transmission Imaging Using the Same Detector. IEEE Nucl Sci Symp Conf Rec (1997) (2010) 0.78

Modulation of pristane-induced arthritis by mycobacterial antigens. Autoimmunity (1991) 0.78

Dose reduction by moving a region of interest (ROI) beam attenuator to follow a moving object of interest. Proc SPIE Int Soc Opt Eng (2012) 0.78

Central actions of some beta-adrenoceptor blocking agents. Arzneimittelforschung (1974) 0.78

Dose reduction during fluoroscopic placement of feeding tubes. Radiology (1991) 0.78