Flat-panel volume CT: fundamental principles, technology, and applications.

PubWeight™: 1.15‹?› | Rank: Top 10%

🔗 View Article (PMID 19001655)

Published in Radiographics on November 12, 2008

Authors

Rajiv Gupta1, Arnold C Cheung, Soenke H Bartling, Jennifer Lisauskas, Michael Grasruck, Christianne Leidecker, Bernhard Schmidt, Thomas Flohr, Thomas J Brady

Author Affiliations

1: Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA. rgupta1@partners.org

Articles citing this

Bone density, geometry, microstructure, and stiffness: Relationships between peripheral and central skeletal sites assessed by DXA, HR-pQCT, and cQCT in premenopausal women. J Bone Miner Res (2010) 1.50

Combined fluoroscopy- and CT-guided transthoracic needle biopsy using a C-arm cone-beam CT system: comparison with fluoroscopy-guided biopsy. Korean J Radiol (2011) 1.21

Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol (2012) 1.09

Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol (2010) 1.01

Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT. Skeletal Radiol (2010) 0.94

Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety. Br J Radiol (2011) 0.93

Bone fragility and imaging techniques. Clin Cases Miner Bone Metab (2009) 0.90

Accuracy and speed of robotic assisted needle interventions using a modern cone beam computed tomography intervention suite: a phantom study. Eur Radiol (2012) 0.88

Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects. Skeletal Radiol (2015) 0.88

Dentomaxillofacial imaging with panoramic views and cone beam CT. Insights Imaging (2015) 0.85

The value of flat-detector computed tomography during catheterisation of congenital heart disease. Eur Radiol (2011) 0.85

Skull base CT: normative values for size and symmetry of the facial nerve canal, foramen ovale, pterygoid canal, and foramen rotundum. Surg Radiol Anat (2012) 0.84

Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system. J Med Imaging (Bellingham) (2016) 0.83

Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules. Eur Radiol (2015) 0.80

Device setting modifications for 3D flatpanel imaging in skull base surgery. Eur Arch Otorhinolaryngol (2012) 0.80

High-resolution CT vascular imaging using blood pool contrast agents. Methodist Debakey Cardiovasc J (2012) 0.80

Association between bone indices assessed by DXA, HR-pQCT and QCT scans in post-menopausal women. J Bone Miner Metab (2015) 0.80

Toward the era of a one-stop imaging service using an angiography suite for neurovascular disorders. Biomed Res Int (2013) 0.79

Three-Dimensional Rotational Angiography in the Pediatric Cath Lab: Optimizing Aortic Interventions. Pediatr Cardiol (2015) 0.78

A comparative study of the diagnostic accuracy of cone beam computed tomography and intraoral radiographic modalities for the detection of noncavitated caries. Clin Oral Investig (2014) 0.78

C-arm CT for histomorphometric evaluation of lumbar spine trabecular microarchitecture: a study on anorexia nervosa patients. Br J Radiol (2013) 0.77

Percutaneous Transthoracic Lung Biopsy: Comparison Between C-Arm Cone-Beam CT and Conventional CT Guidance. Transl Oncol (2015) 0.77

Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws. Skeletal Radiol (2014) 0.77

What are the basic concepts of temporal, contrast, and spatial resolution in cardiac CT? J Cardiovasc Comput Tomogr (2009) 0.76

Cone beam CT evaluation of the presence of anatomic accessory canals in the jaws. Dentomaxillofac Radiol (2014) 0.75

Image-guided thoracoscopic surgery with dye localization in a hybrid operating room. J Thorac Dis (2016) 0.75

Accuracy of Intraoperative Computed Tomography during Deep Brain Stimulation Procedures: Comparison with Postoperative Magnetic Resonance Imaging. Stereotact Funct Neurosurg (2017) 0.75

Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation. Eur Radiol (2017) 0.75

Articles by these authors

First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol (2005) 5.21

Material differentiation by dual energy CT: initial experience. Eur Radiol (2006) 4.96

Coronary computed tomography angiography for early triage of patients with acute chest pain: the ROMICAT (Rule Out Myocardial Infarction using Computer Assisted Tomography) trial. J Am Coll Cardiol (2009) 4.54

In vivo 18F-fluorodeoxyglucose positron emission tomography imaging provides a noninvasive measure of carotid plaque inflammation in patients. J Am Coll Cardiol (2006) 3.91

Diagnostic and prognostic value of absence of coronary artery calcification. JACC Cardiovasc Imaging (2009) 3.23

Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound. Circulation (2003) 3.09

Multiple sulfatase deficiency is caused by mutations in the gene encoding the human C(alpha)-formylglycine generating enzyme. Cell (2003) 2.93

Techniques and applications of automatic tube current modulation for CT. Radiology (2004) 2.83

Coronary multidetector computed tomography in the assessment of patients with acute chest pain. Circulation (2006) 2.82

Cardiac magnetic resonance with T2-weighted imaging improves detection of patients with acute coronary syndrome in the emergency department. Circulation (2008) 2.74

Evolution of coronary computed tomography radiation dose reduction at a tertiary referral center. Am J Med (2012) 2.68

Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol (2002) 2.65

Noninvasive in vivo measurement of vascular inflammation with F-18 fluorodeoxyglucose positron emission tomography. J Nucl Cardiol (2005) 2.65

Adenosine-induced stress myocardial perfusion imaging using dual-source cardiac computed tomography. J Am Coll Cardiol (2009) 2.64

Clinical significance of minimal residual disease quantification in adult patients with standard-risk acute lymphoblastic leukemia. Blood (2005) 2.58

Feasibility of FDG imaging of the coronary arteries: comparison between acute coronary syndrome and stable angina. JACC Cardiovasc Imaging (2010) 2.38

Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol (2006) 2.36

Molecular allelokaryotyping of pediatric acute lymphoblastic leukemias by high-resolution single nucleotide polymorphism oligonucleotide genomic microarray. Blood (2007) 2.31

Prognostic value of CT angiography for major adverse cardiac events in patients with acute chest pain from the emergency department: 2-year outcomes of the ROMICAT trial. JACC Cardiovasc Imaging (2011) 2.15

Activating NOTCH1 mutations predict favorable early treatment response and long-term outcome in childhood precursor T-cell lymphoblastic leukemia. Blood (2006) 2.10

Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation (2004) 2.06

Comparison of postprocessing techniques for the detection of perfusion defects by cardiac computed tomography in patients presenting with acute ST-segment elevation myocardial infarction. J Cardiovasc Comput Tomogr (2010) 2.04

Optimization of ex vivo CT- and MR- imaging of atherosclerotic vessel wall changes. Int J Cardiovasc Imaging (2004) 2.04

Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort--consequences for progression studies. Eur J Radiol (2006) 1.99

Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience. Eur J Radiol (2006) 1.99

Analytic approaches to establish the diagnostic accuracy of coronary computed tomography angiography as a tool for clinical decision making. Am J Cardiol (2007) 1.95

Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology (2004) 1.94

Advances in cardiac imaging with 16-section CT systems. Acad Radiol (2003) 1.93

Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography. Radiology (2010) 1.90

Low-dose CT of the lung: potential value of iterative reconstructions. Eur Radiol (2012) 1.85

Diagnostic performance of stress perfusion and delayed-enhancement MR imaging in patients with coronary artery disease. Radiology (2006) 1.85

Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomography. J Comput Assist Tomogr (2012) 1.82

Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol (2009) 1.77

High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr (2009) 1.75

Thiopurine methyltransferase (TPMT) genotype and early treatment response to mercaptopurine in childhood acute lymphoblastic leukemia. JAMA (2005) 1.74

Molecular basis for multiple sulfatase deficiency and mechanism for formylglycine generation of the human formylglycine-generating enzyme. Cell (2005) 1.71

Quantification of left ventricular noncompaction and trabecular delayed hyperenhancement with cardiac MRI: correlation with clinical severity. AJR Am J Roentgenol (2007) 1.70

Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. Eur Radiol (2011) 1.69

Eligibility for renal denervation: experience at 11 European expert centers. Hypertension (2014) 1.68

Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. AJR Am J Roentgenol (2006) 1.65

Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol (2011) 1.63

Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology (2009) 1.63

Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients. Eur Radiol (2010) 1.56

Assessment of nonstenotic coronary lesions by 64-slice multidetector computed tomography in comparison to intravascular ultrasound: evaluation of nonculprit coronary lesions. J Cardiovasc Comput Tomogr (2008) 1.55

Assessment of the presence and extent of coronary collateralization by coronary computed tomographic angiography in patients with total occlusions. Int J Cardiovasc Imaging (2008) 1.53

Normalized metal artifact reduction (NMAR) in computed tomography. Med Phys (2010) 1.52

Weighted FBP--a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch. Phys Med Biol (2004) 1.52

Dose performance of a 64-channel dual-source CT scanner. Radiology (2007) 1.51

Feasibility of discriminating uric acid from non-uric acid renal stones using consecutive spatially registered low- and high-energy scans obtained on a conventional CT scanner. AJR Am J Roentgenol (2015) 1.51

Results of a prospective protocol of computed tomographic angiography in place of catheter angiography as the only diagnostic and pretreatment planning study for cerebral aneurysms by a combined neurovascular team. Neurosurgery (2004) 1.50

Reperfused myocardial infarction: contrast-enhanced 64-Section CT in comparison to MR imaging. Radiology (2008) 1.49

Evaluating global and regional left ventricular function in patients with reperfused acute myocardial infarction by 64-slice multidetector CT: a comparison to magnetic resonance imaging. J Cardiovasc Comput Tomogr (2009) 1.46

A general binding mechanism for all human sulfatases by the formylglycine-generating enzyme. Proc Natl Acad Sci U S A (2005) 1.45

Quantification of nonculprit coronary lesions: comparison of cardiac 64-MDCT and invasive coronary angiography. AJR Am J Roentgenol (2008) 1.45

Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization. Eur Radiol (2006) 1.44

Coronary stent assessability by 64 slice multi-detector computed tomography. Catheter Cardiovasc Interv (2007) 1.42

Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS. Atherosclerosis (2006) 1.41

Distinct gene expression profiles determine molecular treatment response in childhood acute lymphoblastic leukemia. Blood (2004) 1.39

Wavelet based noise reduction in CT-images using correlation analysis. IEEE Trans Med Imaging (2008) 1.38

Comprehensive assessment of myocardial perfusion defects, regional wall motion, and left ventricular function by using 64-section multidetector CT. Radiology (2008) 1.37

Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients. Eur Radiol (2010) 1.35

Molecular characterization of the human Calpha-formylglycine-generating enzyme. J Biol Chem (2005) 1.35

Cloning of genes involved in chromosomal translocations by high-resolution single nucleotide polymorphism genomic microarray. Proc Natl Acad Sci U S A (2008) 1.34

Distribution of inflammation within carotid atherosclerotic plaques with high-risk morphological features: a comparison between positron emission tomography activity, plaque morphology, and histopathology. Circ Cardiovasc Imaging (2011) 1.33

Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience. Int J Cardiovasc Imaging (2010) 1.33

Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest Radiol (2006) 1.32

Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness. Invest Radiol (2011) 1.30

Frequency split metal artifact reduction (FSMAR) in computed tomography. Med Phys (2012) 1.27

Characterization of urinary stones with dual-energy CT: improved differentiation using a tin filter. Invest Radiol (2010) 1.27

Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography. Invest Radiol (2011) 1.27

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality. Med Phys (2009) 1.25

Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound. Am J Cardiol (2004) 1.23

Relationship of the esophagus and aorta to the left atrium and pulmonary veins: implications for catheter ablation of atrial fibrillation. Heart Rhythm (2005) 1.23

Association between cardiovascular risk profiles and the presence and extent of different types of coronary atherosclerotic plaque as detected by multidetector computed tomography. Arterioscler Thromb Vasc Biol (2008) 1.22

Molecular basis of multiple sulfatase deficiency, mucolipidosis II/III and Niemann-Pick C1 disease - Lysosomal storage disorders caused by defects of non-lysosomal proteins. Biochim Biophys Acta (2008) 1.21

Crystal structure of human pFGE, the paralog of the Calpha-formylglycine-generating enzyme. J Biol Chem (2005) 1.21

Stimulation of endothelial nitric oxide synthase by proinsulin C-peptide. Nitric Oxide (2003) 1.20

The human SUMF1 gene, required for posttranslational sulfatase modification, defines a new gene family which is conserved from pro- to eukaryotes. Gene (2003) 1.20

Dual-source dual-energy CT with additional tin filtration: Dose and image quality evaluation in phantoms and in vivo. AJR Am J Roentgenol (2010) 1.20

Cardiac spiral dual-source CT with high pitch: a feasibility study. Eur Radiol (2009) 1.20

Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteries. Eur J Radiol (2006) 1.20

Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography. Invest Radiol (2009) 1.19

Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients. Acad Radiol (2008) 1.19

Retrospective motion gating in small animal CT of mice and rats. Invest Radiol (2007) 1.18

Closing in on the K edge: coronary CT angiography at 100, 80, and 70 kV-initial comparison of a second- versus a third-generation dual-source CT system. Radiology (2014) 1.18

Locating the anomalous scatterer substructures in halide and sulfur phasing. Acta Crystallogr D Biol Crystallogr (2002) 1.17

Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology (2011) 1.16

Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping. Invest Radiol (2014) 1.15