Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE).

PubWeight™: 1.22‹?› | Rank: Top 10%

🔗 View Article (PMC 2731673)

Published in Magn Reson Med on May 01, 2009

Authors

J F Magland1, M J Wald, F W Wehrli

Author Affiliations

1: Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania 19104, USA. Jeremy.Magland@gmail.com

Articles citing this

Structural and mechanical parameters of trabecular bone estimated from in vivo high-resolution magnetic resonance images at 3 tesla field strength. J Magn Reson Imaging (2010) 1.14

Micro-MR imaging-based computational biomechanics demonstrates reduction in cortical and trabecular bone strength after renal transplantation. Radiology (2012) 1.05

Computational biomechanics of the distal tibia from high-resolution MR and micro-CT images. Bone (2010) 1.04

Pulse sequence programming in a dynamic visual environment: SequenceTree. Magn Reson Med (2015) 1.03

3D fast spin echo with out-of-slab cancellation: a technique for high-resolution structural imaging of trabecular bone at 7 Tesla. Magn Reson Med (2010) 1.02

Accuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone. J Bone Miner Res (2010) 0.99

Performance of the MRI-based virtual bone biopsy in the distal radius: serial reproducibility and reliability of structural and mechanical parameters in women representative of osteoporosis study populations. Bone (2011) 0.94

Performance of μMRI-Based virtual bone biopsy for structural and mechanical analysis at the distal tibia at 7T field strength. J Magn Reson Imaging (2011) 0.90

In vivo high-resolution magnetic resonance skin imaging at 1.5 T and 3 T. Magn Reson Med (2010) 0.89

Evaluation of trabecular microarchitecture in nonosteoporotic postmenopausal women with and without fracture. J Bone Miner Res (2012) 0.83

Helmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T. J Magn Reson (2011) 0.82

Long lived NMR signal in bone. J Magn Reson (2013) 0.81

Potential of in vivo MRI-based nonlinear finite-element analysis for the assessment of trabecular bone post-yield properties. Med Phys (2013) 0.80

On the significance of motion degradation in high-resolution 3D μMRI of trabecular bone. Acad Radiol (2011) 0.80

Effects of testosterone and growth hormone on the structural and mechanical properties of bone by micro-MRI in the distal tibia of men with hypopituitarism. J Clin Endocrinol Metab (2014) 0.79

Real-time motion correction for high-resolution larynx imaging. Magn Reson Med (2011) 0.79

Non-destructive characterization of microdamage in cortical bone using low field pulsed NMR. J Mech Behav Biomed Mater (2010) 0.79

Assessment of trabecular bone yield and post-yield behavior from high-resolution MRI-based nonlinear finite element analysis at the distal radius of premenopausal and postmenopausal women susceptible to osteoporosis. Acad Radiol (2013) 0.76

Registration-based autofocusing technique for automatic correction of motion artifacts in time-series studies of high-resolution bone MRI. J Magn Reson Imaging (2014) 0.75

Articles cited by this

Bone quality--the material and structural basis of bone strength and fragility. N Engl J Med (2006) 7.45

Measurement of signal intensities in the presence of noise in MR images. Med Phys (1985) 7.43

Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med (1997) 4.56

Principles and applications of balanced SSFP techniques. Eur Radiol (2003) 3.26

Musculoskeletal MRI at 3.0 T: relaxation times and image contrast. AJR Am J Roentgenol (2004) 2.94

Prevention of postmenopausal bone loss by a low-magnitude, high-frequency mechanical stimuli: a clinical trial assessing compliance, efficacy, and safety. J Bone Miner Res (2003) 2.72

Structural and functional assessment of trabecular and cortical bone by micro magnetic resonance imaging. J Magn Reson Imaging (2007) 2.24

Improved data reconstruction method for GRAPPA. Magn Reson Med (2005) 1.69

Magnetic resonance imaging of trabecular bone structure. Top Magn Reson Imaging (2002) 1.46

Why fat is bright in RARE and fast spin-echo imaging. J Magn Reson Imaging (1992) 1.46

Fast 3D large-angle spin-echo imaging (3D FLASE). Magn Reson Med (1996) 1.29

Advanced imaging assessment of bone quality. Ann N Y Acad Sci (2006) 1.26

Image metric-based correction (autofocusing) of motion artifacts in high-resolution trabecular bone imaging. J Magn Reson Imaging (2007) 1.26

In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis. Magn Reson Med (1999) 1.21

Trabecular bone structure analysis in the limited spatial resolution regime of in vivo MRI. Acad Radiol (2008) 1.19

Composition of MRI phantom equivalent to human tissues. Med Phys (2005) 1.07

Application of refocused steady-state free-precession methods at 1.5 and 3 T to in vivo high-resolution MRI of trabecular bone: simulations and experiments. J Magn Reson Imaging (2005) 1.01

Implications of pulse sequence in structural imaging of trabecular bone. J Magn Reson Imaging (2005) 1.00

Fully balanced steady-state 3D-spin-echo (bSSSE) imaging at 3 Tesla. Magn Reson Med (2006) 0.97

Nuclear magnetic resonance methods for determining chemical-exchange rates. J Am Chem Soc (1966) 0.92

Fast low-angle dual spin-echo (FLADE): a new robust pulse sequence for structural imaging of trabecular bone. Magn Reson Med (2006) 0.88

Coherence-induced artifacts in large-flip-angle steady-state spin-echo imaging. Magn Reson Med (2004) 0.87

Articles by these authors

Water magnetic relaxation dispersion in biological systems: the contribution of proton exchange and implications for the noninvasive detection of cartilage degradation. Proc Natl Acad Sci U S A (2001) 2.07

Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone. Magn Reson Med (1997) 1.44

Method for image-based measurement of the reversible and irreversible contribution to the transverse-relaxation rate. J Magn Reson B (1996) 1.34

Reproducibility and error sources of micro-MRI-based trabecular bone structural parameters of the distal radius and tibia. Bone (2004) 1.32

Fast 3D large-angle spin-echo imaging (3D FLASE). Magn Reson Med (1996) 1.29

Measurement of phosphorus content in normal and osteomalacic rabbit bone by solid-state 3D radial imaging. Magn Reson Med (2006) 1.22

In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis. Magn Reson Med (1999) 1.21

A noncontact, nondestructive method for quantifying intratissue deformations and strains. J Biomech Eng (2002) 1.21

Topological analysis of trabecular bone MR images. IEEE Trans Med Imaging (2000) 1.20

Ultra-short echo-time MRI detects changes in bone mineralization and water content in OVX rat bone in response to alendronate treatment. Bone (2010) 1.16

In vivo MR micro imaging with conventional radiofrequency coils cooled to 77 degrees K. Magn Reson Med (2000) 1.14

Mechanisms of contrast in NMR imaging. J Comput Assist Tomogr (1984) 1.13

Postprocessing technique to correct for background gradients in image-based R*(2) measurements. Magn Reson Med (2000) 1.10

In vivo quantitative characterization of trabecular bone by NMR interferometry and localized proton spectroscopy. Magn Reson Med (1991) 1.06

High-speed spectroscopic imaging for cancellous bone marrow R(2)* mapping and lipid quantification. Magn Reson Imaging (2000) 1.06

Methodology for the measurement and analysis of relaxation times in proton imaging. Magn Reson Imaging (1987) 1.06

Multi-modality study of the compositional and mechanical implications of hypomineralization in a rabbit model of osteomalacia. Bone (2007) 1.05

In vivo MR microscopy of the human skin. Magn Reson Med (1997) 1.01

Structural MRI of carotid artery atherosclerotic lesion burden and characterization of hemispheric cerebral blood flow before and after carotid endarterectomy. NMR Biomed (2006) 0.94

The dependence of nuclear magnetic resonance (NMR) image contrast on intrinsic and pulse sequence timing parameters. Magn Reson Imaging (1984) 0.94

A single-scan imaging technique for measurement of the relative concentrations of fat and water protons and their transverse relaxation times. J Magn Reson (1997) 0.93

Relationship between NMR transverse relaxation, trabecular bone architecture, and strength. Proc Natl Acad Sci U S A (1993) 0.93

Multipoint mapping for imaging of semi-solid materials. J Magn Reson (2003) 0.92

Chemical shift-induced amplitude modulations in images obtained with gradient refocusing. Magn Reson Imaging (1987) 0.92

Malignant uveal melanoma and simulating lesions: MR imaging evaluation. Radiology (1986) 0.90

Determination of background gradients with diffusion MR imaging. J Magn Reson Imaging (1995) 0.89

Variable TE gradient and spin echo sequences for in vivo MR microscopy of short T2 species. Magn Reson Med (1998) 0.89

Effect of intersection spacing on MR image contrast and study time. Radiology (1986) 0.88

Fast low-angle dual spin-echo (FLADE): a new robust pulse sequence for structural imaging of trabecular bone. Magn Reson Med (2006) 0.88

Magnetic field distribution in models of trabecular bone. Magn Reson Med (1993) 0.87

Probability-based structural parameters from three-dimensional nuclear magnetic resonance images as predictors of trabecular bone strength. Med Phys (1997) 0.85

Three-dimensional nuclear magnetic resonance microimaging of trabecular bone. J Bone Miner Res (1995) 0.85

On the fractal nature of trabecular structure. Med Phys (1994) 0.84

High-resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo. Magn Reson Med (1993) 0.84

Mapping of the magnetic-field distribution in cancellous bone. J Magn Reson B (1996) 0.83

Field strength and angle dependence of trabecular bone marrow transverse relaxation in the calcaneus. J Magn Reson Imaging (1997) 0.82

Reproducibility of relaxation and spin-density parameters in phantoms and the human brain measured by MR imaging at 1.5 T. Magn Reson Med (1986) 0.82

Construction and calibration of a 50 T/m z-gradient coil for quantitative diffusion microimaging. J Magn Reson (2007) 0.82

Magnetic susceptibility artifacts in gradient-recalled echo MR imaging. AJNR Am J Neuroradiol (1989) 0.81

General algorithm for automated off-center MRI. Magn Reson Med (2006) 0.80

SAR reduced pulse sequences. Magn Reson Imaging (1988) 0.80

Cerebral magnetic resonance: comparison of high and low field strength imaging. Radiology (1984) 0.79

Experimental evaluation of a surface charge method for computing the induced magnetic field in trabecular bone. J Magn Reson (1999) 0.79

Time-of-flight MR flow imaging: selective saturation recovery with gradient refocusing. Radiology (1986) 0.79

Quantification of contrast in clinical MR brain imaging at high magnetic field. Invest Radiol (1985) 0.78

Quantitative analysis of trabecular microstructure by 400 MHz nuclear magnetic resonance imaging. J Bone Miner Res (1995) 0.78

Effect of prostaglandin and bisphosphonate on cancellous bone volume and structure in the ovariectomized rat studied by quantitative three-dimensional nuclear magnetic resonance microscopy. J Bone Miner Res (1999) 0.78

MR imaging of venous and arterial flow by a selective saturation-recovery spin echo (SSRSE) method. J Comput Assist Tomogr (1985) 0.78

Trabecular bone volume fraction mapping by low-resolution MRI. Magn Reson Med (2001) 0.78

High-field surface-coil MR imaging of localized anatomy. AJNR Am J Neuroradiol (1985) 0.77

Magnetic resonance imaging of pituitary lesions using 1.0 to 1.5 T field strength. Radiology (1984) 0.76

Pseudoatrophy of the cervical portion of the spinal cord on MR images: a manifestation of the truncation artifact? AJNR Am J Neuroradiol (1990) 0.76

Three-dimensional digital topolgical analysis of trabecular bone. Adv Exp Med Biol (2001) 0.76

Vertebral deformities and fractures are associated with MRI and pQCT measures obtained at the distal tibia and radius of postmenopausal women. Osteoporos Int (2013) 0.76

MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections. Radiology (1987) 0.76

Spatial misregistration of vascular flow during MR imaging of the CNS: cause and clinical significance. AJR Am J Roentgenol (1990) 0.75

A Bayesian approach to subvoxel tissue classification in NMR microscopic images of trabecular bone. Magn Reson Med (1994) 0.75

Localization methods for nuclear magnetic resonance spectroscopy in vivo. Circulation (1985) 0.75

Popliteal artery hemodynamics: MR imaging-US correlation. Radiology (1991) 0.75

Pseudoatrophy of the cervical portion of the spinal cord on MR images: a manifestation of the truncation artifact? AJR Am J Roentgenol (1990) 0.75

Spatial misregistration of vascular flow during MR imaging of the CNS: cause and clinical significance. AJNR Am J Neuroradiol (1990) 0.75

A mathematical model for signal from spins flowing during the application of spin echo pulse sequences. Magn Reson Imaging (1988) 0.75

Orbital imaging: factors determining magnetic resonance imaging appearance. Radiol Clin North Am (1987) 0.75

Cervical spine MR imaging using multislice gradient echo imaging: comparison with cardiac gated spin echo. Magn Reson Imaging (1989) 0.75

Predictability of SNR and reader preference in clinical MR imaging. Magn Reson Imaging (1990) 0.75

Relationship between cancellous bone induced magnetic field and ultrastructure in a rat ovariectomy model. Magn Reson Imaging (2000) 0.75

Differential diagnosis of hepatic neoplasms: spin echo versus gadolinium-diethylenetriaminepentaacetate-enhanced gradient echo imaging. Magn Reson Q (1991) 0.75