Published in Jpn J Ophthalmol on December 30, 2010
Optic nerve head and fibre layer imaging for diagnosing glaucoma. Cochrane Database Syst Rev (2015) 1.05
Comparison of two different spectral domain optical coherence tomography devices in the detection of localized retinal nerve fiber layer defects. Jpn J Ophthalmol (2013) 0.83
Width of abnormal ganglion cell complex area determined using optical coherence tomography to predict glaucoma. Jpn J Ophthalmol (2013) 0.81
Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma. Med Sci Monit (2012) 0.79
Glaucoma diagnosis optic disc analysis comparing Cirrus spectral domain optical coherence tomography and Heidelberg retina tomograph II. Jpn J Ophthalmol (2012) 0.76
The glaucoma detection capability of spectral-domain OCT and GDx-VCC deviation maps in early glaucoma patients with localized visual field defects. Graefes Arch Clin Exp Ophthalmol (2013) 0.75
Scanning laser polarimetry in glaucoma. Indian J Ophthalmol (2014) 0.75
Effects of ocular rotation on parapapillary retinal nerve fiber layer thickness analysis measured with spectral-domain optical coherence tomography. Jpn J Ophthalmol (2012) 0.75
Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics (1988) 70.41
Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol (1991) 7.61
Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology (1996) 7.00
Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT. Invest Ophthalmol Vis Sci (2004) 4.81
Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. Arch Ophthalmol (2004) 4.01
Optical coherence tomography to detect and manage retinal disease and glaucoma. Am J Ophthalmol (2004) 3.79
Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography. Ophthalmology (2000) 3.34
Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes. Invest Ophthalmol Vis Sci (2005) 3.02
Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study. Ophthalmology (2009) 2.96
Progression of disc and field damage in early glaucoma. Arch Ophthalmol (1993) 2.30
Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness. Br J Ophthalmol (2009) 2.12
Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation. Am J Ophthalmol (2005) 1.44
Diagnostic accuracy of the GDx VCC for glaucoma. Ophthalmology (2004) 1.43
Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage. Graefes Arch Clin Exp Ophthalmol (2005) 1.42
Correlation between local glaucomatous visual field defects and loss of nerve fiber layer thickness measured with polarimetry and spectral domain OCT. Invest Ophthalmol Vis Sci (2009) 1.41
Comparison of spectral- and time-domain optical coherence tomography for retinal thickness measurements in healthy and diseased eyes. Am J Ophthalmol (2009) 1.39
Longitudinal variability of optic disc and retinal nerve fiber layer measurements. Invest Ophthalmol Vis Sci (2008) 1.38
Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma. Acta Ophthalmol Scand (2006) 1.34
Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography. Arch Ophthalmol (2009) 1.31
Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes. Am J Ophthalmol (2003) 1.17
Long-term variability of GDx VCC retinal nerve fiber layer thickness measurements. J Glaucoma (2007) 0.93
Scanning laser polarimetry - a review. Clin Experiment Ophthalmol (2008) 0.86
Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects. Eur J Ophthalmol (2005) 0.85
Scanning laser polarimetry with variable corneal compensation and detection of glaucomatous optic neuropathy. Graefes Arch Clin Exp Ophthalmol (2005) 0.84
Longitudinal measurement variability of corneal birefringence and retinal nerve fiber layer thickness in scanning laser polarimetry with variable corneal compensation. Arch Ophthalmol (2008) 0.79
Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes. Ophthalmologica (2006) 0.78
The relationship between optical coherence tomography and scanning laser polarimetry measurements in glaucoma. Korean J Ophthalmol (2006) 0.76
Relationship between GDx VCC and Stratus OCT in juvenile glaucoma. Eye (Lond) (2009) 0.76
Comparison of retinal nerve fiber layer thickness measured by Cirrus HD and Stratus optical coherence tomography. Ophthalmology (2009) 2.30
Macular and peripapillary retinal nerve fiber layer measurements by spectral domain optical coherence tomography in normal-tension glaucoma. Invest Ophthalmol Vis Sci (2009) 2.12
Effect of combined cataract surgery and ranibizumab injection in postoperative macular edema in nonproliferative diabetic retinopathy. Retina (2014) 2.05
Relationship between visual field sensitivity and macular ganglion cell complex thickness as measured by spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci (2010) 1.57
Detection of macular ganglion cell loss in preperimetric glaucoma patients with localized retinal nerve fibre defects by spectral-domain optical coherence tomography. Clin Experiment Ophthalmol (2013) 1.55
Circadian fluctuation of mean ocular perfusion pressure is a consistent risk factor for normal-tension glaucoma. Invest Ophthalmol Vis Sci (2007) 1.36
Twenty-four hour ocular perfusion pressure fluctuation and risk of normal-tension glaucoma progression. Invest Ophthalmol Vis Sci (2009) 1.34
Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br J Ophthalmol (2010) 1.32
Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography. Arch Ophthalmol (2009) 1.31
Effect of nocturnal blood pressure reduction on circadian fluctuation of mean ocular perfusion pressure: a risk factor for normal tension glaucoma. Invest Ophthalmol Vis Sci (2006) 1.14
Detection of glaucomatous progression by spectral-domain optical coherence tomography. Ophthalmology (2013) 1.13
Detection of glaucoma progression by assessment of segmented macular thickness data obtained using spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci (2012) 1.12
Apoptosis in keratocytes caused by mitomycin C. Invest Ophthalmol Vis Sci (2003) 1.08
Longitudinal changes in anterior segment parameters after laser peripheral iridotomy assessed by anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci (2013) 1.08
Imaging of the retinal nerve fibre layer with spectral domain optical coherence tomography for glaucoma diagnosis. Br J Ophthalmol (2010) 1.05
Comparison of optic disc margin identified by color disc photography and high-speed ultrahigh-resolution optical coherence tomography. Arch Ophthalmol (2008) 1.04
Evaluation of lamina cribrosa in pseudoexfoliation syndrome using spectral-domain optical coherence tomography enhanced depth imaging. Ophthalmology (2013) 1.03
Asymmetry in hemifield macular thickness as an early indicator of glaucomatous change. Invest Ophthalmol Vis Sci (2012) 1.02
Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography. Acta Ophthalmol (2009) 1.02
Characteristics of visual field progression in medically treated normal-tension glaucoma patients with unstable ocular perfusion pressure. Invest Ophthalmol Vis Sci (2011) 1.02
Level of vascular endothelial growth factor in aqueous humor and surgical results of ahmed glaucoma valve implantation in patients with neovascular glaucoma. J Glaucoma (2009) 0.99
Factors associated with anterior chamber narrowing with age: an optical coherence tomography study. Invest Ophthalmol Vis Sci (2012) 0.97
Structure-function relationship of the macular visual field sensitivity and the ganglion cell complex thickness in glaucoma. Invest Ophthalmol Vis Sci (2012) 0.97
Macular and retinal nerve fiber layer thickness: which is more helpful in the diagnosis of glaucoma? Invest Ophthalmol Vis Sci (2011) 0.97
Factors associated with the signal strengths obtained by spectral domain optical coherence tomography. Korean J Ophthalmol (2012) 0.96
Prevalence and characteristics of glaucoma among Korean adults. Korean J Ophthalmol (2011) 0.95
Detection of glaucoma by spectral domain-scanning laser ophthalmoscopy/optical coherence tomography (SD-SLO/OCT) and time domain optical coherence tomography. J Glaucoma (2011) 0.94
Progression of retinal nerve fiber layer thinning in glaucoma assessed by cirrus optical coherence tomography-guided progression analysis. Curr Eye Res (2013) 0.94
Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography. Jpn J Ophthalmol (2011) 0.92
Usefulness of macular thickness derived from spectral-domain optical coherence tomography in the detection of glaucoma progression. Invest Ophthalmol Vis Sci (2013) 0.91
Imaging of the lamina cribrosa in glaucoma: perspectives of pathogenesis and clinical applications. Curr Eye Res (2013) 0.91
Relationship between scanning laser polarimetry with enhanced corneal compensation and with variable corneal compensation. Korean J Ophthalmol (2008) 0.91
Anterior chamber measurements by pentacam and AS-OCT in eyes with normal open angles. Korean J Ophthalmol (2008) 0.89
Mutation spectrum of CYP1B1 and MYOC genes in Korean patients with primary congenital glaucoma. Mol Vis (2011) 0.89
Circadian (24-hour) pattern of intraocular pressure and visual field damage in eyes with normal-tension glaucoma. Invest Ophthalmol Vis Sci (2012) 0.89
Scanning laser polarimetry with variable corneal compensation in the area of apparently normal hemifield in eyes with normal-tension glaucoma. Ophthalmology (2006) 0.89
Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study. Jpn J Ophthalmol (2011) 0.88
Progression detection in different stages of glaucoma: mean deviation versus visual field index. Jpn J Ophthalmol (2011) 0.87
Interpretation of outer retina appearance in high-resolution optical coherence tomography. Am J Ophthalmol (2009) 0.86
Effect of age on anterior chamber angle configuration in Asians determined by anterior segment optical coherence tomography; clinic-based study. Acta Ophthalmol (2010) 0.86
Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens. J Cataract Refract Surg (2010) 0.85
Factors affecting ocular pulse amplitude in eyes with open angle glaucoma and glaucoma-suspect eyes. Acta Ophthalmol (2010) 0.85
Characterization of peripapillary atrophy using spectral domain optical coherence tomography. Korean J Ophthalmol (2010) 0.85
Implications of Optic Disc Tilt in the Progression of Primary Open-Angle Glaucoma. Invest Ophthalmol Vis Sci (2015) 0.84
Detection of macular and circumpapillary structural loss in normal hemifield areas of glaucomatous eyes with localized visual field defects using spectral-domain optical coherence tomography. Graefes Arch Clin Exp Ophthalmol (2011) 0.84
Dynamic changes in anterior segment (AS) parameters in eyes with primary angle closure (PAC) and PAC glaucoma and open-angle eyes assessed using AS optical coherence tomography. Invest Ophthalmol Vis Sci (2012) 0.84
Retinal nerve fiber layer measurement variability with spectral domain optical coherence tomography. Korean J Ophthalmol (2012) 0.83
Comparison between dynamic contour tonometry and Goldmann applanation tonometry. Korean J Ophthalmol (2009) 0.83
Rates and patterns of macular and circumpapillary retinal nerve fiber layer thinning in preperimetric and perimetric glaucomatous eyes. J Glaucoma (2015) 0.82
Ocular pulse amplitude as a dynamic parameter and its relationship with 24-h intraocular pressure and blood pressure in glaucoma. Exp Eye Res (2013) 0.82
A hierarchical cluster analysis of primary angle closure classification using anterior segment optical coherence tomography parameters. Invest Ophthalmol Vis Sci (2013) 0.81
Circadian pattern of intraocular pressure fluctuations in young myopic eyes with open-angle glaucoma. Invest Ophthalmol Vis Sci (2014) 0.80
Ceramide-induced apoptosis in rabbit corneal fibroblasts. Cornea (2005) 0.80
Mitomycin C, ceramide, and 5-fluorouracil inhibit corneal haze and apoptosis after PRK. Cornea (2006) 0.80
Pharmacokinetics. Ophthalmology (2009) 0.80
Comparison of peripapillary retinal nerve fiber layer thickness measured by spectral vs. time domain optical coherence tomography. Curr Eye Res (2010) 0.80
Comparison of retinal nerve fibre layer thickness measurements calculated by the optic nerve head map (NHM4) and RNFL3.45 modes of spectral-domain optical coherence tomography (RTVue-100). Br J Ophthalmol (2010) 0.80
Evaluation for safety of cultured corneal fibroblasts with cotreatment of alcohol and mitomycin C. Invest Ophthalmol Vis Sci (2004) 0.80
Influence of blue light-filtering intraocular lenses on retinal nerve fiber layer measurements by spectral-domain optical coherence tomography. Curr Eye Res (2011) 0.80
Is Myopic Optic Disc Appearance a Risk Factor for Rapid Progression in Medically Treated Glaucomatous Eyes With Confirmed Visual Field Progression? J Glaucoma (2016) 0.79
Discrepancy between optic disc and nerve fiber layer assessment and optical coherence tomography in detecting glaucomatous progression. Jpn J Ophthalmol (2013) 0.79
Glaucoma progression in eyes with a history of refractive corneal surgery. Invest Ophthalmol Vis Sci (2012) 0.79
Clinical results of modified anterior chamber tube shunt to an encircling band surgery for uncontrolled intraocular pressure. J Glaucoma (2013) 0.78
Comparison between deviation map algorithm and peripapillary retinal nerve fiber layer measurements using Cirrus HD-OCT in the detection of localized glaucomatous visual field defects. J Glaucoma (2012) 0.78
Hypertensive Phase Following Silicone Plate Ahmed Glaucoma Valve Implantation. J Glaucoma (2016) 0.78
Glaucoma progression detection by retinal nerve fiber layer measurement using scanning laser polarimetry: event and trend analysis. Korean J Ophthalmol (2012) 0.78
Glaucoma diagnostic performance of humphrey matrix and standard automated perimetry. Jpn J Ophthalmol (2009) 0.78