Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code.

PubWeight™: 0.77‹?›

🔗 View Article (PMID 21573984)

Published in Radiat Environ Biophys on May 15, 2011

Authors

Ali Asghar Parach1, Hossein Rajabi, Mohammad Ali Askari

Author Affiliations

1: Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, P.O. Box 14115-331, Tehran, Iran.

Articles cited by this

GATE: a simulation toolkit for PET and SPECT. Phys Med Biol (2004) 7.88

OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med (2005) 7.25

MIRDOSE: personal computer software for internal dose assessment in nuclear medicine. J Nucl Med (1996) 3.32

MIRD pamphlet no. 16: Techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates. J Nucl Med (1999) 2.41

Voxel-based computational models of real human anatomy: a review. Radiat Environ Biophys (2004) 1.87

Patient-specific dosimetry for 131I thyroid cancer therapy using 124I PET and 3-dimensional-internal dosimetry (3D-ID) software. J Nucl Med (2004) 1.76

Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation. J Nucl Med (2005) 1.69

Hybrid computational phantoms for medical dose reconstruction. Radiat Environ Biophys (2009) 1.57

Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. J Nucl Med (1969) 1.52

Dosimetry of internal emitters. J Nucl Med (2005) 1.41

Monte Carlo simulations of absorbed dose in a mouse phantom from 18-fluorine compounds. Med Phys (2007) 1.39

A 3-dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy: evaluation for (131)I using monte carlo simulation. J Nucl Med (2002) 1.35

Monte Carlo MCNP-4B-based absorbed dose distribution estimates for patient-specific dosimetry. J Nucl Med (2001) 1.28

Implementation of a Monte Carlo dosimetry method for patient-specific internal emitter therapy. Med Phys (1997) 1.10

MIRD Pamphlet No 19: absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidney. J Nucl Med (2003) 1.09

MIRD Pamphlet No. 15: Radionuclide S values in a revised dosimetric model of the adult head and brain. Medical Internal Radiation Dose. J Nucl Med (1999) 1.05

The MIRD perspective 1999. Medical Internal Radiation Dose Committee. J Nucl Med (1999) 1.03

A Monte Carlo approach to patient-specific dosimetry. Med Phys (1996) 1.00

Implementation and evaluation of patient-specific three-dimensional internal dosimetry. J Nucl Med (1997) 0.95

Validation of a dose deposited by low-energy photons using GATE/GEANT4. Phys Med Biol (2008) 0.93

The application of voxel phantoms to the internal dosimetry of radionuclides. Radiat Prot Dosimetry (2003) 0.88

OEDIPE: a personalized dosimetric tool associating voxel-based models with MCNPX. Cancer Biother Radiopharm (2005) 0.85

Patient-specific dosimetry using quantitative SPECT imaging and three-dimensional discrete Fourier transform convolution. J Nucl Med (1997) 0.84

Update: the case for patient-specific dosimetry in radionuclide therapy. Cancer Biother Radiopharm (2008) 0.84

Comparison of internal radiation doses estimated by MIRD and voxel techniques for a "family" of phantoms. Eur J Nucl Med (2000) 0.83

S-values calculated from a tomographic head/brain model for brain imaging. Phys Med Biol (2004) 0.81

Construction of a computed tomographic phantom for a Japanese male adult and dose calculation system. Radiat Environ Biophys (2001) 0.80

Application of the ICRP/ICRU reference computational phantoms to internal dosimetry: calculation of specific absorbed fractions of energy for photons and electrons. Phys Med Biol (2010) 0.79

Practical aspects of Monte Carlo simulation of charged particle transport: mixed algorithms and variance reduction techniques. Radiat Environ Biophys (1999) 0.76

Implementing dosimetry in GATE: dose-point kernel validation with GEANT4 4.8.1. Cancer Biother Radiopharm (2007) 0.76

Developments in the internal dosimetry of radiopharmaceuticals. Radiat Prot Dosimetry (2003) 0.76

Dosimetry calculations on a tissue level by using the MCNP4c2 Monte Carlo code. Cancer Biother Radiopharm (2005) 0.75

Overview of dosimetry for Systemic Targeted Radionuclide Therapy (STaRT). Int J Radiat Oncol Biol Phys (2006) 0.75

Diversification of existing reference phantoms in nuclear medicine: Calculation of specific absorbed fractions for 21 mathematical phantoms and validation through dose estimates resulting from the administration of (18)F-FDG. Cancer Biother Radiopharm (2008) 0.75

Beta voxel S values for internal emitter dosimetry. Med Phys (2003) 0.75

MCNPX internal dosimetry studies based on the NORMAN-05 voxel model. Radiat Prot Dosimetry (2007) 0.75

Articles by these authors

Radiolabeling of trastuzumab with 177Lu via DOTA, a new radiopharmaceutical for radioimmunotherapy of breast cancer. Nucl Med Biol (2009) 0.89

Paired organs-should they be treated jointly or separately in internal dosimetry? Med Phys (2011) 0.85

177Lu labeling of Herceptin and preclinical validation as a new radiopharmaceutical for radioimmunotherapy of breast cancer. Nucl Med Biol (2010) 0.81

Toxicity of trastuzumab labeled 177Lu on MCF7 and SKBr3 cell lines. Appl Radiat Isot (2010) 0.80

Breast tumor targeting with (99m)Tc-HYNIC-PR81 complex as a new biologic radiopharmaceutical. Nucl Med Biol (2008) 0.78

Effect of respiratory motion on quantitative myocardial gated SPECT: a simulation study. Ann Nucl Med (2009) 0.77

Quantification and reduction of attenuation related artifacts in SPET by applying attenuation model during iterative image reconstruction: a Monte Carlo study. Hell J Nucl Med (2011) 0.77

Preparation and biological evaluation of (177)Lu conjugated PR81 for radioimmunotherapy of breast cancer. Nucl Med Biol (2011) 0.76

The International Atomic Energy Agency software package for the analysis of scintigraphic renal dynamic studies: a tool for the clinician, teacher, and researcher. Semin Nucl Med (2011) 0.75

Respiratory motion detection and correction in ECG-gated SPECT: a new approach. Korean J Radiol (2008) 0.75

Optimized energy window configuration for 201Tl imaging. J Nucl Med Technol (2008) 0.75

Correction of head movements in positron emission tomography using point source tracking system: a simulation study. Ann Nucl Med (2011) 0.75

Fusion of PET and CT images using wavelet transform. Hell J Nucl Med (2009) 0.75

Comparison of (99m)Tc-labeled PR81 and its F(ab')₂ fragments as radioimmunoscintigraphy agents for breast cancer imaging. Ann Nucl Med (2011) 0.75

The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images. Hell J Nucl Med (2012) 0.75

The effect of filtrating and reconstruction method on the left ventricular ejection fraction derived from GSPET: a statistical comparison of angiography and echocardiography. Ann Nucl Med (2008) 0.75

Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study. Nucl Med Commun (2012) 0.75

Assessment of the wavelet transform in reduction of noise from simulated PET images. J Nucl Med Technol (2009) 0.75