Is Near-Infrared Spectroscopy a Reliable Method to Evaluate Clamping Ischemia during Carotid Surgery?

PubWeight™: 0.91‹?›

🔗 View Article (PMC 3216275)

Published in Stroke Res Treat on November 09, 2011

Authors

Luciano Pedrini1, Filippo Magnoni, Luigi Sensi, Emilio Pisano, Maria Sandra Ballestrazzi, Maria Rosaria Cirelli, Alessandro Pilato

Author Affiliations

1: Operative Unit of Vascular Surgery, Department of Surgery, Maggiore Hospital of Bologna, 40133 Bologna, Italy.

Articles cited by this

Cerebral oxygen desaturation predicts cognitive decline and longer hospital stay after cardiac surgery. Ann Thorac Surg (2009) 2.26

Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy. Stroke (1998) 2.18

ESVS guidelines. Invasive treatment for carotid stenosis: indications, techniques. Eur J Vasc Endovasc Surg (2009) 2.01

The role of cerebral oximetry in combination with awake testing in patients undergoing carotid endarterectomy under local anaesthesia. Eur J Vasc Endovasc Surg (2011) 1.50

Monitoring and cerebral protection during carotid endarterectomy. Br J Surg (1992) 1.43

Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials. Anesthesiology (2007) 1.37

A comparison of the INVOS 4100 and the NIRO 300 near-infrared spectrophotometers. Anesth Analg (2002) 1.33

Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy. Anesthesiology (2000) 1.21

A comparison of cerebral oxygenation as measured by the NIRO 300 and the INVOS 5100 Near-Infrared Spectrophotometers. Anaesthesia (2002) 1.12

Transcranial regional cerebral oxygen saturation monitoring during carotid endarterectomy as a predictor of postoperative hyperperfusion. Neurosurgery (2003) 1.04

Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients. J Vasc Surg (2007) 1.00

Benefits, shortcomings, and costs of EEG monitoring. Ann Surg (1985) 0.94

Near infrared spectroscopy monitoring during carotid endarterectomy: which threshold value is critical? Eur J Vasc Endovasc Surg (2004) 0.91

Routine or selective carotid artery shunting for carotid endarterectomy (and different methods of monitoring in selective shunting). Cochrane Database Syst Rev (2002) 0.90

Light-reflective cerebral oximetry and jugular bulb venous oxygen saturation during carotid endarterectomy. Br J Surg (1994) 0.88

The effectiveness of regional cerebral oxygen saturation monitoring using near-infrared spectroscopy in carotid endarterectomy. J Clin Neurosci (2003) 0.88

The differing effects of regional and general anaesthesia on cerebral metabolism during carotid endarterectomy. Eur J Vasc Endovasc Surg (1996) 0.88

Recent developments in cerebral monitoring--near-infrared light spectroscopy. An overview. Eur J Vasc Endovasc Surg (1996) 0.83

Cerebral oximetry during carotid clamping: is blood pressure raising necessary? J Cardiovasc Med (Hagerstown) (2010) 0.83

Comments regarding 'the role of cerebral oximetry in combination with awake testing in patients undergoing carotid endarterectomy under local anaesthesia'. Eur J Vasc Endovasc Surg (2011) 0.80