Computer-assisted total knee arthroplasty: impact of the surgeon's experience on the component placement.

PubWeight™: 0.77‹?›

🔗 View Article (PMID 23229459)

Published in Arch Orthop Trauma Surg on December 11, 2012

Authors

Richard Ballas1, Rémi Philippot, Jean-Loup Cartier, Bertrand Boyer, Frédéric Farizon

Author Affiliations

1: Department of Orthopedic Surgery, University of Reunion Island, Hospital of Saint-Pierre, BP 350, Saint Pierre Cedex, France. richardballas@yahoo.fr

Articles citing this

Computer Assisted Total Knee Arthroplasty: Does it Make a Difference? Maedica (Buchar) (2013) 0.77

Articles by these authors

The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop (2008) 2.03

Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips. Int Orthop (2011) 1.53

Intraprosthetic dislocation: a specific complication of the dual-mobility system. Clin Orthop Relat Res (2012) 1.50

Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements. Clin Orthop Relat Res (2011) 1.05

Chronic Achilles tendon rupture reconstruction using a modified flexor hallucis longus transfer. Int Orthop (2009) 1.02

Letter to the editor: Staphylococcus aureus screening and decolonization in orthopaedic surgery and reduction of surgical site infections. Clin Orthop Relat Res (2013) 0.99

Study of patellar kinematics after reconstruction of the medial patellofemoral ligament. Clin Biomech (Bristol, Avon) (2011) 0.88

Rotator cuff strength in recurrent anterior shoulder instability. J Bone Joint Surg Am (2011) 0.87

Repeat revision of anterior cruciate ligament reconstruction: a retrospective review of management and outcome of 10 patients with an average 3-year follow-up. Am J Sports Med (2009) 0.80

Real frequency of ordinary and atypical sub-trochanteric and diaphyseal fractures in France based on X-rays and medical file analysis. Joint Bone Spine (2012) 0.79

Seven-year results of a press-fit, hydroxyapatite-coated double mobility acetabular component in patients aged 65 years or older. Eur J Orthop Surg Traumatol (2012) 0.75

Cementoplasty in the treatment of avascular necrosis of the hip. J Rheumatol (2009) 0.75

Intravenous Tranexamic Acid Bolus plus Infusion Is Not More Effective than a Single Bolus in Primary Hip Arthroplasty: A Randomized Controlled Trial. Anesthesiology (2017) 0.75