Published in J Contemp Brachytherapy on April 03, 2014
Tissue composition effect on dose distribution in neutron brachytherapy/neutron capture therapy. Rep Pract Oncol Radiother (2015) 0.86
A Monte Carlo study on dose distribution evaluation of Flexisource (192)Ir brachytherapy source. Rep Pract Oncol Radiother (2015) 0.78
Effect of tissue composition on dose distribution in electron beam radiotherapy. J Biomed Phys Eng (2015) 0.75
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys (2004) 7.32
Monte Carlo modelling of external radiotherapy photon beams. Phys Med Biol (2003) 2.11
The evolution of brachytherapy treatment planning. Med Phys (2009) 1.50
A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO. Med Phys (2011) 1.34
Supplement to the 2004 update of the AAPM Task Group No. 43 Report. Med Phys (2007) 1.28
Anniversary paper: past and current issues, and trends in brachytherapy physics. Med Phys (2008) 1.23
Cancer nanotechnology: application of nanotechnology in cancer therapy. Drug Discov Today (2010) 1.22
Comparison of (60)Co and (192)Ir sources in HDR brachytherapy. J Contemp Brachytherapy (2011) 1.13
Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation. Med Phys (2012) 1.12
Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer. J Contemp Brachytherapy (2012) 1.08
Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source. Med Phys (2007) 1.01
An EGSnrc Monte Carlo-calculated database of TG-43 parameters. Med Phys (2008) 0.98
Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources. Med Phys (2006) 0.97
Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques. J Contemp Brachytherapy (2012) 0.95
A discretized approach to determining TG-43 brachytherapy dosimetry parameters: case study using Monte Carlo calculations for the MED3633 103Pd source. Appl Radiat Isot (2001) 0.95
Monte Carlo modeling of Co HDR brachytherapy source in water and in different solid water phantom materials. J Med Phys (2010) 0.93
Effect of inhomogeneities and source position on dose distribution of nucletron high dose rate Ir-192 brachytherapy source by Monte Carlo simulation. J Cancer Res Ther (2010) 0.91
Robust calculation of effective atomic numbers: the Auto-Z(eff) software. Med Phys (2012) 0.90
Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study. Med Phys (1994) 0.89
A formulation of tissue- and water-equivalent materials using the stoichiometric analysis method for CT-number calibration in radiotherapy treatment planning. Phys Med Biol (2012) 0.88
Monte Carlo characterization of a new Yb-169 high dose rate source for brachytherapy application. Med Phys (2010) 0.86
Monte Carlo estimation of dose difference in lung from 192Ir brachytherapy due to tissue inhomogeneity. Radiat Prot Dosimetry (2011) 0.86
Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry. Phys Med Biol (2012) 0.86
A study on the dose distributions in various materials from an Ir-192 HDR brachytherapy source. PLoS One (2012) 0.86
A Monte Carlo study on tissue dose enhancement in brachytherapy: a comparison between gadolinium and gold nanoparticles. Australas Phys Eng Sci Med (2012) 0.84
Influence of phantom material and dimensions on experimental 192Ir dosimetry. Med Phys (2009) 0.82
Dosimetry characteristics of the Plus and 12i Gammamed PDR 192Ir sources. Med Phys (2001) 0.78
Effects of breast-air and breast-lung interfaces on the dose rate at the planning target volume of a MammoSite catheter for Yb-169 and Ir-192 HDR sources. Med Phys (2010) 0.78
A Monte Carlo study on dose distribution evaluation of Flexisource (192)Ir brachytherapy source. Rep Pract Oncol Radiother (2015) 0.78
A comparison study on various low energy sources in interstitial prostate brachytherapy. J Contemp Brachytherapy (2016) 0.75
Evaluation of (101)Rh as a brachytherapy source. J Contemp Brachytherapy (2015) 0.75
Comparison of the hypothetical (57)Co brachytherapy source with the (192)Ir source. Contemp Oncol (Pozn) (2016) 0.75
Evaluation of the accuracy of various dose calculation algorithms of a commercial treatment planning system in the presence of hip prosthesis and comparison with Monte Carlo. J Cancer Res Ther (2017) 0.75