Published in IEEE Trans Biomed Circuits Syst on October 28, 2014
Experimental implementation of array-compressed parallel transmission at 7 tesla. Magn Reson Med (2016) 0.77
In vivo MR imaging with simultaneous RF transmission and reception. Magn Reson Med (2016) 0.75
New resonator geometries for ICE decoupling of loop arrays. J Magn Reson (2017) 0.75
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images. Magn Reson Med (2001) 7.05
9.4T human MRI: preliminary results. Magn Reson Med (2006) 2.98
Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. Magn Reson Imaging (2001) 2.84
Imaging at high magnetic fields: initial experiences at 4 T. Magn Reson Q (1993) 2.14
Efficient high-frequency body coil for high-field MRI. Magn Reson Med (2004) 2.07
Magnetic resonance imaging at ultrahigh fields. IEEE Trans Biomed Eng (2014) 1.04
Automatic tuned MRI RF coil for multinuclear imaging of small animals at 3T. J Magn Reson (2002) 0.93
Automatic tuning and matching of a small multifrequency saddle coil at 4.7 T. Magn Reson Med (2004) 0.90
Automatic probe tuning and matching. Magn Reson Med (1998) 0.90
Automatic tuning of flexible interventional RF receiver coils. Magn Reson Med (2005) 0.85
9.4T human MRI: preliminary results. Magn Reson Med (2006) 2.98
Proton T2 relaxation study of water, N-acetylaspartate, and creatine in human brain using Hahn and Carr-Purcell spin echoes at 4T and 7T. Magn Reson Med (2002) 2.09
Eliminating spurious lipid sidebands in 1H MRS of breast lesions. Magn Reson Med (2002) 1.30
Improved gradient-echo 3D magnetic resonance imaging using pseudo-echoes created by frequency-swept pulses. Magn Reson Med (2006) 1.24
On- and off-resonance T(1rho) MRI in acute cerebral ischemia of the rat. Magn Reson Med (2003) 1.12
Radio frequency heating at 9.4T (400.2 MHz): in vivo thermoregulatory temperature response in swine. Magn Reson Med (2009) 0.90
Heating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 T transceive volume head coil. Phys Med Biol (2012) 0.88
Aqueous sample in an EPR cavity: sensitivity considerations. J Magn Reson (2004) 0.84
Cardiac imaging at 7 Tesla: Single- and two-spoke radiofrequency pulse design with 16-channel parallel excitation. Magn Reson Med (2013) 0.84
A method to localize RF B₁ field in high-field magnetic resonance imaging systems. IEEE Trans Biomed Eng (2012) 0.81
Stepped impedance resonators for high-field magnetic resonance imaging. IEEE Trans Biomed Eng (2014) 0.75
Pseudoinverse method for modal solutions of open dielectric waveguides. Opt Lett (2009) 0.75
Analysis of open dielectric waveguides using the finite-element penalty method. Opt Lett (2008) 0.75