Vertebroplasty Using Calcium Triglyceride Bone Cement (Kryptonite™) for Vertebral Compression Fractures. A Single-Centre Preliminary Study of Outcomes at One-Year Follow-up.

PubWeight™: 0.84‹?›

🔗 View Article (PMC 4243227)

Published in Interv Neuroradiol on October 17, 2014

Authors

Gianluigi Guarnieri1, Mario Tecame2, Roberto Izzo3, Pasquale Vassallo3, Angela Sardaro2, Francesca Iasiello2, Carlo Cavaliere3, Mario Muto3

Author Affiliations

1: Neuroradiology Service, Cardarelli Hospital; Naples, Italy - gianluigiguarnieri@hotmail.it.
2: Radiology Service, Seconda Università degli Studi di Napoli SUN; Naples, Italy.
3: Neuroradiology Service, Cardarelli Hospital; Naples, Italy.

Articles cited by this

Risk of new vertebral fracture in the year following a fracture. JAMA (2001) 6.17

[Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty]. Neurochirurgie (1987) 5.88

Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol (1998) 3.69

The clinical consequences of vertebral compression fracture. Bone (1992) 2.92

Percutaneous vertebroplasty: state of the art. Radiographics (1998) 2.29

Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine (Phila Pa 1976) (2001) 2.22

Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J Neurosurg (2002) 1.65

Vertebroplasty and kyphoplasty: filler materials. Spine J (2005) 1.38

Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J (2011) 1.37

Injectable bone cements for use in vertebroplasty and kyphoplasty: state-of-the-art review. J Biomed Mater Res B Appl Biomater (2006) 1.20

The risk of new osteoporotic vertebral compression fractures in the year after percutaneous vertebroplasty. J Vasc Interv Radiol (2006) 1.17

Risk factors of developing new symptomatic vertebral compression fractures after percutaneous vertebroplasty in osteoporotic patients. Eur Spine J (2006) 1.14

[Percutaneous injection of methyl-metacrylate in osteoporosis and severe vertebral osteolysis (Galibert's technic)]. Ann Chir (1989) 1.14

Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine (Phila Pa 1976) (2002) 1.12

Mechanical efficacy of vertebroplasty: influence of cement type, BMD, fracture severity, and disc degeneration. Bone (2007) 1.09

The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine (Phila Pa 1976) (1999) 1.07

Injection biomechanics of bone cements used in vertebroplasty. Biomed Mater Eng (2004) 1.06

New symptomatic vertebral compression fractures within a year following vertebroplasty in osteoporotic women. AJNR Am J Neuroradiol (2005) 1.04

Vertebroplasty and kyphoplasty: friends or foes? Radiol Med (2008) 0.97

Cranial reconstruction using bioabsorbable calcified triglyceride bone cement. J Craniofac Surg (2010) 0.92

Effect of cement volume and placement on mechanical-property restoration resulting from vertebroplasty. AJNR Am J Neuroradiol (2005) 0.90

Osteoporotic vertebral compression fractures augmentation by injectable partly resorbable ceramic bone substitute (Cerament™|SPINE SUPPORT): a prospective nonrandomized study. Neuroradiology (2011) 0.89

Vertebroplasty Using Calcium Phosphate Cement for Osteoporotic Vertebral Fractures: Study of Outcomes at a Minimum Follow-up of Two Years. Asian Spine J (2012) 0.87

Position statement on percutaneous vertebral augmentation: a consensus statement developed by the American Society of Interventional and Therapeutic Neuroradiology, Society of Interventional Radiology, American Association of Neurological Surgeons/Congress of Neurological Surgeons, and American Society of Spine Radiology. AJNR Am J Neuroradiol (2007) 0.84

Articles by these authors

Multisegmental diffuse intradural extramedullary ependymoma. An extremely rare case. Neuroradiol J (2014) 0.75