Jugular vein distensibility predicts fluid responsiveness in septic patients.

PubWeight™: 0.91‹?›

🔗 View Article (PMC 4301660)

Published in Crit Care on December 05, 2014

Authors

Fabio Guarracino1, Baldassarre Ferro2, Francesco Forfori3, Pietro Bertini4, Luana Magliacano5, Michael R Pinsky6

Author Affiliations

1: Department of Anesthesia and Critical Care Medicine, Cardiothoracic Anesthesia and Intensive Care Medicine, Azienda Ospedaliero Universitaria Pisana, Via Paradisa, 2 56123, Pisa, Italy. fabiodoc64@hotmail.com.
2: Department of Anesthesia and Critical Care Medicine, Cardiothoracic Anesthesia and Intensive Care Medicine, Azienda Ospedaliero Universitaria Pisana, Via Paradisa, 2 56123, Pisa, Italy. baldoferro81@gmail.com.
3: Department of Anesthesia and Critical Care Medicine, Anestesia e Rianimazione Universitaria IV, Azienda Ospedaliero Universitaria Pisana, Via Paradisa, 2 56123, Pisa, Italy. forforiden@libero.it.
4: Department of Anesthesia and Critical Care Medicine, Cardiothoracic Anesthesia and Intensive Care Medicine, Azienda Ospedaliero Universitaria Pisana, Via Paradisa, 2 56123, Pisa, Italy. pietro.bertini@gmail.com.
5: Department of Anesthesia and Critical Care Medicine, Anestesia e Rianimazione Universitaria IV, Azienda Ospedaliero Universitaria Pisana, Via Paradisa, 2 56123, Pisa, Italy. luanam84@hotmail.com.
6: Department of Critical Care Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA, USA. pinskymr@upmc.edu.

Articles cited by this

Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med (2013) 17.37

Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest (2008) 6.25

Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med (2000) 5.53

Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach. Anesthesiology (2011) 4.24

Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med (2007) 4.21

Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med (2004) 3.64

Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med (2004) 3.16

Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth (2005) 2.03

Functional hemodynamic monitoring. Crit Care (2005) 1.90

Point-of-care ultrasound to estimate central venous pressure: a comparison of three techniques. Crit Care Med (2013) 1.60

Ernest Henry Starling, his predecessors, and the "Law of the Heart". Circulation (2002) 1.53

Using internal jugular pulsations as a manometer for right atrial pressure measurements. Cardiology (2000) 0.92

Thermodilution vs pressure recording analytical method in hemodynamic stabilized patients. J Crit Care (2013) 0.90

The jugular venous pressure revisited. Cleve Clin J Med (2013) 0.86

Non-invasive method for the rapid assessment of central venous pressure: description and validation by a single examiner. West J Emerg Med (2008) 0.85

Simplified evaluation of the jugular venous pressure: significance of inspiratory collapse of jugular veins. Mo Med (2012) 0.84