Improvement in B1+ Homogeneity and Average Flip Angle Using Dual-Source Parallel RF Excitation for Cardiac MRI in Swine Hearts.

PubWeight™: 0.77‹?›

🔗 View Article (PMC 4593605)

Published in PLoS One on October 05, 2015

Authors

Michael Schär1, Haiyan Ding2, Daniel A Herzka3

Author Affiliations

1: Russell H. Morgan Department of Radiology and Radiological Science, Division of Magnetic Resonance Research, Johns Hopkins University, Baltimore, Maryland, United States of America; Clinical Science MRI, Philips Healthcare, Cleveland, Ohio, United States of America.
2: Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States of America; Biomedical Engineering, Tsinghua University, Beijing, China.
3: Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Maryland, United States of America.

Articles cited by this

In vivo heating of pacemaker leads during magnetic resonance imaging. Eur Heart J (2004) 3.38

Saturated double-angle method for rapid B1+ mapping. Magn Reson Med (2006) 3.15

Simultaneous B(0)- and B(1)+-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T. Magn Reson Med (2010) 1.50

Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T. J Magn Reson Imaging (2003) 1.44

Measurement and characterization of RF nonuniformity over the heart at 3T using body coil transmission. J Magn Reson Imaging (2008) 1.39

Real-time magnetic resonance imaging-guided radiofrequency atrial ablation and visualization of lesion formation at 3 Tesla. Heart Rhythm (2010) 1.37

Simulation of B1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field. J Magn Reson (1997) 1.37

Cardiovascular magnetic resonance at 3.0 T: current state of the art. J Cardiovasc Magn Reson (2010) 1.20

Dual-source radiofrequency transmission with patient-adaptive local radiofrequency shimming for 3.0-T cardiac MR imaging: initial experience. Radiology (2012) 1.05

Evaluation of a subject specific dual-transmit approach for improving B1 field homogeneity in cardiovascular magnetic resonance at 3T. J Cardiovasc Magn Reson (2013) 0.96

Body and cardiovascular MR imaging at 3.0 T. Radiology (2007) 0.96

Impact of number of channels on RF shimming at 3T. MAGMA (2013) 0.95

Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine. J Cardiovasc Magn Reson (2012) 0.92

Impact of 3.0 T Cardiac MR Imaging Using Dual-Source Parallel Radiofrequency Transmission with Patient-Adaptive B1 Shimming. PLoS One (2013) 0.90

Cardiac magnetic resonance at high field: promises and problems. Curr Probl Diagn Radiol (2008) 0.84

Three-dimensional whole-heart T2 mapping at 3T. Magn Reson Med (2014) 0.84

Animal models of atherosclerosis and magnetic resonance imaging for monitoring plaque progression. Vascular (2014) 0.82

Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience. J Cardiovasc Magn Reson (2014) 0.79

Three-dimensional regional strain analysis in porcine myocardial infarction: a 3T magnetic resonance tagging study. J Cardiovasc Magn Reson (2012) 0.79

Dual-source RF transmission in cardiac SSFP imaging at 3 T: systematic spatial evaluation of image quality improvement compared to conventional RF transmission. Clin Imaging (2014) 0.78

Dynamic manganese-enhanced magnetic resonance imaging can detect chronic cryoinjury-induced infarction in pig hearts in vivo. Contrast Media Mol Imaging (2011) 0.78