Cortical hypertrophy with a short, curved uncemented hip stem does not have any clinical impact during early follow-up.

PubWeight™: 0.82‹?›

🔗 View Article (PMC 4667403)

Published in BMC Musculoskelet Disord on December 01, 2015

Authors

Michael W Maier1, Marcus R Streit2, Moritz M Innmann3, Marlis Krüger4, Jan Nadorf5, J Philippe Kretzer6, Volker Ewerbeck7, Tobias Gotterbarm8

Author Affiliations

1: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Michael.maier@med.uni-heidelberg.de.
2: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Marcus.streit@med.uni-heidelberg.de.
3: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Moritz.innmann@med.uni-heidelberg.de.
4: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Marlis.krueger@med.uni-heidelberg.de.
5: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Jan.Nadorf@med.uni-heidelberg.de.
6: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Philippe.kretzer@med.uni-heidelberg.de.
7: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Volker.ewerbeck@med.uni-heidelberg.de.
8: Clinic for Orthopedics and Trauma Surgery, Heidelberg University Hospital, Schlierbacher Landstrasse 200a, 69118, Heidelberg, Germany. Tobias.gotterbarm@med.uni-heidelberg.de.

Articles cited by this

Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol (1988) 35.68

Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am (1969) 22.45

"Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res (1979) 11.43

Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res (1985) 9.85

Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am (1973) 8.60

Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br (1987) 4.72

Assessing activity in joint replacement patients. J Arthroplasty (1998) 3.35

Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br (2007) 1.97

Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register. Acta Orthop (2006) 1.74

The transgluteal approach to the hip joint. Arch Orthop Trauma Surg (1979) 1.68

A conservative femoral replacement for total hip arthroplasty. A prospective study. J Bone Joint Surg Br (2000) 1.67

Which is the best activity rating scale for patients undergoing total joint arthroplasty? Clin Orthop Relat Res (2008) 1.55

The case for porous-coated hip implants. The femoral side. Clin Orthop Relat Res (1990) 1.44

Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand (1995) 1.42

Thigh pain after cementless total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg (2002) 1.41

Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg Am (2008) 1.27

Survival of the cementless Spotorno stem in the second decade. Clin Orthop Relat Res (2009) 1.24

Instruments to assess physical activity in patients with osteoarthritis of the hip or knee: a systematic review of measurement properties. Osteoarthritis Cartilage (2011) 1.23

Mid-term results of a custom-made short proximal loading femoral component. J Bone Joint Surg Br (2010) 1.18

Bone remodelling in THA: A comparative DXA scan study between conventional implants and a new stemless femoral component. A preliminary report. Hip Int (2006) 1.15

New femoral designs: do they influence stress shielding? Clin Orthop Relat Res (2006) 1.15

Migration pattern of a short femoral neck preserving stem. Clin Orthop Relat Res (2006) 1.15

Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results. J Bone Joint Surg Am (2009) 1.11

Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant. Clin Biomech (Bristol, Avon) (2007) 1.06

Primary stability and strain distribution of cementless hip stems as a function of implant design. Clin Biomech (Bristol, Avon) (2011) 1.04

Accuracy of visually estimated bone mineralization in routine radiographs of the lower extremity. Skeletal Radiol (1988) 1.04

Effect of neck resection on torsional stability of cementless total hip replacement. Am J Orthop (Belle Mead NJ) (1995) 1.04

Interobserver variability in interpreting radiographic lucencies about total hip reconstructions. Clin Orthop Relat Res (1985) 1.03

Femoral neck preservation in total hip replacement. Ital J Orthop Traumatol (1993) 1.00

[Short-stemmed endoprostheses in total hip arthroplasty]. Orthopade (2007) 0.98

Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years. A concise follow-up of previous reports. J Bone Joint Surg Am (2008) 0.97

Cementless total hip arthroplasty with the rectangular titanium Zweymüller stem: a concise follow-up, at a minimum of twenty years, of previous reports. J Bone Joint Surg Am (2012) 0.96

Long-term (20- to 25-year) results of an uncemented tapered titanium femoral component and factors affecting survivorship. Clin Orthop Relat Res (2013) 0.96

A prospective cohort study on the short collum femoris-preserving (CFP) stem using RSA and DXA. Primary stability but no prevention of proximal bone loss in 27 patients followed for 2 years. Acta Orthop (2013) 0.95

Ultra-short stems with proximal load transfer: Clinical and radiographic results at five-year follow-up. Hip Int (2006) 0.92

Short stems for total hip arthroplasty: initial experience with the Fitmore stem. J Bone Joint Surg Br (2012) 0.92

Stress-related femoral cortical and cancellous bone density loss after collum femoris preserving uncemented total hip arthroplasty: a prospective 7-year follow-up with quantitative computed tomography. Arch Orthop Trauma Surg (2012) 0.91

Bone preservation with a conservative metaphyseal loading implant. Hip Int (2006) 0.90

Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger. J Arthroplasty (2006) 0.89

The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components. J Arthroplasty (1993) 0.85

Is diaphyseal stem fixation necessary for primary total hip arthroplasty in patients with osteoporotic bone (Class C bone)? J Arthroplasty (2012) 0.81

Use of the Fitmore® hip stem bone-preserving system for the minimally invasive anterior-supine approach in hip replacement. Am J Orthop (Belle Mead NJ) (2010) 0.79

Bone sparing surgical options for total hip replacement. Biomed Sci Instrum (2003) 0.79

Primary stability of the Fitmore stem: biomechanical comparison. Int Orthop (2013) 0.79

Potential errors inherent in quantitative densitometric analysis of orthopaedic radiographs. A study after total hip arthroplasty. J Bone Joint Surg Am (1987) 0.78