Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse.

PubWeight™: 0.75‹?›

🔗 View Article (PMID 27240363)

Published in Sensors (Basel) on May 26, 2016

Authors

Min-Ho Jun1, Young-Min Kim2, Jang-Han Bae3, Chang Jin Jung4, Jung-Hee Cho5, Young Ju Jeon6

Author Affiliations

1: KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea. mino@kiom.re.kr.
2: KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea. irobo77@kiom.re.kr.
3: KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea. fcbest11@kiom.re.kr.
4: KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea. traviswas@kiom.re.kr.
5: KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea. xtin@kiom.re.kr.
6: KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea. jyj92@kiom.re.kr.

Articles cited by this

Arterial stiffness, wave reflections, and the risk of coronary artery disease. Circulation (2003) 3.67

Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms. Am J Hypertens (2005) 2.09

A clinical study of the pulse wave characteristics at the three pulse diagnosis positions of chon, gwan and cheok. Evid Based Complement Alternat Med (2011) 1.62

Novel diagnostic algorithm for the floating and sunken pulse qualities and its clinical test. Evid Based Complement Alternat Med (2011) 1.19

Radial augmentation index: a useful and easily obtainable parameter for vascular aging. Am J Hypertens (2005) 1.12

Development of a radial pulse tonometric (RPT) sensor with a temperature compensation mechanism. Sensors (Basel) (2013) 1.11

Measurement of blood pressure using an arterial pulsimeter equipped with a Hall device. Sensors (Basel) (2011) 1.08

New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices. Evid Based Complement Alternat Med (2013) 1.05

Novel diagnostic model for the deficient and excess pulse qualities. Evid Based Complement Alternat Med (2011) 1.03

Temporal and spatial properties of arterial pulsation measurement using pressure sensor array. Evid Based Complement Alternat Med (2011) 1.00

Quantitative analysis of sensor for pressure waveform measurement. Biomed Eng Online (2010) 0.86

Comparison of Three Different Types of Wrist Pulse Signals by Their Physical Meanings and Diagnosis Performance. IEEE J Biomed Health Inform (2014) 0.80