Neurological Injury in Intermediate-Risk Transcatheter Aortic Valve Implantation.

PubWeight™: 0.78‹?›

🔗 View Article (PMID 27849158)

Published in J Am Heart Assoc on November 15, 2016

Authors

Jonathon P Fanning1,2,3, Allan J Wesley4,3, Darren L Walters5,6,2,3, Eamonn M Eeles7,3, Adrian G Barnett5,8, David G Platts5,6,2,3, Andrew J Clarke5,9,2, Andrew A Wong3,10, Wendy E Strugnell4, Cliona O'Sullivan5, Oystein Tronstad5,11, John F Fraser5,12,2,3

Author Affiliations

1: Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia jonathon_fanning@me.com.
2: The Heart & Lung Institute, Metro North Hospital and Health Service District, Brisbane, Queensland, Australia.
3: The University of Queensland, Herston, Queensland, Australia.
4: Department of Medical Imaging, The Prince Charles Hospital, Brisbane, Queensland, Australia.
5: Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.
6: Department of Cardiology, The Prince Charles Hospital, Brisbane, Queensland, Australia.
7: Department of Geriatrics, The Prince Charles Hospital, Brisbane, Queensland, Australia.
8: School of Public Health and Social Work, Queensland University of Technology, Brisbane, Queensland, Australia.
9: Department of Cardiothoracic Surgery, The Prince Charles Hospital, Brisbane, Queensland, Australia.
10: Department of Neurology, The Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia.
11: Department of Physiotherapy, The Prince Charles Hospital, Brisbane, Queensland, Australia.
12: Adult Intensive Care Unit, The Prince Charles Hospital, Brisbane, Queensland, Australia.

Articles cited by this

Frailty in older adults: evidence for a phenotype. J Gerontol A Biol Sci Med Sci (2001) 42.21

Regularization Paths for Generalized Linear Models via Coordinate Descent. J Stat Softw (2010) 38.65

The Montreal Cognitive Assessment, MoCA: a brief screening tool for mild cognitive impairment. J Am Geriatr Soc (2005) 27.90

Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med (2010) 22.04

Modeling valuations for EuroQol health states. Med Care (1997) 21.66

Clarifying confusion: the confusion assessment method. A new method for detection of delirium. Ann Intern Med (1990) 16.54

Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med (2011) 15.70

Guidelines on the management of valvular heart disease (version 2012). Eur Heart J (2012) 10.70

Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med (2016) 6.95

Development and evaluation of the Kansas City Cardiomyopathy Questionnaire: a new health status measure for heart failure. J Am Coll Cardiol (2000) 6.08

Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med (2014) 5.88

Frailty in relation to the accumulation of deficits. J Gerontol A Biol Sci Med Sci (2007) 5.20

2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Thorac Cardiovasc Surg (2014) 3.59

Health-related quality of life after transcatheter or surgical aortic valve replacement in high-risk patients with severe aortic stenosis: results from the PARTNER (Placement of AoRTic TraNscathetER Valve) Trial (Cohort A). J Am Coll Cardiol (2012) 3.29

Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Am Coll Cardiol (2012) 2.78

A chart-based method for identification of delirium: validation compared with interviewer ratings using the confusion assessment method. J Am Geriatr Soc (2005) 2.63

Transcatheter aortic valve implantation: assessing the learning curve. JACC Cardiovasc Interv (2011) 2.63

Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet (2016) 2.47

Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation (2010) 2.14

Is the Montreal Cognitive Assessment superior to the Mini-Mental State Examination to detect poststroke cognitive impairment? A study with neuropsychological evaluation. Stroke (2011) 2.09

Prevalence and 10-year outcomes of frailty in older adults in relation to deficit accumulation. J Am Geriatr Soc (2010) 2.06

Cerebral embolism following transcatheter aortic valve implantation: comparison of transfemoral and transapical approaches. J Am Coll Cardiol (2011) 2.02

Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging. J Am Coll Cardiol (2010) 1.98

What would make a definition of frailty successful? Age Ageing (2005) 1.84

Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery. J Am Coll Cardiol (2014) 1.80

Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients. EuroIntervention (2012) 1.73

Timing, predictive factors, and prognostic value of cerebrovascular events in a large cohort of patients undergoing transcatheter aortic valve implantation. Circulation (2012) 1.66

How accurate is the eyeball test?: a comparison of physician's subjective assessment versus statistical methods in estimating mortality risk after cardiac surgery. Circ Cardiovasc Qual Outcomes (2014) 1.41

Use of the Kansas City Cardiomyopathy Questionnaire for monitoring health status in patients with aortic stenosis. Circ Heart Fail (2012) 1.32

Measurement of post-operative cognitive dysfunction after cardiac surgery: a systematic review. Acta Anaesthesiol Scand (2010) 1.28

Clinical outcomes at 1 year following transcatheter aortic valve replacement. JAMA (2015) 1.23

The Montreal Cognitive Assessment is superior to the Mini-Mental State Examination in detecting patients at higher risk of dementia. Int Psychogeriatr (2012) 1.17

Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and trans-apical approaches using Edwards Sapiens valve. Eur J Cardiothorac Surg (2011) 1.03

Transitions in frailty states among community-living older adults and their associated factors. J Am Med Dir Assoc (2014) 1.03

Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status. Heart (2011) 1.02

Transapical aortic valve implantation in 100 consecutive patients: comparison to propensity-matched conventional aortic valve replacement. Eur Heart J (2010) 0.96

Risk assessment methods for cardiac surgery and intervention. Nat Rev Cardiol (2014) 0.93

Sequence-specific MR imaging findings that are useful in dating ischemic stroke. Radiographics (2012) 0.91

Emerging spectra of silent brain infarction. Stroke (2014) 0.90

Prognostic value of exercise capacity as evaluated by the 6-minute walk test in patients undergoing transcatheter aortic valve implantation. J Am Coll Cardiol (2013) 0.90

A new transcatheter aortic valve and percutaneous valve delivery system. J Am Coll Cardiol (2009) 0.89

First successful trans-catheter aortic valve implantation through ascending aorta using Edwards SAPIEN THV system. Eur J Cardiothorac Surg (2010) 0.87

Characterization of neurological injury in transcatheter aortic valve implantation: how clear is the picture? Circulation (2014) 0.87

Embolic cerebral insults after transapical aortic valve implantation detected by magnetic resonance imaging. JACC Cardiovasc Interv (2010) 0.86

Comparison of sedation and general anaesthesia for transcatheter aortic valve implantation on cerebral oxygen saturation and neurocognitive outcome†. Br J Anaesth (2015) 0.86

Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: a meta-analysis and systematic review of literature. J Am Coll Cardiol (2014) 0.84

Neurological damage after transcatheter aortic valve implantation compared with surgical aortic valve replacement in intermediate risk patients. Clin Res Cardiol (2015) 0.82

Challenges in cardiac device innovation: is neuroimaging an appropriate endpoint? Consensus from the 2013 Yale-UCL Cardiac Device Innovation Summit. BMC Med (2013) 0.80

Transcatheter aortic valve implantation (TAVI): valve design and evolution. Int J Cardiol (2013) 0.79

Consequence of cerebral embolism after transcatheter aortic valve implantation compared with contemporary surgical aortic valve replacement: effect on health-related quality of life. Circ Cardiovasc Interv (2015) 0.76