Magnet field profiling: analysis and correcting coil design.

PubWeight™: 3.57‹?› | Rank: Top 1%

🔗 View Article (PMID 6571436)

Published in Magn Reson Med on March 01, 1984

Authors

F Roméo, D I Hoult

Articles citing this

O-space imaging: Highly efficient parallel imaging using second-order nonlinear fields as encoding gradients with no phase encoding. Magn Reson Med (2010) 1.56

Magnetic field modeling with a set of individual localized coils. J Magn Reson (2010) 1.43

Dynamic multi-coil shimming of the human brain at 7 T. J Magn Reson (2011) 1.29

Multicoil shimming of the mouse brain. Magn Reson Med (2011) 1.23

Dynamic Shimming of the Human Brain at 7 Tesla. Concepts Magn Reson Part B Magn Reson Eng (2010) 1.11

Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging. Magn Reson Med (2011) 1.05

Volume parcellation for improved dynamic shimming. MAGMA (2008) 1.02

Split gradient coils for simultaneous PET-MRI. Magn Reson Med (2009) 1.01

Integrated RF/shim coil array for parallel reception and localized B0 shimming in the human brain. Neuroimage (2014) 0.99

Multi-coil magnetic field modeling. J Magn Reson (2013) 0.98

Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements. Magn Reson Med (2014) 0.98

Integrated parallel reception, excitation, and shimming (iPRES). Magn Reson Med (2013) 0.97

A 32-channel combined RF and B0 shim array for 3T brain imaging. Magn Reson Med (2015) 0.97

Optimization of static magnetic field homogeneity in the human and animal brain in vivo. Prog Nucl Magn Reson Spectrosc (2009) 0.91

Practical estimate of gradient nonlinearity for implementation of apparent diffusion coefficient bias correction. J Magn Reson Imaging (2014) 0.85

An Analytical Approach towards Passive Ferromagnetic Shimming Design for a High-Resolution NMR Magnet. Supercond Sci Technol (2015) 0.84

High resolution NMR spectroscopy of rat brain in vivo through indirect zero-quantum-coherence detection. J Magn Reson (2007) 0.82

Automatic high-order shimming using parallel columns mapping (PACMAP). Magn Reson Med (2009) 0.81

Radiofrequency pulse design using nonlinear gradient magnetic fields. Magn Reson Med (2014) 0.81

B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy. Anal Biochem (2016) 0.79

Multi-slice MRI with the dynamic multi-coil technique. NMR Biomed (2015) 0.79

Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data. Magn Reson Med (2013) 0.79

Performance evaluation of matrix gradient coils. MAGMA (2015) 0.79

3D gradient system for two B0 field directions in earth's field MRI. MAGMA (2013) 0.78

Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system. Med Phys (2008) 0.77

A Theoretical Design Approach for Passive Shimming of a Magic-Angle-Spinning NMR Magnet. IEEE Trans Appl Supercond (2016) 0.75

Analysis of Uniformity of Magnetic Field Generated by the Two-Pair Coil System. Appl Magn Reson (2013) 0.75

New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy. J Med Imaging (Bellingham) (2017) 0.75

Theory and development of biplanar active shim coils for a permanent NMR analyzer. PLoS One (2017) 0.75

The public multi-coil information (PUMCIN) policy. Magn Reson Med (2016) 0.75

Design of a mobile, homogeneous, and efficient electromagnet with a large field of view for neonatal low-field MRI. MAGMA (2016) 0.75

Challenges of short magnet design. MAGMA (2002) 0.75

Shielded gradients. And the general solution to the near field problem of electromagnet design. MAGMA (1999) 0.75

Articles by these authors

Observation of tissue metabolites using 31P nuclear magnetic resonance. Nature (1974) 4.13

The signal-to-noise ratio of the nuclear magnetic resonance experiment. 1976. J Magn Reson (2011) 3.81

Selective population inversion in NMR. Nature (1984) 2.24

Phosphorus nuclear magnetic resonance studies on normoxic and ischemic cardiac tissue. Proc Natl Acad Sci U S A (1976) 1.57

The field dependence of NMR imaging. I. Laboratory assessment of signal-to-noise ratio and power deposition. Magn Reson Med (1986) 1.35

Frequency dependence of 31P NMR linewidths in sonicated phospholipid vesicles: effects of chemical shift anisotropy. FEBS Lett (1974) 1.27

The field dependence of NMR imaging. II. Arguments concerning an optimal field strength. Magn Reson Med (1986) 1.23

Application of 31P NMR to model and biological membrane systems. FEBS Lett (1975) 1.19

A mobile high-field magnetic resonance system for neurosurgery. J Neurosurg (1999) 1.00

Quadrature detection in the laboratory frame. Magn Reson Med (1984) 0.94

Automatic probe tuning and matching. Magn Reson Med (1998) 0.90

Rotating frame zeugmatography. Philos Trans R Soc Lond B Biol Sci (1980) 0.81

The visualization of RF probe electric fields. Magn Reson Med (1993) 0.80

Probe with chest shielding for improved breast MRI. Magn Reson Med (2000) 0.77

NMR imaging techniques. Br Med Bull (1984) 0.75

Hyperthermia system combined with a magnetic resonance imaging unit. Med Phys (1990) 0.75

Dual surface coil with high-B1 homogeneity for deep organ MR imaging. Magn Reson Imaging (1997) 0.75

A parallel algorithm for rotating-frame zeugmatography. Magn Reson Med (1984) 0.75

Frequency shift artifacts in MR imaging. J Comput Assist Tomogr (1985) 0.75