Magnetic resonance velocity vector mapping of blood flow in thoracic aortic aneurysms and grafts.

PubWeight™: 1.17‹?› | Rank: Top 10%

🔗 View Article (PMID 7564437)

Published in J Thorac Cardiovasc Surg on September 01, 1995

Authors

H G Bogren1, R H Mohiaddin, G Z Yang, P J Kilner, D N Firmin

Author Affiliations

1: Royal Brompton Hospital, National Heart and Lung Institute, London, United Kingdom.

Articles by these authors

Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J (2001) 8.90

Asymmetric redirection of flow through the heart. Nature (2000) 2.99

Blood flow imaging by cine magnetic resonance. J Comput Assist Tomogr (1986) 2.05

Sites and sizes of fat deposits around the pharynx in obese patients with obstructive sleep apnoea and weight matched controls. Eur Respir J (1989) 2.04

Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping. Circulation (1993) 1.91

Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. J Comput Assist Tomogr (1984) 1.91

Repaired coarctation: a "cost-effective" approach to identify complications in adults. J Am Coll Cardiol (2000) 1.79

The aortic outflow and root: a tale of dynamism and crosstalk. Ann Thorac Surg (1999) 1.64

Age-related changes of human aortic flow wave velocity measured noninvasively by magnetic resonance imaging. J Appl Physiol (1985) (1993) 1.57

Images in cardiovascular medicine. Isolated noncompaction of the myocardium: a rarity or missed diagnosis? Circulation (2002) 1.48

Regional aortic compliance studied by magnetic resonance imaging: the effects of age, training, and coronary artery disease. Br Heart J (1989) 1.42

Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. J Comput Assist Tomogr (1985) 1.41

Magnetic resonance characterization of pulmonary arterial blood flow after single lung transplantation. J Thorac Cardiovasc Surg (1991) 1.38

Dimensional accuracy of magnetic resonance in studies of the heart. Lancet (1985) 1.37

Echo-planar magnetic resonance myocardial perfusion imaging: parametric map analysis and comparison with thallium SPECT. J Magn Reson Imaging (2001) 1.37

Magnetic resonance assessment of the pulmonary arterial trunk anatomy, flow, pulsatility and distensibility. Eur Heart J (1993) 1.25

MR navigator-echo monitoring of temporal changes in diaphragm position: implications for MR coronary angiography. J Magn Reson Imaging (1997) 1.24

Computational flow modeling of the left ventricle based on in vivo MRI data: initial experience. Ann Biomed Eng (2001) 1.23

Blurring the boundaries: scenario-based simulation in a clinical setting. Med Educ (2005) 1.22

Diagnosis in adolescents and adults with congenital heart disease. Prospective assessment of individual and combined roles of magnetic resonance imaging and transesophageal echocardiography. Circulation (1994) 1.19

Thin-section CT of the lungs: eye-tracking analysis of the visual approach to reading tiled and stacked display formats. Eur J Radiol (2006) 1.13

Blood flow patterns in the human aorta studied by magnetic resonance. Br Heart J (1987) 1.13

Real time blood flow imaging by spiral scan phase velocity mapping. Magn Reson Med (1994) 1.09

Magnetic resonance velocity mapping: clinical application of a new technique. Br Heart J (1987) 1.09

Magnetic resonance jet velocity mapping in mitral and aortic valve stenosis. Circulation (1993) 1.07

Pulmonary artery distensibility and blood flow patterns: a magnetic resonance study of normal subjects and of patients with pulmonary arterial hypertension. Am Heart J (1989) 1.06

The function of the aorta in ischemic heart disease: a magnetic resonance and angiographic study of aortic compliance and blood flow patterns. Am Heart J (1989) 1.06

Assessment of regional left ventricular function by magnetic resonance. Br Heart J (1986) 1.06

Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation. Phys Med Biol (2010) 1.06

A pervasive body sensor network for measuring postoperative recovery at home. Surg Innov (2007) 1.05

Phase ordering with automatic window selection (PAWS): a novel motion-resistant technique for 3D coronary imaging. Magn Reson Med (2000) 1.02

Magnetic resonance imaging of the pulmonary arteries and their systemic connections in pulmonary atresia: comparison with angiographic and surgical findings. Br Heart J (1987) 1.02

Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography. J Cardiovasc Magn Reson (1999) 1.02

Computation of flow pressure fields from magnetic resonance velocity mapping. Magn Reson Med (1996) 1.01

The application of phase shifts in NMR for flow measurement. Magn Reson Med (1990) 0.98

Dynamic range extension of cine velocity measurements using motion-registered spatiotemporal phase unwrapping. J Magn Reson Imaging (1996) 0.98

Multiresolution image registration for two-dimensional gel electrophoresis. Proteomics (2001) 0.97

Magnetic resonance volume flow and jet velocity mapping in aortic coarctation. J Am Coll Cardiol (1993) 0.96

Visualization of flow by vector analysis of multidirectional cine MR velocity mapping. J Comput Assist Tomogr (1994) 0.96

Blood flow patterns in the thoracic aorta studied with three-directional MR velocity mapping: the effects of age and coronary artery disease. J Magn Reson Imaging (1998) 0.95

Natural-orifice transluminal endoscopic surgery (NOTES) in Europe: summary of the working group reports of the Euro-NOTES meeting 2010. Endoscopy (2011) 0.95

Combined MR imaging and CFD simulation of flow in the human descending aorta. J Magn Reson Imaging (2001) 0.94

Vena caval flow: assessment with cine MR velocity mapping. Radiology (1990) 0.94

Coarctation of the aorta: MR imaging in late postoperative assessment. Radiology (1989) 0.93

Increased airway pressure and simulated branch pulmonary artery stenosis increase pulmonary regurgitation after repair of tetralogy of Fallot. Real-time analysis with a conductance catheter technique. Circulation (1997) 0.93

Vortical flow feature recognition: a topological study of in vivo flow patterns using MR velocity mapping. J Comput Assist Tomogr (1998) 0.93

Magnetic resonance velocity mapping of normal human transmitral velocity profiles. Heart Vessels (1995) 0.92

Magnetic resonance imaging of atherosclerotic vascular disease. Am J Hypertens (1993) 0.92

Automated monitoring of diaphragm end-expiratory position for real-time navigator echo MR coronary angiography. J Magn Reson Imaging (1999) 0.91

The influence of inflow boundary conditions on intra left ventricle flow predictions. J Biomech Eng (2003) 0.91

ERS transform for the automated detection of bronchial abnormalities on CT of the lungs. IEEE Trans Med Imaging (2001) 0.91

Valve and great vessel stenosis: assessment with MR jet velocity mapping. Radiology (1991) 0.90

Subject-specific computational simulation of left ventricular flow based on magnetic resonance imaging. Proc Inst Mech Eng H (2008) 0.89

Value of orientation training in laparoscopic cholecystectomy. Br J Surg (2011) 0.88

Incidence, location, pathology, and significance of pulmonary homograft stenosis after the Ross operation. Circulation (2001) 0.88

Left ventricular volume measured rapidly by oblique magnetic resonance imaging. Br Heart J (1988) 0.87

Magnetic resonance imaging: a method for the assessment of changes in vascular structure and function. J Hum Hypertens (1991) 0.87

Three-dimensional computed tomography bronchoscopy using clinical datasets: a comparison with fibreoptic bronchoscopy. Clin Radiol (1997) 0.87

The effect of dynamic vessel motion on haemodynamic parameters in the right coronary artery: a combined MR and CFD study. Br J Radiol (2009) 0.87

Magnetic resonance imaging of coronary arteries: technique and preliminary results. Br Heart J (1993) 0.87

Assessment of coronary artery stenosis by magnetic resonance imaging. Heart (1996) 0.87

Automatic tracking of the aorta in cardiovascular MR images using deformable models. IEEE Trans Med Imaging (1997) 0.87

Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging (1999) 0.86

Hybrid ordered phase encoding (HOPE): an improved approach for respiratory artifact reduction. J Magn Reson Imaging (1998) 0.86

Investigating intrinsic myocardial mechanics: the role of MR tagging, velocity phase mapping, and diffusion imaging. J Magn Reson Imaging (2000) 0.86

Measurement of regional aortic compliance by MR imaging: a study of reproducibility. J Magn Reson Imaging (1996) 0.85

Dual contrast TrueFISP imaging for left ventricular segmentation. Magn Reson Med (2001) 0.85

Regional myocardial velocity imaged by magnetic resonance in patients with ischaemic heart disease. Br Heart J (1994) 0.85

Images in cardiology: Saphenous vein graft aneurysm presenting as an anterior mediastinal mass. Heart (2002) 0.85

Assessment of regional left ventricular long-axis motion with MR velocity mapping in healthy subjects. J Magn Reson Imaging (1994) 0.85