A receiver operating characteristic partial area index for highly sensitive diagnostic tests.

PubWeight™: 3.69‹?› | Rank: Top 1%

🔗 View Article (PMID 8939225)

Published in Radiology on December 01, 1996

Authors

Y Jiang1, C E Metz, R M Nishikawa

Author Affiliations

1: Department of Radiology, Kurt Rossmann Laboratories for Radiologic Image Research, University of Chicago, IL 60637, USA.

Articles citing this

pROC: an open-source package for R and S+ to analyze and compare ROC curves. BMC Bioinformatics (2011) 16.75

Receiver operating characteristic (ROC) curve: practical review for radiologists. Korean J Radiol (2004) 2.69

Reliable and computationally efficient maximum-likelihood estimation of "proper" binormal ROC curves. Acad Radiol (2007) 1.91

Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM. Med Phys (2008) 1.86

A parametric ROC model-based approach for evaluating the predictiveness of continuous markers in case-control studies. Biometrics (2009) 1.79

Digital breast tomosynthesis is comparable to mammographic spot views for mass characterization. Radiology (2011) 1.31

Optimized approach to decision fusion of heterogeneous data for breast cancer diagnosis. Med Phys (2006) 1.18

Training neural network classifiers for medical decision making: the effects of imbalanced datasets on classification performance. Neural Netw (2007) 1.18

Effects of partial volume correction on discrimination between very early Alzheimer's dementia and controls using brain perfusion SPECT. Eur J Nucl Med Mol Imaging (2004) 1.11

On use of partial area under the ROC curve for evaluation of diagnostic performance. Stat Med (2013) 1.07

New developments in observer performance methodology in medical imaging. Semin Nucl Med (2011) 1.02

Malignant and benign breast masses on 3D US volumetric images: effect of computer-aided diagnosis on radiologist accuracy. Radiology (2007) 1.02

Quasi-continuous and discrete confidence rating scales for observer performance studies: Effects on ROC analysis. Acad Radiol (2007) 1.00

Computer-aided diagnosis of lung nodules on CT scans: ROC study of its effect on radiologists' performance. Acad Radiol (2010) 0.97

Exact confidence interval estimation for the difference in diagnostic accuracy with three ordinal diagnostic groups. J Stat Plan Inference (2010) 0.96

Accuracy of optical spectroscopy for the detection of cervical intraepithelial neoplasia without colposcopic tissue information; a step toward automation for low resource settings. J Biomed Opt (2012) 0.93

Multi-modality CADx: ROC study of the effect on radiologists' accuracy in characterizing breast masses on mammograms and 3D ultrasound images. Acad Radiol (2009) 0.91

In pursuit of a piece of the ROC. Radiology (1996) 0.90

Comparing areas under receiver operating characteristic curves: potential impact of the "Last" experimentally measured operating point. Radiology (2008) 0.88

Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling. Stat Biopharm Res (2012) 0.86

Prognostic classification of pediatric medulloblastoma based on chromosome 17p loss, expression of MYCC and MYCN, and Wnt pathway activation. Neuro Oncol (2011) 0.86

Evaluating the effect of image preprocessing on an information-theoretic CAD system in mammography. Acad Radiol (2008) 0.85

An analytic expression for the binormal partial area under the ROC curve. Acad Radiol (2012) 0.85

Evaluation of computer-aided detection and diagnosis systems. Med Phys (2013) 0.82

The average receiver operating characteristic curve in multireader multicase imaging studies. Br J Radiol (2014) 0.82

Automated regional registration and characterization of corresponding microcalcification clusters on temporal pairs of mammograms for interval change analysis. Med Phys (2008) 0.82

Jackknife variance of the partial area under the empirical receiver operating characteristic curve. Stat Methods Med Res (2014) 0.82

Satisfaction of Search in Chest Radiography 2015. Acad Radiol (2015) 0.81

Test-retest reliability in fMRI of language: group and task effects. Brain Lang (2006) 0.81

Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: results from independently conducted FROC∕ROC studies in mammography. Med Phys (2012) 0.80

Comparative statistical properties of expected utility and area under the ROC curve for laboratory studies of observer performance in screening mammography. Acad Radiol (2014) 0.79

The Impact of Fatigue on Satisfaction of Search in Chest Radiography. Acad Radiol (2017) 0.79

In vivo classification of breast masses using features derived from axial-strain and axial-shear images. Ultrason Imaging (2012) 0.76

AUC-Maximizing Ensembles through Metalearning. Int J Biostat (2016) 0.75

Subgroup specific incremental value of new markers for risk prediction. Lifetime Data Anal (2012) 0.75

Looking back at prospective studies. Acad Radiol (2008) 0.75

Estimating the Area Under ROC Curve When the Fitted Binormal Curves Demonstrate Improper Shape. Acad Radiol (2016) 0.75

Articles by these authors

Basic principles of ROC analysis. Semin Nucl Med (1978) 27.12

ROC methodology in radiologic imaging. Invest Radiol (1986) 7.55

Receiver operating characteristic rating analysis. Generalization to the population of readers and patients with the jackknife method. Invest Radiol (1992) 6.15

Variance-component modeling in the analysis of receiver operating characteristic index estimates. Acad Radiol (1997) 2.62

Effect of case selection on the performance of computer-aided detection schemes. Med Phys (1994) 2.35

Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: validation with computer simulation. Acad Radiol (1997) 2.06

Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise. Med Phys (2010) 2.06

Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images. Med Phys (1992) 2.01

Artificial neural networks in mammography: application to decision making in the diagnosis of breast cancer. Radiology (1993) 2.00

Malignant and benign clustered microcalcifications: automated feature analysis and classification. Radiology (1996) 1.92

Improvement in radiologists' detection of clustered microcalcifications on mammograms. The potential of computer-aided diagnosis. Invest Radiol (1990) 1.87

Improving breast cancer diagnosis with computer-aided diagnosis. Acad Radiol (1999) 1.73

Visual detection and localization of radiographic images. Radiology (1975) 1.60

Critical evaluation of stress testing in the diagnosis of peripheral vascular disease. Surgery (1982) 1.60

Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs. Radiology (1996) 1.52

Ideal observer approximation using Bayesian classification neural networks. IEEE Trans Med Imaging (2001) 1.51

Computerized mass detection for digital breast tomosynthesis directly from the projection images. Med Phys (2006) 1.46

The "proper" binormal model: parametric receiver operating characteristic curve estimation with degenerate data. Acad Radiol (1997) 1.45

Continuous versus categorical data for ROC analysis: some quantitative considerations. Acad Radiol (2001) 1.44

An evaluation of lesion detectability with cone-beam, fanbeam and parallel-beam collimation in SPECT by continuous ROC study. J Nucl Med (1994) 1.43

The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques. Invest Radiol (1992) 1.42

Proper receiver operating characteristic analysis: the bigamma model. Acad Radiol (1997) 1.41

The effect of x-ray spectra from molybdenum and tungsten target tubes on image quality in mammography. Radiology (1976) 1.40

Evaluation of receiver operating characteristic curve data in terms of information theory, with applications in radiography. Radiology (1973) 1.29

Data compression: effect on diagnostic accuracy in digital chest radiography. Radiology (1991) 1.27

Computer-aided diagnosis in radiology: potential and pitfalls. Eur J Radiol (1999) 1.26

Toward consensus on quantitative assessment of medical imaging systems. Med Phys (1995) 1.24

Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum. Med Phys (1985) 1.23

Density correction of peripheral breast tissue on digital mammograms. Radiographics (1996) 1.20

Potential of computer-aided diagnosis to reduce variability in radiologists' interpretations of mammograms depicting microcalcifications. Radiology (2001) 1.18

An improved computer-assisted diagnostic scheme using wavelet transform for detecting clustered microcalcifications in digital mammograms. Acad Radiol (1996) 1.17

The geometric transfer function component for scintillation camera collimators with straight parallel holes. Phys Med Biol (1980) 1.15

Quantitative effects of stationary linear image processing on noise and resolution of structure in radionuclide images. J Nucl Med (1974) 1.14

Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group. Radiology (2000) 1.14

Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance. Radiology (1986) 1.12

Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: a preliminary study. Med Phys (2008) 1.11

Comparison of receiver operating characteristic curves on the basis of optimal operating points. Acad Radiol (1996) 1.04

Components-of-variance models for random-effects ROC analysis: the case of unequal variance structures across modalities. Acad Radiol (2001) 1.04

Computer-aided detection and diagnosis of breast cancer. Radiol Clin North Am (2000) 1.04

Computerized classification of benign and malignant masses on digitized mammograms: a study of robustness. Acad Radiol (2000) 1.04

Determination of 3D imaging geometry and object configurations from two biplane views: an enhancement of the Metz-Fencil technique. Med Phys (1995) 1.03

Improved determination of biplane imaging geometry from two projection images and its application to three-dimensional reconstruction of coronary arterial trees. Med Phys (1997) 1.03

Evaluation of imaging properties of a laser film digitizer. Phys Med Biol (1992) 1.02

An improved shift-invariant artificial neural network for computerized detection of clustered microcalcifications in digital mammograms. Med Phys (1996) 1.02

Digital image processing: effect on detectability of simulated low-contrast radiographic patterns. Radiology (1984) 1.01

The effect of a thigh tourniquet on the incidence of deep venous thrombosis after operations on the fore part of the foot. J Bone Joint Surg Am (1982) 0.98

Effect of two rating formats in multi-disease ROC study of chest images. Invest Radiol (1990) 0.98

Computerized detection of pulmonary nodules in digital chest images: use of morphological filters in reducing false-positive detections. Med Phys (1990) 0.97

Investigation of basic imaging properties in digital radiography. 4. Effect of unsharp masking on the detectability of simple patterns. Med Phys (1985) 0.97

Computer-aided diagnosis of pulmonary nodules: results of a large-scale observer test. Radiology (1999) 0.96

Pulmonary nodules: computer-aided detection in digital chest images. Radiographics (1990) 0.95

Computer-aided diagnosis: development of automated schemes for quantitative analysis of radiographic images. Semin Ultrasound CT MR (1992) 0.95

Optimum detector spatial resolution for discriminating between tumour uptake distributions in scintigraphy. Phys Med Biol (1983) 0.95

Digital mammography. ROC studies of the effects of pixel size and unsharp-mask filtering on the detection of subtle microcalcifications. Invest Radiol (1987) 0.95

Analysis of noise properties of a class of exact methods of inverting the 2-D exponential radon transform [SPECT application]. IEEE Trans Med Imaging (1995) 0.95

Computerized detection of mass lesions in digital breast tomosynthesis images using two- and three dimensional radial gradient index segmentation. Technol Cancer Res Treat (2004) 0.94

A comparison of optimum detector spatial resolution in nuclear imaging based on statistical theory and on observer performance. Phys Med Biol (1978) 0.94

A genetic algorithm-based method for optimizing the performance of a computer-aided diagnosis scheme for detection of clustered microcalcifications in mammograms. Med Phys (1998) 0.93

A comparison of physical image quality indices and observer performance in the radiographic detection of nylon beads. Phys Med Biol (1984) 0.92

Computerized detection of clustered microcalcifications in digital mammograms using a shift-invariant artificial neural network. Med Phys (1994) 0.91

Effect of observer instruction on ROC study of chest images. Invest Radiol (1990) 0.91

Observer performance in detecting multiple radiographic signals. Prediction and analysis using a generalized ROC approach. Radiology (1976) 0.90

Computerized detection of clustered microcalcifications in digital mammograms: applications of artificial neural networks. Med Phys (1992) 0.89

Dependence of computer classification of clustered microcalcifications on the correct detection of microcalcifications. Med Phys (2001) 0.89

An "intelligent" workstation for computer-aided diagnosis. Radiographics (1993) 0.89

An evaluation of maximum likelihood-expectation maximization reconstruction for SPECT by ROC analysis. J Nucl Med (1992) 0.88

Signal-to-noise properties of mammographic film-screen systems. Med Phys (1985) 0.88

Investigation of basic imaging properties in digital radiography. 13. Effect of simple structured noise on the detectability of simulated stenotic lesions. Med Phys (1989) 0.87

Transfer function analysis of radiographic imaging systems. Phys Med Biol (1979) 0.86

On the orientation of mammographic structure. Med Phys (2011) 0.85

Maximum likelihood estimation of dose-response parameters for therapeutic operating characteristic (TOC) analysis of carcinoma of the nasopharynx. Int J Radiat Oncol Biol Phys (1982) 0.85

Automated detection of mass lesions in dedicated breast CT: a preliminary study. Med Phys (2012) 0.85

Image feature analysis and computer-aided diagnosis in mammography: reduction of false-positive clustered microcalcifications using local edge-gradient analysis. Med Phys (1995) 0.85

Digital chest radiography: effect on diagnostic accuracy of hard copy, conventional video, and reversed gray scale video display formats. Radiology (1988) 0.84

Automated segmentation of digitized mammograms. Acad Radiol (1995) 0.83

Quantitation of valvular insufficiency by computerized radionuclide angiography. Am J Cardiol (1974) 0.82

Results of a clinical receiver operating characteristic study comparing filtered backprojection and maximum likelihood estimator images in FDG PET studies. J Nucl Med (1993) 0.82

Comparison of eye position versus computer identified microcalcification clusters on mammograms. Med Phys (1997) 0.82

Comments on the generalization of receiver operating characteristic analysis to detection and localization tasks. Phys Med Biol (1977) 0.82

Magnetization transfer: a potential method to determine the age of multiple sclerosis lesions. AJNR Am J Neuroradiol (1994) 0.81

Digital radiography. A useful clinical tool for computer-aided diagnosis by quantitative analysis of radiographic images. Acta Radiol (1993) 0.81

Simulation studies of data classification by artificial neural networks: potential applications in medical imaging and decision making. J Digit Imaging (1993) 0.81

Wiener spectral effects of spatial correlation between the sites of characteristic x-ray emission and reabsorption in radiographic screen-film systems. Phys Med Biol (1983) 0.80

Optimization and FROC analysis of rule-based detection schemes using a multiobjective approach. IEEE Trans Med Imaging (1998) 0.80

Clinical use of digital mammography: the present and the prospects. J Digit Imaging (1995) 0.80

Effects of scatter substraction on detection and quantitation in hepatic SPECT. J Nucl Med (1999) 0.80

Detection of hepatic metastases: comparison of contrast-enhanced CT, unenhanced MR imaging, and iron oxide-enhanced MR imaging. AJR Am J Roentgenol (1990) 0.80

Scanning translucent glass-ceramic x-ray storage phosphors. Proc SPIE Int Soc Opt Eng (2010) 0.79

The magnetization transfer effect in cerebral infarction. AJNR Am J Neuroradiol (1994) 0.79

Effect of dominant features on neural network performance in the classification of mammographic lesions. Phys Med Biol (1999) 0.79

Constraints on the sensitivity and specificity of "logically" merged test results. J Nucl Med (1991) 0.79

Analysis of methods for reducing false positives in the automated detection of clustered microcalcifications in mammograms. Med Phys (1998) 0.79

Analysis of recorded image noise in nuclear medicine. Phys Med Biol (1981) 0.78

Development of a digital duplication system for portable chest radiographs. J Digit Imaging (1994) 0.78

Theoretical prediction of the geometric transfer function for focused collimators. J Nucl Med (1974) 0.77

Consensus diagnoses and "gold standards". Med Decis Making (1990) 0.77

Cost-effectiveness in radiology. Eur Radiol (2000) 0.76

Diagnostic performance of a receptor-binding radiopharmacokinetic model. J Nucl Med (1996) 0.75