Multireader, multimodality receiver operating characteristic curve studies: hypothesis testing and sample size estimation using an analysis of variance approach with dependent observations.

PubWeight™: 1.92‹?› | Rank: Top 3%

🔗 View Article (PMID 9419702)

Published in Acad Radiol on March 01, 1995

Authors

N A Obuchowski1

Author Affiliations

1: Cleveland Clinic Foundation, Department of Biostatistics, OH 44195-5196, USA.

Articles citing this

Recent developments in the Dorfman-Berbaum-Metz procedure for multireader ROC study analysis. Acad Radiol (2008) 2.18

A comparison of denominator degrees of freedom methods for multiple observer ROC analysis. Stat Med (2007) 2.13

Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol (2009) 1.83

Power estimation for multireader ROC methods an updated and unified approach. Acad Radiol (2011) 1.77

Prostate cancer: sextant localization at MR imaging and MR spectroscopic imaging before prostatectomy--results of ACRIN prospective multi-institutional clinicopathologic study. Radiology (2009) 1.48

Accuracy of soft-copy digital mammography versus that of screen-film mammography according to digital manufacturer: ACRIN DMIST retrospective multireader study. Radiology (2008) 1.10

New developments in observer performance methodology in medical imaging. Semin Nucl Med (2011) 1.02

Comparison between different cost devices for digital capture of X-ray films: an image characteristics detection approach. J Digit Imaging (2012) 0.99

Performance comparison of single-view digital breast tomosynthesis plus single-view digital mammography with two-view digital mammography. Eur Radiol (2012) 0.97

Prediction accuracy of a sample-size estimation method for ROC studies. Acad Radiol (2010) 0.95

Whole-body MR imaging for staging of malignant tumors in pediatric patients: results of the American College of Radiology Imaging Network 6660 Trial. Radiology (2012) 0.91

Comparison between differently priced devices for digital capture of X-ray films using computed tomography as a gold standard: a multireader-multicase receiver operating characteristic curve study. Telemed J E Health (2011) 0.91

Statistical approaches for modeling radiologists' interpretive performance. Acad Radiol (2009) 0.89

Impact of computer-aided detection systems on radiologist accuracy with digital mammography. AJR Am J Roentgenol (2014) 0.86

A marginal-mean ANOVA approach for analyzing multireader multicase radiological imaging data. Stat Med (2013) 0.86

Comparison of soft-copy and hard-copy reading for full-field digital mammography. Radiology (2009) 0.84

Evaluation of computer-aided detection and diagnosis systems. Med Phys (2013) 0.82

Accuracy and interpretation time of computer-aided detection among novice and experienced breast MRI readers. AJR Am J Roentgenol (2013) 0.82

Design and evaluation of a web-based interactive visualization system for lung transplant home monitoring data. AMIA Annu Symp Proc (2007) 0.82

Correlation of free-response and receiver-operating-characteristic area-under-the-curve estimates: results from independently conducted FROC∕ROC studies in mammography. Med Phys (2012) 0.80

Bounding Sample Size Projections for the Area Under a ROC Curve. J Stat Plan Inference (2009) 0.79

Sample size tables for computer-aided detection studies. AJR Am J Roentgenol (2011) 0.79

Perceived sufficiency of full-field digital mammograms with and without irreversible image data compression for comparison with next-year mammograms. J Digit Imaging (2011) 0.76

Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design. Biometrics (2014) 0.75

Utility of a Noninvasive 2-Gene Molecular Assay for Cutaneous Melanoma and Effect on the Decision to Biopsy. JAMA Dermatol (2017) 0.75