Published in Biomed Tech (Berl) on June 01, 1976
Sodium and potassium in oocytes of Triturus cristatus. J Cell Sci (1969) 1.11
[O2 sensitive L-lactate biosensors with enzyme membranes based on L-lactate-2-monooxygenase and L-lactate-oxidase with electroanalytic comparison]. Biomed Tech (Berl) (1996) 0.78
[Flow-optimized multianalytical system for haemoanalysis with ion-selective disc and coated glass electrodes (author's transl)]. J Clin Chem Clin Biochem (1981) 0.75
Effect of verapamil on ionized calcium excretion in human parotid saliva. Eur J Clin Pharmacol (1979) 0.75
[Ion-selective disc electrodes with neutral cation-carriers for automated electroanalysis of serum (author's transl)]. Biomed Tech (Berl) (1978) 0.75
[Monensin, an electrically charged carboxyl ionophor, and its neutral methylester as ion active components for Na+ selective disk electrodes]. Biomed Tech (Berl) (1987) 0.75
[Investigations on the performance of calcium selective disc-electrodes with electrically charged and neutral ligands in anaerobic serum measurements (author's transl)]. Res Exp Med (Berl) (1978) 0.75
[A NH(+4)-selective-enzymatic flow-through system. A method for the continuous enzymatic, electrochemical determination of urea, II (author's transl)]. J Clin Chem Clin Biochem (1978) 0.75
[Continuous intraoperative measurement of Na+, K+ and Ca++ with carrier membrane disc electrodes (author's transl)]. J Clin Chem Clin Biochem (1979) 0.75
[The influence of menstruation cycle on human parotid saliva composition (author's transl)]. Laryngol Rhinol Otol (Stuttg) (1979) 0.75
[Continuous measurement of cations in the blood-stream of patients (author's transl)]. Anaesthesist (1981) 0.75
[Method for the fabrication of carrier-PVC-membranes of ion selective disk electrodes and coated glass-electrodes using a pressure-controlled solvent evaporation technique (author's transl)]. Biomed Tech (Berl) (1980) 0.75
[Cation selective electroanalysis of K(+)-, Na(+)- and Ca2(+) concentrations in acetate dialysis solutions]. Biomed Tech (Berl) (1991) 0.75
[Ammonium-selective disc-electrode with the carrier-antibiotic nonactin. A method for the continuous enzymatic, electrochemical determination of urea, I (author's transl)]. J Clin Chem Clin Biochem (1978) 0.75
[Ionized calcium in the pancreatic juice of the dog: continuous registration with a disc electrode]. Biomed Tech (Berl) (1976) 0.75
[Calcium selective disk-electrodes for flow-measurements]. Biomed Tech (Berl) (1975) 0.75
Continuous and discontinuous ionography of the pancreatic juice and the parotid saliva using carrier-membrane disc-electrodes. Med Prog Technol (1980) 0.75
[Chloride selective disc electrode for flow-through measurements]. Biomed Tech (Berl) (1976) 0.75
[Multiple measurement system for the electrochemical analysis of flowing liquids and gases (author's transl)]. Biomed Tech (Berl) (1977) 0.75
[A new technique for continuous in vivo measurements with ionselective disc-electrodes: the course of K+- and Ca++-concentrations in the blood of alert rats after single injections (author's transl)]. Biomed Tech (Berl) (1978) 0.75
[Ionselective multi-disc-electrode (author's transl)]. Biomed Tech (Berl) (1977) 0.75
[A flow-through method for the O2-sensitive, enzymatic analysis of glucose (author's transl)]. J Clin Chem Clin Biochem (1977) 0.75
[Oxygen-sensitive-enzymatic measurement of ascorbic acid with a flow-through-method (author's transl)]. Biomed Tech (Berl) (1978) 0.75
[Disk-electrode]. Biomed Tech (Berl) (1975) 0.75
Transient response of the calcium homeostatic system of the conscious pig to bolus calcium injections. Am J Physiol (1982) 0.75
[Potassium-selective hemoanalysis using the valinomycin-disc-electrode (author's transl)]. Biomed Tech (Berl) (1979) 0.75
[Technology of electrochemical solid-contact catheter sensors and telescope catheter electrode systems for the measurement of Ca++, K+, Na+, Cl-, Urea, pH, O2 and CO2 (author's transl)]. Biomed Tech (Berl) (1981) 0.75
[Investigations in the streaming blood of the alert animal and man. III. Postprandial and therapeutically induced changes of electrolyte concentration and hematocrit in man during hemodialysis (author's transl)]. Res Exp Med (Berl) (1978) 0.75