Biologic effects of implant debris.

PubWeight™: 1.69‹?› | Rank: Top 3%

🔗 View Article (PMID 19583551)

Published in Bull NYU Hosp Jt Dis on January 01, 2009

Authors

Nadim J Hallab1, Joshua J Jacobs

Author Affiliations

1: Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA. nhallab@rush.edu

Articles citing this

The future of biologic coatings for orthopaedic implants. Biomaterials (2013) 1.53

Metal ions activate vascular endothelial cells and increase lymphocyte chemotaxis and binding. J Orthop Res (2013) 1.52

Voltage-gated proton channels: molecular biology, physiology, and pathophysiology of the H(V) family. Physiol Rev (2013) 1.35

The basic science of periprosthetic osteolysis. Instr Course Lect (2001) 1.18

Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms. Acta Biomater (2013) 1.15

Total knee arthroplasty in patients with hypersensitivity to metals. Int Orthop (2014) 1.00

In vivo assessment of the host reactions to the biodegradation of the two novel magnesium alloys ZEK100 and AX30 in an animal model. Biomed Eng Online (2012) 0.98

The basic science of periprosthetic osteolysis. Instr Course Lect (2013) 0.93

Contributions of human tissue analysis to understanding the mechanisms of loosening and osteolysis in total hip replacement. Acta Biomater (2014) 0.92

Metal hypersensitivity and metal ion levels in patients with coated or uncoated total knee arthroplasty: a randomised controlled study. Int Orthop (2013) 0.90

Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms. J Orthop Res (2013) 0.86

Enhanced growth and osteogenic differentiation of human osteoblast-like cells on boron-doped nanocrystalline diamond thin films. PLoS One (2011) 0.86

Anti-oxidation treatment of ultra high molecular weight polyethylene components to decrease periprosthetic osteolysis: evaluation of osteolytic and osteogenic properties of wear debris particles in a murine calvaria model. Curr Rheumatol Rep (2013) 0.84

Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J Biomed Mater Res A (2014) 0.83

Bone and the innate immune system. Curr Osteoporos Rep (2014) 0.83

The pathobiology and pathology of aseptic implant failure. Bone Joint Res (2016) 0.81

Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern. Biomed Res Int (2015) 0.80

Biomaterial hypersensitivity: is it real? Supportive evidence and approach considerations for metal allergic patients following total knee arthroplasty. Biomed Res Int (2015) 0.80

Polyethylene wear particles induce TLR 2 upregulation in the synovial layer of mice. J Mater Sci Mater Med (2013) 0.79

Painful knee arthroplasty: definition and overview. Clin Cases Miner Bone Metab (2011) 0.79

Macrophages increase microparticle uptake by enterocyte-like Caco-2 cell monolayers. J Anat (2010) 0.79

Macromolecular prodrug of dexamethasone prevents particle-induced peri-implant osteolysis with reduced systemic side effects. J Control Release (2013) 0.79

Treating orthopedic prosthesis with diamond-like carbon: minimizing debris in Ti6Al4V. J Mater Sci Mater Med (2014) 0.78

Wear particles and ions from cemented and uncemented titanium-based hip prostheses-a histological and chemical analysis of retrieval material. J Biomed Mater Res B Appl Biomater (2014) 0.78

Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty. BMC Musculoskelet Disord (2010) 0.78

Biological response to prosthetic debris. World J Orthop (2015) 0.78

Porous bioactive scaffolds: characterization and biological performance in a model of tibial bone defect in rats. J Mater Sci Mater Med (2015) 0.77

Gene Expression in Osteolysis: Review on the Identification of Altered Molecular Pathways in Preclinical and Clinical Studies. Int J Mol Sci (2017) 0.77

Wear Particles Impair Antimicrobial Activity Via Suppression of Reactive Oxygen Species Generation and ERK1/2 Phosphorylation in Activated Macrophages. Inflammation (2015) 0.77

The impact of orthopedic device associated with carbonated hydroxyapatite on the oxidative balance: experimental study of bone healing rabbit model. Eur J Orthop Surg Traumatol (2012) 0.77

Are there biological markers for wear or corrosion? A systematic review. Clin Orthop Relat Res (2014) 0.77

Early diagnosis of orthopedic implant failure using macromolecular imaging agents. Pharm Res (2014) 0.76

Implant debris particle size affects serum protein adsorption which may contribute to particle size-based bioreactivity differences. J Long Term Eff Med Implants (2014) 0.76

Ultrasound gel minimizes third body debris with partial hardware removal in joint arthroplasty. Arthroplast Today (2016) 0.75

Bearings in Hip Arthroplasty: Joint Registries vs Precision Medicine: Review Article. HSS J (2016) 0.75

Antioxidant impregnated ultra-high molecular weight polyethylene wear debris particles display increased bone remodeling and a superior osteogenic:osteolytic profile vs. conventional UHMWPE particles in a murine calvaria model. J Orthop Res (2015) 0.75

The effect of platform switching on the levels of metal ion release from different implant-abutment couples. Int J Oral Sci (2016) 0.75

Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma. Skeletal Radiol (2017) 0.75

The influence of calcitonin gene-related peptide on markers of bone metabolism in MG-63 osteoblast-like cells co-cultured with THP-1 macrophage-like cells under virtually osteolytic conditions. BMC Musculoskelet Disord (2016) 0.75

Presence of interleukin-17C in the tissue around aseptic loosened implants. Int Orthop (2013) 0.75

Histopathological Analysis of PEEK Wear Particle Effects on the Synovial Tissue of Patients. Biomed Res Int (2016) 0.75

The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res (2016) 0.75

Metal debris concentrations in soft tissues adjacent to loosened femoral stems is higher in uncemented than cemented implants. BMC Musculoskelet Disord (2014) 0.75

Titanium Implant Impairment and Surrounding Muscle Cell Death Following High-Salt Diet: An In Vivo Study. PLoS One (2016) 0.75

Cobalt Alloy Implant Debris Induces Inflammation and Bone Loss Primarily through Danger Signaling, Not TLR4 Activation: Implications for DAMP-ening Implant Related Inflammation. PLoS One (2016) 0.75

PMMA third-body wear after unicondylar knee arthroplasty decuples the UHMWPE wear particle generation in vitro. Biomed Res Int (2015) 0.75

Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses. Diagn Interv Radiol (2015) 0.75

Material Science in Cervical Total Disc Replacement. Biomed Res Int (2015) 0.75

Resveratrol Protects against Titanium Particle-Induced Aseptic Loosening Through Reduction of Oxidative Stress and Inactivation of NF-κB. Inflammation (2016) 0.75

The pathology of failed McKee-Farrar implants: correlation with modern metal-on-metal-implant failure. J Mater Sci Mater Med (2017) 0.75

Low-intensity pulsed ultrasound (LIPUS) prevents periprosthetic inflammatory loosening through FBXL2-TRAF6 ubiquitination pathway. Sci Rep (2017) 0.75

Adenovirus-mediated siRNA targeting TNF-α and overexpression of bone morphogenetic protein-2 promotes early osteoblast differentiation on a cell model of Ti particle-induced inflammatory response in vitro. Braz J Med Biol Res (2013) 0.75

Therapeutic effects of OP-1 on metal wear particle induced osteoblasts injury in vitro. Int J Clin Exp Med (2015) 0.75

alpha1-Acid glycoprotein production in rat dorsal air pouch in response to inflammatory stimuli, dexamethasone and honey bee venom. Exp Mol Pathol (2010) 0.75

Biocompatibility of Four Common Orthopedic Biomaterials Following a High-Salt Diet: An In Vivo Study. Int J Mol Sci (2017) 0.75

Strontium-Substituted Bioceramics Particles: A New Way to Modulate MCP-1 and Gro-α Production by Human Primary Osteoblastic Cells. Materials (Basel) (2016) 0.75

Articles by these authors

(truncated to the top 100)

Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am (2012) 2.86

A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res (2002) 2.78

Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res (2010) 2.48

Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up. J Bone Joint Surg Am (2005) 2.14

Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am (2013) 1.95

A multinational assessment of metal-on-metal bearings in hip replacement. J Bone Joint Surg Am (2011) 1.90

Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty. Clin Orthop Relat Res (2004) 1.86

Preoperative testing for sepsis before revision total knee arthroplasty. J Arthroplasty (2007) 1.83

Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials (2006) 1.77

Applications of porous tantalum in total hip arthroplasty. J Am Acad Orthop Surg (2006) 1.76

Modes of wear after semiconstrained total elbow arthroplasty. J Bone Joint Surg Am (2008) 1.71

Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am (2013) 1.60

Serum metal levels and bearing surfaces in total hip arthroplasty. J Arthroplasty (2006) 1.56

Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res (2009) 1.45

Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res (2005) 1.44

The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res (2004) 1.44

Professionalism in publishing. J Bone Joint Surg Am (2006) 1.43

Loosening and osteolysis associated with metal-on-metal bearings: A local effect of metal hypersensitivity? J Bone Joint Surg Am (2006) 1.43

Preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg (2011) 1.39

Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976) (2011) 1.35

Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up, at a minimum of twenty years, of previous reports. J Bone Joint Surg Am (2009) 1.34

Do Complication Rates Differ by Gender After Metal-on-metal Hip Resurfacing Arthroplasty? A Systematic Review. Clin Orthop Relat Res (2015) 1.31

Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res (2004) 1.31

Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty (2004) 1.29

Outpatient total knee arthroplasty with a minimally invasive technique. J Arthroplasty (2005) 1.26

Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res (2010) 1.23

American Academy of Orthopaedic Surgeons clinical practice guideline on: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Bone Joint Surg Am (2012) 1.23

Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty. J Orthop Surg Res (2008) 1.23

A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty (2004) 1.22

Spinal implant debris-induced osteolysis. Spine (Phila Pa 1976) (2003) 1.21

Mechanisms of failure of total hip replacements: lessons learned from retrieval studies. Clin Orthop Relat Res (2004) 1.18

Inhibition of the Wnt-β-catenin and Notch signaling pathways sensitizes osteosarcoma cells to chemotherapy. Biochem Biophys Res Commun (2013) 1.18

The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am (2005) 1.15

Cytokine-controlled RANKL and osteoprotegerin expression by human and mouse synovial fibroblasts: fibroblast-mediated pathologic bone resorption. Arthritis Rheum (2008) 1.15

AAOS clinical practice guideline: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg (2011) 1.13

Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty (2004) 1.10

The role of fibroblasts and fibroblast-derived factors in periprosthetic osteolysis. Arthritis Rheum (2006) 1.08

Extensor mechanism allograft reconstruction after total knee arthroplasty. A comparison of two techniques. J Bone Joint Surg Am (2004) 1.07

The evidence-based approach in bringing new orthopaedic devices to market. J Bone Joint Surg Am (2010) 1.06

Extensor mechanism allograft reconstruction after total knee arthroplasty. J Bone Joint Surg Am (2005) 1.05

Analysis of metal ion-induced DNA damage, apoptosis, and necrosis in human (Jurkat) T-cells demonstrates Ni2+ and V3+ are more toxic than other metals: Al3+, Be2+, Co2+, Cr3+, Cu2+, Fe3+, Mo5+, Nb5+, Zr2+. J Biomed Mater Res A (2008) 1.03

Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report. J Bone Joint Surg Am (2005) 1.02

In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater (2009) 1.01

Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts. J Biomed Mater Res (2002) 1.01

Clinical performance of contemporary tibial polyethylene components. J Arthroplasty (2006) 1.01

Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity. J Biomed Mater Res A (2010) 0.99

Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res (2015) 0.99

Serum and urine metal levels in patients with metal-on-metal surface arthroplasty. J Mater Sci Mater Med (2002) 0.98

Extended trochanteric osteotomy in complex primary total hip arthroplasty. A brief note. J Bone Joint Surg Am (2003) 0.98

Chemokine gene activation in human bone marrow-derived osteoblasts following exposure to particulate wear debris. J Biomed Mater Res A (2006) 0.97

Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis. J Orthop Surg Res (2006) 0.95

Biologic activity of wear particles. Instr Course Lect (2010) 0.94

Evaluation and treatment of painful total hip arthroplasties with modular metal taper junctions. Orthopedics (2012) 0.94

In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation. J Biomed Mater Res A (2010) 0.93

Surface damage in machined ram-extruded and net-shape molded retrieved polyethylene tibial inserts of total knee replacements. J Bone Joint Surg Am (2002) 0.93

Effects of soluble metals on human peri-implant cells. J Biomed Mater Res A (2005) 0.92

Titanium particles induce the immediate early stress responsive chemokines IL-8 and MCP-1 in osteoblasts. J Orthop Res (2002) 0.91

Coventry Award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem. Clin Orthop Relat Res (2002) 0.90

Chemokine IL-8 induction by particulate wear debris in osteoblasts is mediated by NF-kappaB. J Orthop Res (2005) 0.88

Shedding of the interleukin-6 (IL-6) receptor (gp80) determines the ability of IL-6 to induce gp130 phosphorylation in human osteoblasts. J Biol Chem (2002) 0.87

Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res (2012) 0.87

Evidence-based understanding of management perils for metal-on-metal hip arthroplasty patients. J Arthroplasty (2012) 0.86

In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater (2011) 0.86

Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms. J Orthop Res (2013) 0.86

The patella in revision total knee arthroplasty. J Bone Joint Surg Am (2003) 0.85

Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res (2014) 0.84

A technique for minimally invasive, quadriceps-sparing total knee arthroplasty. J Knee Surg (2006) 0.84

Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am (2012) 0.83

Porous tantalum in reconstructive surgery of the knee: a review. J Knee Surg (2007) 0.83

In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am (2011) 0.83

Technology assessment and adoption in orthopaedics: lessons learned. J Bone Joint Surg Am (2008) 0.83

The acetabular insert-metal backing interface: an additional source of polyethylene wear debris. J Arthroplasty (2005) 0.82

Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Joint Surg Am (2004) 0.82

Cruciate-retaining TKA using a third-generation system with a four-pegged tibial component: a minimum 10-year followup note. Clin Orthop Relat Res (2010) 0.82

Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res (2007) 0.81

Do ion concentrations after metal-on-metal hip resurfacing increase over time? A prospective study. J Arthroplasty (2012) 0.81

Tribology: a portal to understand joint failure? Arthritis Rheum (2007) 0.81

Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions? Clin Orthop Relat Res (2014) 0.80

Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res (2012) 0.80

Role of fibroblasts and fibroblast-derived growth factors in periprosthetic angiogenesis. J Orthop Res (2007) 0.80

Females with Unexplained Joint Pain Following Total Joint Arthroplasty Exhibit a Higher Rate and Severity of Hypersensitivity to Implant Metals Compared with Males: Implications of Sex-Based Bioreactivity Differences. J Bone Joint Surg Am (2017) 0.79

AOA symposium. Evidence-based medicine, the quality initiative, and P4P: performance or paperwork? J Bone Joint Surg Am (2008) 0.79

Effect of europium(II) stearate on the mechanical properties and the oxidation resistance of UHMWPE. J Mech Behav Biomed Mater (2010) 0.78

Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res (2012) 0.78

Hematologic genetic testing in high-risk patients before knee arthroplasty: a pilot study. Clin Orthop Relat Res (2011) 0.78

Interfacial kinetics of titanium- and cobalt-based implant alloys in human serum: metal release and biofilm formation. J Biomed Mater Res A (2003) 0.77

Implant design affects markers of bone resorption and formation in total hip replacement. J Bone Miner Res (2002) 0.77

Serum Metal Concentrations in Patients With Titanium Ceramic Composite Cervical Disc Replacements. Spine (Phila Pa 1976) (2017) 0.77

Intergranular pitting corrosion of CoCrMo biomedical implant alloy. J Biomed Mater Res B Appl Biomater (2013) 0.76

Metal Hypersensitivity and Total Knee Arthroplasty. J Am Acad Orthop Surg (2016) 0.76

Osteoarthritis of the hip. N Engl J Med (2008) 0.75

Role of technology assessment in orthopaedics. Clin Orthop Relat Res (2009) 0.75

A question of prevalence: liner dislodgment in Harris-Galante acetabular components. J Bone Joint Surg Am (2002) 0.75

The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res (2006) 0.75

Osteoarthritis of the knee. N Engl J Med (2006) 0.75

The biology of alternative bearing surfaces in total joint arthroplasty. Instr Course Lect (2005) 0.75

US bone and joint decade prepares for the future. Arthritis Rheum (2009) 0.75

Biomedical imaging archive network. Skeletal Radiol (2007) 0.75

Trends in joint arthroplasty: minimally invasive surgery, wear-resistant materials, and biologics. J Clin Rheumatol (2007) 0.75

Closing the gap: Orthopaedic research in clinical practice. J Am Acad Orthop Surg (2007) 0.75