Published in J Bone Joint Surg Am on May 15, 2013
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res (2015) 0.99
Implant based differences in adverse local tissue reaction in failed total hip arthroplasties: a morphological and immunohistochemical study. BMC Clin Pathol (2014) 0.96
The biological response to orthopaedic implants for joint replacement: Part I: Metals. J Biomed Mater Res B Appl Biomater (2016) 0.92
How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res (2014) 0.90
There Are No Differences in Short- to Mid-term Survivorship Among Total Hip-bearing Surface Options: A Network Meta-analysis. Clin Orthop Relat Res (2014) 0.89
The future role of metal-on-metal hip resurfacing. Int Orthop (2015) 0.87
Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging. Int Orthop (2014) 0.85
Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship Than Other Designs: A Nationwide Cohort of 324,108 Patients. Clin Orthop Relat Res (2017) 0.83
Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions? Clin Orthop Relat Res (2014) 0.80
Adverse reactions to metal debris occur with all types of hip replacement not just metal-on-metal hips: a retrospective observational study of 3340 revisions for adverse reactions to metal debris from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. BMC Musculoskelet Disord (2016) 0.78
Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases. BMC Clin Pathol (2016) 0.78
Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation. Int Orthop (2016) 0.77
Revision for taper corrosion at the neck-body junction following total hip arthroplasty: pearls and pitfalls. Curr Rev Musculoskelet Med (2016) 0.77
Trunnionosis: the latest culprit in adverse reactions to metal debris following hip arthroplasty. Skeletal Radiol (2014) 0.77
Local and Systemic Changes Associated with Long-term, Percutaneous, Static Implantation of Titanium Alloys in Rhesus Macaques (Macaca mulatta). Comp Med (2017) 0.75
Bone mineral density after implantation of a femoral neck hip prosthesis--a prospective 5 year follow-up. BMC Musculoskelet Disord (2015) 0.75
Titanium Implant Impairment and Surrounding Muscle Cell Death Following High-Salt Diet: An In Vivo Study. PLoS One (2016) 0.75
That's why we call it BIOmechanics!: commentary on an article by H. John Cooper, MD, et al.: "Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck". J Bone Joint Surg Am (2013) 0.75
Is there any difference in survivorship of total hip arthroplasty with different bearing surfaces? A systematic review and network meta-analysis. Int J Clin Exp Med (2015) 0.75
Joint replacement surgery and the innate immune system. J Long Term Eff Med Implants (2014) 0.75
Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study. J Arthroplasty (2016) 0.75
Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket. Clin Orthop Relat Res (2016) 0.75
A New Case of Fracture of a Modular Femoral Neck Device After a Total Hip Arthroplasty. Open Orthop J (2015) 0.75
The histological and elemental characterisation of corrosion particles from taper junctions. Bone Joint Res (2016) 0.75
Ultrasound findings in asymptomatic patients with modular metal on metal total hip arthroplasty. Skeletal Radiol (2017) 0.75
Outcomes following revision surgery performed for adverse reactions to metal debris in non-metal-on-metal hip arthroplasty patients: Analysis of 185 revisions from the National Joint Registry for England and Wales. Bone Joint Res (2017) 0.75
Biocompatibility of Four Common Orthopedic Biomaterials Following a High-Salt Diet: An In Vivo Study. Int J Mol Sci (2017) 0.75
Local Cellular Responses to Titanium Dioxide from Orthopedic Implants. Biores Open Access (2017) 0.75
Inflammatory pseudotumor after ceramic-on-ceramic total hip arthroplasty. Arthroplast Today (2017) 0.75
CORR Insights(®): Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship than Other Designs: A Nationwide Cohort of 324,108 Patients. Clin Orthop Relat Res (2017) 0.75
In-situ Generated Tribomaterial in Metal/Metal Contacts: current understanding and future implications for implants. Biotribology (Oxf) (2017) 0.75
Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am (1969) 22.45
Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br (2008) 5.48
Accelerating failure rate of the ASR total hip replacement. J Bone Joint Surg Br (2011) 3.47
Histological features of pseudotumor-like tissues from metal-on-metal hips. Clin Orthop Relat Res (2010) 3.28
Perioperative testing for joint infection in patients undergoing revision total hip arthroplasty. J Bone Joint Surg Am (2008) 3.25
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am (2012) 2.86
The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res (2009) 2.83
A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res (2002) 2.78
In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res (1993) 2.43
High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. J Bone Joint Surg Br (2011) 2.16
Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. Acta Orthop (2009) 2.04
Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems. Clin Orthop Relat Res (1991) 2.01
Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am (1998) 1.96
Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. J Bone Joint Surg Br (2012) 1.75
Tissue reaction to metal on metal total hip prostheses. Clin Orthop Relat Res (1996) 1.66
Fretting wear in a modular neck hip prosthesis. J Biomed Mater Res (1997) 1.62
Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplasty (2008) 1.58
Corrosion between the components of modular femoral hip prostheses. J Bone Joint Surg Br (1992) 1.58
In vitro corrosion testing of modular hip tapers. J Biomed Mater Res B Appl Biomater (2003) 1.57
Local and distant products from modularity. Clin Orthop Relat Res (1995) 1.52
Concerns with modularity in total hip arthroplasty. Clin Orthop Relat Res (1994) 1.46
Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J Bone Joint Surg Am (1994) 1.44
Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material. BMC Musculoskelet Disord (2010) 1.37
Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am (2010) 1.32
Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater (1995) 1.32
Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res (2004) 1.31
Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report. J Bone Joint Surg Am (1988) 1.28
Design-related fretting wear in modular neck hip prosthesis. J Biomed Mater Res (1996) 1.26
Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty. J Arthroplasty (2011) 1.26
An analysis of the head-neck taper interface in retrieved hip prostheses. Clin Orthop Relat Res (1994) 1.23
Total hip arthroplasty modular neck failure. J Arthroplasty (2010) 1.20
Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. J Bone Joint Surg Br (2009) 1.19
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty (2006) 1.17
Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop (2009) 1.15
Corrosion of modular hip prostheses. J Bone Joint Surg Br (1991) 1.14
Corrosion-induced fracture of a double-modular hip prosthesis: a case report. J Bone Joint Surg Am (2010) 1.14
The tradeoffs associated with modular hip prostheses. Clin Orthop Relat Res (1995) 1.14
Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis. J Bone Joint Surg Br (2011) 1.13
Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis. J Biomech (2011) 1.11
Proximal component modularity in THA--at what cost? An implant retrieval study. Clin Orthop Relat Res (2012) 1.10
Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop Relat Res (1994) 1.09
Corrosion and wear at the modular interface of uncemented femoral stems. J Bone Joint Surg Br (1994) 1.09
Pseudotumor in a well-fixed metal-on-polyethylene uncemented hip arthroplasty. J Arthroplasty (2011) 1.08
Investigations on the galvanic corrosion of multialloy total hip prostheses. J Biomed Mater Res (1981) 1.08
Fracture of the modular femoral neck component in total hip arthroplasty. J Arthroplasty (2011) 1.05
Early failure of a modular femoral neck total hip arthroplasty component: a case report. J Bone Joint Surg Am (2010) 1.04
Modular femoral neck fracture after primary total hip arthroplasty. J Arthroplasty (2012) 1.03
Failure of the modular neck in a total hip arthroplasty. J Arthroplasty (2009) 0.98
Evaluation and treatment of painful total hip arthroplasties with modular metal taper junctions. Orthopedics (2012) 0.94
A comparison of two implant systems in restoration of hip geometry in arthroplasty. Clin Orthop Relat Res (2011) 0.91
Micromotion measurements with hip center and modular neck length alterations. Clin Orthop Relat Res (1999) 0.89
Clinical results of a modular neck hip system: hitting the "bull's-eye" more accurately. Am J Orthop (Belle Mead NJ) (2010) 0.88
Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation. J Orthop Traumatol (2011) 0.86
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am (2012) 2.86
A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res (2002) 2.78
Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res (2010) 2.48
Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up. J Bone Joint Surg Am (2005) 2.14
Modular taper junction corrosion and failure: how to approach a recalled total hip arthroplasty implant. J Arthroplasty (2013) 2.13
A multinational assessment of metal-on-metal bearings in hip replacement. J Bone Joint Surg Am (2011) 1.90
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty. Clin Orthop Relat Res (2004) 1.86
Preoperative testing for sepsis before revision total knee arthroplasty. J Arthroplasty (2007) 1.83
A prospective, randomized study of preoperative autologous donation for hip replacement surgery. J Bone Joint Surg Am (2002) 1.83
Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials (2006) 1.77
Applications of porous tantalum in total hip arthroplasty. J Am Acad Orthop Surg (2006) 1.76
Metal-on-metal bearing surfaces. J Am Acad Orthop Surg (2009) 1.72
Modes of wear after semiconstrained total elbow arthroplasty. J Bone Joint Surg Am (2008) 1.71
Biologic effects of implant debris. Bull NYU Hosp Jt Dis (2009) 1.69
Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am (2013) 1.60
Serum metal levels and bearing surfaces in total hip arthroplasty. J Arthroplasty (2006) 1.56
Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res (2009) 1.45
Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res (2005) 1.44
The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res (2004) 1.44
Professionalism in publishing. J Bone Joint Surg Am (2006) 1.43
Loosening and osteolysis associated with metal-on-metal bearings: A local effect of metal hypersensitivity? J Bone Joint Surg Am (2006) 1.43
Preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg (2011) 1.39
Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty. J Bone Joint Surg Am (2002) 1.39
The role of flexion contracture on outcomes in primary total knee arthroplasty. J Arthroplasty (2007) 1.39
Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976) (2011) 1.35
Wear particles. J Bone Joint Surg Am (2006) 1.35
Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up, at a minimum of twenty years, of previous reports. J Bone Joint Surg Am (2009) 1.34
Do Complication Rates Differ by Gender After Metal-on-metal Hip Resurfacing Arthroplasty? A Systematic Review. Clin Orthop Relat Res (2015) 1.31
Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res (2004) 1.31
Which factors influence preservation of the osteonecrotic femoral head? Clin Orthop Relat Res (2012) 1.30
Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty (2004) 1.29
Outpatient total knee arthroplasty with a minimally invasive technique. J Arthroplasty (2005) 1.26
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res (2010) 1.23
American Academy of Orthopaedic Surgeons clinical practice guideline on: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Bone Joint Surg Am (2012) 1.23
Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty. J Orthop Surg Res (2008) 1.23
A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty (2004) 1.22
Spinal implant debris-induced osteolysis. Spine (Phila Pa 1976) (2003) 1.21
Early failure of unicompartmental knee arthroplasty leading to revision. J Arthroplasty (2008) 1.18
Mechanisms of failure of total hip replacements: lessons learned from retrieval studies. Clin Orthop Relat Res (2004) 1.18
Inhibition of the Wnt-β-catenin and Notch signaling pathways sensitizes osteosarcoma cells to chemotherapy. Biochem Biophys Res Commun (2013) 1.18
The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am (2005) 1.15
Cytokine-controlled RANKL and osteoprotegerin expression by human and mouse synovial fibroblasts: fibroblast-mediated pathologic bone resorption. Arthritis Rheum (2008) 1.15
AAOS clinical practice guideline: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg (2011) 1.13
Slower recovery after two-incision than mini-posterior-incision total hip arthroplasty. A randomized clinical trial. J Bone Joint Surg Am (2008) 1.13
Patients preferred a mini-posterior THA to a contralateral two-incision THA. Clin Orthop Relat Res (2006) 1.12
Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty (2004) 1.11
Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty (2005) 1.10
Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty (2004) 1.10
The role of fibroblasts and fibroblast-derived factors in periprosthetic osteolysis. Arthritis Rheum (2006) 1.08
Implant survivorship and complication rates after total knee arthroplasty with a third-generation cemented system: 5 to 8 years followup. Clin Orthop Relat Res (2005) 1.07
Extensor mechanism allograft reconstruction after total knee arthroplasty. A comparison of two techniques. J Bone Joint Surg Am (2004) 1.07
The evidence-based approach in bringing new orthopaedic devices to market. J Bone Joint Surg Am (2010) 1.06
Effect of hip hemiarthroplasty on articular cartilage and bone in a canine model. Clin Orthop Relat Res (2005) 1.05
Metal degradation products: a cause for concern in metal-metal bearings? Clin Orthop Relat Res (2003) 1.05
Extensor mechanism allograft reconstruction after total knee arthroplasty. J Bone Joint Surg Am (2005) 1.05
Analysis of metal ion-induced DNA damage, apoptosis, and necrosis in human (Jurkat) T-cells demonstrates Ni2+ and V3+ are more toxic than other metals: Al3+, Be2+, Co2+, Cr3+, Cu2+, Fe3+, Mo5+, Nb5+, Zr2+. J Biomed Mater Res A (2008) 1.03
Implantation of the femoral stem into a bed of titanium granules using vibration: a pilot study of a new method for prosthetic fixation in 5 patients followed for up to 15 years. Ups J Med Sci (2007) 1.02
Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report. J Bone Joint Surg Am (2005) 1.02
Monitoring pelvic osteolysis following total hip replacement surgery: an algorithm for surveillance. J Bone Joint Surg Am (2002) 1.02
In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater (2009) 1.01
Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts. J Biomed Mater Res (2002) 1.01
Clinical performance of contemporary tibial polyethylene components. J Arthroplasty (2006) 1.01
Twenty-year survivorship of cementless anatomic graduated component total knee arthroplasty. J Arthroplasty (2009) 1.00
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res (2015) 0.99
Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity. J Biomed Mater Res A (2010) 0.99
Serum and urine metal levels in patients with metal-on-metal surface arthroplasty. J Mater Sci Mater Med (2002) 0.98
Extended trochanteric osteotomy in complex primary total hip arthroplasty. A brief note. J Bone Joint Surg Am (2003) 0.98
Bone ingrowth through porous titanium granulate around a femoral stem: histological assessment in a six-month canine hemiarthroplasty model. Ups J Med Sci (2007) 0.97
Chemokine gene activation in human bone marrow-derived osteoblasts following exposure to particulate wear debris. J Biomed Mater Res A (2006) 0.97
Vertebroplasty comparing injectable calcium phosphate cement compared with polymethylmethacrylate in a unique canine vertebral body large defect model. Spine J (2007) 0.96
Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis. J Orthop Surg Res (2006) 0.95
Local and systemic levels of tobramycin delivered from calcium sulfate bone graft substitute pellets. Clin Orthop Relat Res (2005) 0.95
Effect of initiation chemistry on the fracture toughness, fatigue strength, and residual monomer content of a novel high-viscosity, two-solution acrylic bone cement. J Biomed Mater Res (2002) 0.94
Biologic activity of wear particles. Instr Course Lect (2010) 0.94
Evaluation and treatment of painful total hip arthroplasties with modular metal taper junctions. Orthopedics (2012) 0.94
Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study. Clin Biomech (Bristol, Avon) (2008) 0.94
Surface damage in machined ram-extruded and net-shape molded retrieved polyethylene tibial inserts of total knee replacements. J Bone Joint Surg Am (2002) 0.93
Slower recovery after two-incision than mini-posterior-incision total hip arthroplasty. Surgical technique. J Bone Joint Surg Am (2009) 0.93
In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation. J Biomed Mater Res A (2010) 0.93
Effects of soluble metals on human peri-implant cells. J Biomed Mater Res A (2005) 0.92
Anatomy of the extensor mechanism in reference to quadriceps-sparing TKA. Clin Orthop Relat Res (2006) 0.92
Titanium particles induce the immediate early stress responsive chemokines IL-8 and MCP-1 in osteoblasts. J Orthop Res (2002) 0.91
Coventry Award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem. Clin Orthop Relat Res (2002) 0.90
Minimally invasive total knee arthroplasty with an optimized subvastus approach. J Arthroplasty (2006) 0.90
Revision total knee arthroplasty: what the practicing orthopaedic surgeon needs to know. J Bone Joint Surg Am (2010) 0.89
Chemokine IL-8 induction by particulate wear debris in osteoblasts is mediated by NF-kappaB. J Orthop Res (2005) 0.88
Gross trunnion failure after primary total hip arthroplasty. J Arthroplasty (2014) 0.87
No benefit of the two-incision THA over mini-posterior THA: a pilot study of strength and gait. Clin Orthop Relat Res (2009) 0.87
Effects of implant material and plate design on tendon function and morphology. Clin Orthop Relat Res (2006) 0.87
Shedding of the interleukin-6 (IL-6) receptor (gp80) determines the ability of IL-6 to induce gp130 phosphorylation in human osteoblasts. J Biol Chem (2002) 0.87
Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res (2012) 0.87
Autopsy analysis thirty years after metal-on-metal total hip replacement. A case report. J Bone Joint Surg Am (2003) 0.86
Evidence-based understanding of management perils for metal-on-metal hip arthroplasty patients. J Arthroplasty (2012) 0.86