Published in Phys Med Biol on April 01, 2010
Prior image constrained compressed sensing: implementation and performance evaluation. Med Phys (2012) 1.30
Nonconvex prior image constrained compressed sensing (NCPICCS): theory and simulations on perfusion CT. Med Phys (2011) 1.13
Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction. Med Phys (2013) 1.06
4D micro-CT for cardiac and perfusion applications with view under sampling. Phys Med Biol (2011) 1.02
Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT. Med Phys (2012) 0.94
Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model. Med Phys (2012) 0.87
Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response. Eur Radiol (2011) 0.83
Accelerated barrier optimization compressed sensing (ABOCS) for CT reconstruction with improved convergence. Phys Med Biol (2014) 0.83
Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging. Med Phys (2012) 0.83
Iterative image reconstruction for sparse-view CT using normal-dose image induced total variation prior. PLoS One (2013) 0.80
Investigation of different sparsity transforms for the PICCS algorithm in small-animal respiratory gated CT. PLoS One (2015) 0.78
A Novel Prior- and Motion-Based Compressed Sensing Method for Small-Animal Respiratory Gated CT. PLoS One (2016) 0.75
Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations. Neurocomputing (2016) 0.75
Iterative reconstruction for CT perfusion with a prior-image induced hybrid nonlocal means regularization: Phantom studies. Med Phys (2016) 0.75
Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med (2007) 22.30
Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab (1983) 9.59
Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys (2008) 7.52
High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med (1996) 6.90
Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys Med Biol (2008) 6.85
Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab (1985) 5.99
Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT. Med Phys (2007) 4.64
Simultaneous algebraic reconstruction technique (SART): a superior implementation of the art algorithm. Ultrason Imaging (1984) 4.52
High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results. Magn Reson Med (1996) 3.63
Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med (2003) 3.44
Assessing tumor perfusion and treatment response in rectal cancer with multisection CT: initial observations. Radiology (2005) 3.01
Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms. Phys Med Biol (2009) 2.91
Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT. Am J Physiol (1998) 2.52
Micro-computed tomography-current status and developments. Annu Rev Biomed Eng (2004) 2.11
Fundamental image quality limits for microcomputed tomography in small animals. Med Phys (2003) 2.11
In vivo small-animal imaging using micro-CT and digital subtraction angiography. Phys Med Biol (2008) 1.97
A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source. Phys Med Biol (2009) 1.97
High temporal resolution and streak-free four-dimensional cone-beam computed tomography. Phys Med Biol (2008) 1.96
Advanced hepatocellular carcinoma: CT perfusion of liver and tumor tissue--initial experience. Radiology (2007) 1.87
Molecular imaging in small animals--roles for micro-CT. J Cell Biochem Suppl (2002) 1.75
Fluorescence molecular imaging of small animal tumor models. Curr Mol Med (2004) 1.62
[Micro-CT. Technology and application for assessing bone structure]. Radiologe (1999) 1.60
Functional CT for quantifying tumor perfusion in antiangiogenic therapy in a rat model. Radiology (2005) 1.55
A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys Med Biol (2003) 1.51
A quality assurance phantom for the performance evaluation of volumetric micro-CT systems. Phys Med Biol (2007) 1.50
Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT. Stroke (2001) 1.40
Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke. Eur J Radiol (1999) 1.36
Perfusion CT of the brain: diagnostic approach for early detection of ischemic stroke. Radiology (1998) 1.31
Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization. Magn Reson Med (2003) 1.30
Quantitative assessment of colorectal cancer tumor vascular parameters by using perfusion CT: influence of tumor region of interest. Radiology (2008) 1.29
CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke. Radiology (2002) 1.27
Difference in tracer delay-induced effect among deconvolution algorithms in CT perfusion analysis: quantitative evaluation with digital phantoms. Radiology (2009) 1.22
Correlation of early dynamic CT perfusion imaging with whole-brain MR diffusion and perfusion imaging in acute hemispheric stroke. AJNR Am J Neuroradiol (2003) 1.20
CT assessment of cerebral perfusion: experimental validation and initial clinical experience. Radiology (1999) 1.14
Commissioning of a novel microCT/RT system for small animal conformal radiotherapy. Phys Med Biol (2009) 1.12
Functional CT quantification of tumor perfusion after transhepatic arterial embolization in a rat model. Radiology (2005) 1.10
Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7 and 2 micron level. Technol Health Care (1998) 1.09
In vivo micro-CT imaging of rat brain glioma: a comparison with 3T MRI and histology. Neurosci Lett (2009) 1.02
Forensic microradiology: micro-computed tomography (Micro-CT) and analysis of patterned injuries inside of bone. J Forensic Sci (2003) 1.00
Respiratory phase-correlated micro-CT imaging of free-breathing rodents. Phys Med Biol (2009) 0.96
Preparation of on-axis cylindrical trabecular bone specimens using micro-CT imaging. J Biomech Eng (2004) 0.96
Pharmacokinetics, micro-SPECT/CT imaging and therapeutic efficacy of (188)Re-DXR-liposome in C26 colon carcinoma ascites mice model. Nucl Med Biol (2008) 0.95
Micro-CT imaging of structure-to-function relationship of bone microstructure and associated vascular involvement. Technol Health Care (1998) 0.94
Tomosynthesis via Total Variation Minimization Reconstruction and Prior Image Constrained Compressed Sensing (PICCS) on a C-arm System. Proc SPIE Int Soc Opt Eng (2008) 0.93
[CT perfusion imaging in acute ischemic cerebral infarct: comparison of cerebral perfusion maps and conventional CT findings]. Rofo (2000) 0.86
Receptor-binding, biodistribution, dosimetry, and micro-SPECT/CT imaging of 111In-[DTPA(1), Lys(3), Tyr(4)]-bombesin analog in human prostate tumor-bearing mice. Cancer Biother Radiopharm (2009) 0.83
Practical injection-rate CT perfusion imaging: deconvolution-derived hemodynamics in a case of stroke. Neuroradiology (2001) 0.83
[Cerebral perfusion CT: theoretical aspects, methodical implementation and clinical experience in the diagnosis of ischemic cerebral infarction]. Rofo (2000) 0.82
Intraarterial infusion chemotherapy for head and neck cancers: evaluation of tumor perfusion with intraarterial CT during carotid arteriography. Radiat Med (2004) 0.80
Micro-CT in drug delivery. Eur J Pharm Biopharm (2009) 0.80
CT perfusion of the liver during selective hepatic arteriography: pure arterial blood perfusion of liver tumor and parenchyma. Radiat Med (2004) 0.80
Stereolithographic models simulating trabecular bone and their characterization by thin-slice- and micro-CT. Eur Radiol (2001) 0.77
Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys (2008) 7.52
Hippocampal-sparing whole-brain radiotherapy: a "how-to" technique using helical tomotherapy and linear accelerator-based intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys (2010) 3.05
Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT. Radiology (2012) 3.01
Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms. Phys Med Biol (2009) 2.91
Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging. AJR Am J Roentgenol (2012) 2.13
High temporal resolution and streak-free four-dimensional cone-beam computed tomography. Phys Med Biol (2008) 1.96
Sex-based differences in the effect of intra-arterial treatment of stroke: analysis of the PROACT-2 study. Stroke (2006) 1.86
Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data. Phys Med Biol (2004) 1.80
Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol (2009) 1.77
Quantitative imaging of electron density and effective atomic number using phase contrast CT. Phys Med Biol (2010) 1.69
Benefits of 2 years of intense exercise on bone density, physical fitness, and blood lipids in early postmenopausal osteopenic women: results of the Erlangen Fitness Osteoporosis Prevention Study (EFOPS). Arch Intern Med (2004) 1.51
Streaking artifacts reduction in four-dimensional cone-beam computed tomography. Med Phys (2008) 1.47
Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography. J Am Coll Cardiol (2007) 1.44
Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol (2002) 1.41
Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction. Phys Med Biol (2009) 1.36
Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm. Radiology (2011) 1.34
Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT. Med Phys (2010) 1.33
Prior image constrained compressed sensing: implementation and performance evaluation. Med Phys (2012) 1.30
Time-resolved interventional cardiac C-arm cone-beam CT: an application of the PICCS algorithm. IEEE Trans Med Imaging (2011) 1.20
Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing. Phys Med Biol (2010) 1.17
Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose <0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction. Eur Radiol (2012) 1.17
Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies. Med Phys (2010) 1.12
Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction. Med Phys (2013) 1.06
Efficiency of antiscatter grids for flat-detector CT. Phys Med Biol (2007) 1.06
Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping. Med Phys (2012) 1.06
In vivo micro-CT imaging of rat brain glioma: a comparison with 3T MRI and histology. Neurosci Lett (2009) 1.02
Grating based x-ray differential phase contrast imaging without mechanical phase stepping. Opt Express (2014) 1.00
Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm. Phys Med Biol (2012) 0.97
Performance studies of four-dimensional cone beam computed tomography. Phys Med Biol (2011) 0.96
Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography. Med Phys (2011) 0.96
Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector. Phys Med Biol (2005) 0.96
Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study. Med Phys (2011) 0.94
Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT. Med Phys (2012) 0.94
A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography. Phys Med Biol (2007) 0.93
Tomosynthesis via Total Variation Minimization Reconstruction and Prior Image Constrained Compressed Sensing (PICCS) on a C-arm System. Proc SPIE Int Soc Opt Eng (2008) 0.93
Teaching NeuroImages: methotrexate leukoencephalopathy mimicking a transient ischemic attack. Neurology (2010) 0.90
Quantification of hepatic steatosis with dual-energy computed tomography: comparison with tissue reference standards and quantitative magnetic resonance imaging in the ob/ob mouse. Invest Radiol (2012) 0.87
Sub-milliSievert (sub-mSv) CT colonography: a prospective comparison of image quality and polyp conspicuity at reduced-dose versus standard-dose imaging. Eur Radiol (2015) 0.84
Spatial resolution characterization of differential phase contrast CT systems via modulation transfer function (MTF) measurements. Phys Med Biol (2013) 0.84
Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging. Med Phys (2012) 0.83
Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response. Eur Radiol (2011) 0.83
Current status and future perspectives of magnetic resonance high-field imaging: a summary. Neuroimaging Clin N Am (2012) 0.83
Correlation between human observer performance and model observer performance in differential phase contrast CT. Med Phys (2013) 0.83
Exercise effects on menopausal risk factors of early postmenopausal women: 3-yr Erlangen fitness osteoporosis prevention study results. Med Sci Sports Exerc (2005) 0.82
Dynamic contrast-enhanced micro-computed tomography correlates with 3-dimensional fluorescence ultramicroscopy in antiangiogenic therapy of breast cancer xenografts. Invest Radiol (2014) 0.82
Geometric accuracy in robot-assisted total hip replacement surgery. Comput Aided Surg (2003) 0.81
A shift-invariant filtered backprojection (FBP) cone-beam reconstruction algorithm for the source trajectory of two concentric circles using an equal weighting scheme. Phys Med Biol (2006) 0.81
Prospective evaluation of prior image constrained compressed sensing (PICCS) algorithm in abdominal CT: a comparison of reduced dose with standard dose imaging. Abdom Imaging (2015) 0.80
Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging. Phys Med Biol (2015) 0.79
Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT. Med Phys (2012) 0.79
Temporally targeted imaging method applied to ECG-gated computed tomography: preliminary phantom and in vivo experience. Acad Radiol (2008) 0.79
Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography. Phys Med Biol (2012) 0.78
Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy. Phys Med Biol (2011) 0.77
Interior tomography in x-ray differential phase contrast CT imaging. Phys Med Biol (2012) 0.77
A simple technique for interventional tool placement combining fluoroscopy with interventional computed tomography on a C-arm system. Neurosurgery (2010) 0.77
C-arm based cone-beam CT using a two-concentric-arc source trajectory: system evaluation. Proc SPIE Int Soc Opt Eng (2008) 0.77
Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory. Proc SPIE Int Soc Opt Eng (2008) 0.76
Spectral optimization for micro-CT. Med Phys (2012) 0.76
Time resolved contrast enhanced intracranial MRA using a single dose delivered as sequential injections and highly constrained projection reconstruction (HYPR CE). Magn Reson Med (2011) 0.76
An FBP image reconstruction algorithm for x-ray differential phase contrast CT. Proc SPIE Int Soc Opt Eng (2008) 0.75
HYPR TOF: time-resolved contrast-enhanced intracranial MR angiography using time-of-flight as the spatial constraint. J Magn Reson Imaging (2011) 0.75
Improving radiation dose efficiency of X-ray differential phase contrast imaging using an energy-resolving grating interferometer and a novel rank constraint. Opt Express (2016) 0.75
Overview and a Word of Thanks. Med Phys (2016) 0.75
Correction of data truncation artifacts in differential phase contrast (DPC) tomosynthesis imaging. Phys Med Biol (2015) 0.75
Demonstration of temperature imaging by H<sub>2</sub>O absorption spectroscopy using compressed sensing tomography. Appl Opt (2015) 0.75
[Worthiness of Sir Godfrey N. Hounsfield]. Z Med Phys (2004) 0.75
Radiation dose reduction in CT myocardial perfusion imaging using SMART-RECON. IEEE Trans Med Imaging (2017) 0.75
Time-delayed summation as a means of improving resolution on fast rotating computed tomography systems. Med Phys (2012) 0.75
Image quality of volume rendering of the bronchial tree: Kymogram-gated versus retrospectively ECG-gated and non-gated multi-row detector CT. Acad Radiol (2005) 0.75