Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

PubWeight™: 0.95‹?› | Rank: Top 15%

🔗 View Article (PMC 3368348)

Published in Invest Radiol on February 01, 2011

Authors

Nathan S Artz1, Andrew L Wentland, Elizabeth A Sadowski, Arjang Djamali, Thomas M Grist, Songwon Seo, Sean B Fain

Author Affiliations

1: Department of Medical Physics, Wisconsin Institute for Medical Research, University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705, USA.

Articles citing this

New magnetic resonance imaging methods in nephrology. Kidney Int (2013) 1.60

Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla. BMC Nephrol (2014) 0.88

Quantitative renal perfusion measurements in a rat model of acute kidney injury at 3T: testing inter- and intramethodical significance of ASL and DCE-MRI. PLoS One (2013) 0.87

Reproducibility of renal perfusion MR imaging in native and transplanted kidneys using non-contrast arterial spin labeling. J Magn Reson Imaging (2011) 0.86

MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function. Nephrol Dial Transplant (2011) 0.84

The pathophysiology of the chronic cardiorenal syndrome: a magnetic resonance imaging study. Eur Radiol (2015) 0.78

Dynamic contrast-enhanced magnetic resonance imaging measurement of renal function in patients undergoing partial nephrectomy: preliminary experience. Invest Radiol (2013) 0.77

Determination of split renal function using dynamic CT-angiography: preliminary results. PLoS One (2014) 0.77

Longitudinal Assessment of Renal Perfusion and Oxygenation in Transplant Donor-Recipient Pairs Using Arterial Spin Labeling and Blood Oxygen Level-Dependent Magnetic Resonance Imaging. Invest Radiol (2016) 0.75

Sensitivity of arterial spin labeling perfusion MRI to pharmacologically induced perfusion changes in rat kidneys. J Magn Reson Imaging (2014) 0.75

Functional MRI for characterization of renal perfusion impairment and edema formation due to acute kidney injury in different mouse strains. PLoS One (2017) 0.75

Articles cited by this

Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis. Radiology (2007) 2.79

Contrast-induced nephropathy. AJR Am J Roentgenol (2004) 2.60

Extension of borderzone myocardium in postinfarction dilated cardiomyopathy. J Am Coll Cardiol (2002) 2.52

Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function. Am J Physiol Renal Physiol (2001) 1.99

Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion. J Appl Physiol (1985) (1993) 1.69

FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med (2004) 1.63

Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: initial experience. Radiology (2006) 1.11

Renal perfusion in humans: MR imaging with spin tagging of arterial water. Radiology (1995) 1.08

Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE. Magn Reson Imaging (2000) 1.07

Measurement of kidney perfusion by magnetic resonance imaging: comparison of MRI with arterial spin labeling to para-aminohippuric acid plasma clearance in male subjects with metabolic syndrome. Nephrol Dial Transplant (2009) 1.07

Oxygen consumption and blood flow in the hypothermic, perfused kidney. Am J Physiol (1959) 1.07

Arterial spin labeling blood flow magnetic resonance imaging for the characterization of metastatic renal cell carcinoma(1). Acad Radiol (2005) 1.06

Blood oxygen level-dependent and perfusion magnetic resonance imaging: detecting differences in oxygen bioavailability and blood flow in transplanted kidneys. Magn Reson Imaging (2009) 1.06

Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labeling. Magn Reson Med (2009) 1.05

Effect of restricted water exchange on cerebral blood flow values calculated with arterial spin tagging: a theoretical investigation. Magn Reson Med (2000) 1.05

Renal disease: value of functional magnetic resonance imaging with flow and perfusion measurements. Invest Radiol (2004) 0.98

Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results. Eur Radiol (2009) 0.96

Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent. Invest Radiol (2009) 0.95

Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state--dependence on blood volume and water exchange. Magn Reson Med (2002) 0.94

Quantitative MR measures of intrarenal perfusion in the assessment of transplanted kidneys: initial experience. Acad Radiol (2009) 0.93

Functional magnetic resonance imaging of human renal allografts during the post-transplant period: preliminary observations. Magn Reson Imaging (1997) 0.92

High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media. Rofo (2005) 0.91

Perfusion quantitation in transplanted rat kidney by MRI with arterial spin labeling. Kidney Int (1998) 0.90

Influence of desflurane, isoflurane and halothane on regional tissue perfusion in dogs. Can J Anaesth (1992) 0.90

Magnetic resonance imaging for the evaluation of rejection of a kidney allograft in the rat. Transpl Int (1996) 0.84

The magnetic resonance renogram in renal transplant evaluation using dynamic contrast-enhanced MR imaging. Transplantation (1995) 0.84

Renal hemodynamic responses to intrarenal infusion of acetylcholine: comparison with effects of PGE2 and NO donor. Kidney Int (2006) 0.83

Systemic distribution of blood flow in ponies during 1.45%, 1.96%, and 2.39% end-tidal isoflurane-O2 anesthesia. Am J Vet Res (1987) 0.81

Morphologic and dynamic renal imaging with assessment of glomerular filtration rate in a pcy-mouse model using a clinical 3.0 Tesla scanner. Invest Radiol (2009) 0.81

Accuracy of blood flow values determined by arterial spin labeling: a validation study in isolated porcine kidneys. J Magn Reson Imaging (2007) 0.80

Effects of indomethacin on responses of regional kidney perfusion to vasoactive agents in rabbits. Clin Exp Pharmacol Physiol (2002) 0.80

Systemic and regional hemodynamics assessment in rats with fluorescent microspheres. J Cardiovasc Pharmacol (1999) 0.78

Articles by these authors

Nephrogenic systemic fibrosis: risk factors and incidence estimation. Radiology (2007) 4.25

Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med (2002) 3.57

PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography. AJNR Am J Neuroradiol (2005) 2.82

Early emphysematous changes in asymptomatic smokers: detection with 3He MR imaging. Radiology (2006) 2.35

Telomere length varies by DNA extraction method: implications for epidemiologic research. Cancer Epidemiol Biomarkers Prev (2013) 2.14

Serum β2-microglobulin at discharge predicts mortality and graft loss following kidney transplantation. Kidney Int (2013) 2.12

Transstenotic pressure gradients: measurement in swine--retrospectively ECG-gated 3D phase-contrast MR angiography versus endovascular pressure-sensing guidewires. Radiology (2007) 1.77

Severe asthma: lessons learned from the National Heart, Lung, and Blood Institute Severe Asthma Research Program. Am J Respir Crit Care Med (2011) 1.76

Functional lung imaging using hyperpolarized gas MRI. J Magn Reson Imaging (2007) 1.64

Least-squares chemical shift separation for (13)C metabolic imaging. J Magn Reson Imaging (2007) 1.59

Pulmonary 3He magnetic resonance imaging of childhood asthma. J Allergy Clin Immunol (2012) 1.52

Genotypes of NK cell KIR receptors, their ligands, and Fcγ receptors in the response of neuroblastoma patients to Hu14.18-IL2 immunotherapy. Cancer Res (2010) 1.51

Tubular expression of heat-shock protein 27 inhibits fibrogenesis in obstructive nephropathy. Kidney Int (2012) 1.50

C1q Binding Activity of De Novo Donor-specific HLA Antibodies in Renal Transplant Recipients With and Without Antibody-mediated Rejection. Transplantation (2015) 1.50

Low serum magnesium is associated with decreased graft survival in patients with chronic cyclosporin nephrotoxicity. Nephrol Dial Transplant (2005) 1.48

Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction. Magn Reson Med (2005) 1.46

Iterative projection reconstruction of time-resolved images using highly-constrained back-projection (HYPR). Magn Reson Med (2008) 1.43

Optimized 3D ultrashort echo time pulmonary MRI. Magn Reson Med (2012) 1.41

Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory. IEEE Trans Med Imaging (2006) 1.40

BOLD-MRI assessment of intrarenal oxygenation and oxidative stress in patients with chronic kidney allograft dysfunction. Am J Physiol Renal Physiol (2006) 1.36

Neural-cardiac coupling in threat-evoked anxiety. J Cogn Neurosci (2005) 1.33

Assessment of acute renal transplant rejection with blood oxygen level-dependent MR imaging: initial experience. Radiology (2005) 1.27

Aggressive surgical management of peritoneal carcinomatosis with low mortality in a high-volume tertiary cancer center. Ann Surg Oncol (2007) 1.21

Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels. Radiology (2002) 1.21

Arterial spin labeling MRI for assessment of perfusion in native and transplanted kidneys. Magn Reson Imaging (2010) 1.17

Detection of age-dependent changes in healthy adult lungs with diffusion-weighted 3He MRI. Acad Radiol (2005) 1.17

Epithelial-to-mesenchymal transition and chronic allograft tubulointerstitial fibrosis. Transplant Rev (Orlando) (2008) 1.15

3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition. Magn Reson Med (2008) 1.14

Heat shock protein 27 (HSP27): biomarker of disease and therapeutic target. Fibrogenesis Tissue Repair (2012) 1.13

Syndecan-1 in breast cancer stroma fibroblasts regulates extracellular matrix fiber organization and carcinoma cell motility. Am J Pathol (2010) 1.13

HSP27 is involved in the pathogenesis of kidney tubulointerstitial fibrosis. Am J Physiol Renal Physiol (2008) 1.11

Magnetic resonance angiography: current status and future directions. J Cardiovasc Magn Reson (2011) 1.10

Lung imaging in asthmatic patients: the picture is clearer. J Allergy Clin Immunol (2011) 1.10

Phase I trial of a novel anti-GD2 monoclonal antibody, Hu14.18K322A, designed to decrease toxicity in children with refractory or recurrent neuroblastoma. J Clin Oncol (2014) 1.09

Renal arteries: isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast. Radiology (2010) 1.08

Blood oxygen level-dependent and perfusion magnetic resonance imaging: detecting differences in oxygen bioavailability and blood flow in transplanted kidneys. Magn Reson Imaging (2009) 1.06

Imaging of lung ventilation and respiratory dynamics in a single ventilation cycle using hyperpolarized He-3 MRI. J Magn Reson Imaging (2007) 1.05

Correlation of chromosomal instability, telomere length and telomere maintenance in microsatellite stable rectal cancer: a molecular subclass of rectal cancer. PLoS One (2013) 1.05

Transfer of tolerance to collagen type V suppresses T-helper-cell-17 lymphocyte-mediated acute lung transplant rejection. Transplantation (2009) 1.04

Adult-onset calorie restriction delays the accumulation of mitochondrial enzyme abnormalities in aging rat kidney tubular epithelial cells. Am J Physiol Renal Physiol (2007) 1.03

Müllerian duct anomalies: embryological development, classification, and MRI assessment. J Magn Reson Imaging (2014) 1.02

Native kidney function following liver transplantation using calcineurin inhibitors: single-center analysis with 20 years of follow-up. Clin Transplant (2013) 1.02

Noninvasive assessment of transstenotic pressure gradients in porcine renal artery stenoses by using vastly undersampled phase-contrast MR angiography. Radiology (2011) 1.01

Reirradiation of large-volume recurrent glioma with pulsed reduced-dose-rate radiotherapy. Int J Radiat Oncol Biol Phys (2010) 1.00

Detection of acute renal ischemia in swine using blood oxygen level-dependent magnetic resonance imaging. J Magn Reson Imaging (2005) 0.98

Noninvasive assessment of early kidney allograft dysfunction by blood oxygen level-dependent magnetic resonance imaging. Transplantation (2006) 0.97

Bisphosphonates and bone fractures in long-term kidney transplant recipients. Transplantation (2008) 0.96

Three-dimensional imaging of ventilation dynamics in asthmatics using multiecho projection acquisition with constrained reconstruction. Magn Reson Med (2009) 0.95

MRI of pregnancy-related issues: müllerian duct anomalies. AJR Am J Roentgenol (2012) 0.95

Evaluation of uterine anomalies: 3D FRFSE cube versus standard 2D FRFSE. AJR Am J Roentgenol (2009) 0.93

Quantitative MR measures of intrarenal perfusion in the assessment of transplanted kidneys: initial experience. Acad Radiol (2009) 0.93

Effect of lanthanide ions on dynamic nuclear polarization enhancement and liquid-state T1 relaxation. Magn Reson Med (2012) 0.93

Aortic pulse wave velocity measurements with undersampled 4D flow-sensitive MRI: comparison with 2D and algorithm determination. J Magn Reson Imaging (2012) 0.93

Repeatability and internal consistency of abdominal 2D and 4D phase contrast MR flow measurements. Acad Radiol (2013) 0.93

Intratumoral hu14.18-IL-2 (IC) induces local and systemic antitumor effects that involve both activated T and NK cells as well as enhanced IC retention. J Immunol (2012) 0.91

Presurgical localization of the artery of Adamkiewicz with time-resolved 3.0-T MR angiography. Radiology (2010) 0.91

CKD stage-to-stage progression in native and transplant kidney disease. Nephrol Dial Transplant (2007) 0.90

Joint spatial-spectral reconstruction and k-t spirals for accelerated 2D spatial/1D spectral imaging of 13C dynamics. Magn Reson Med (2013) 0.90

Dynamic four-dimensional MR angiography of the chest and abdomen. Magn Reson Imaging Clin N Am (2009) 0.90

Measurement and comparison of T1 relaxation times in native and transplanted kidney cortex and medulla. J Magn Reson Imaging (2011) 0.89

Intronic locus determines SHROOM3 expression and potentiates renal allograft fibrosis. J Clin Invest (2014) 0.89

Floating table isotropic projection (FLIPR) acquisition: a time-resolved 3D method for extended field-of-view MRI during continuous table motion. Magn Reson Med (2004) 0.89

Effectiveness of MR angiography for the primary diagnosis of acute pulmonary embolism: clinical outcomes at 3 months and 1 year. J Magn Reson Imaging (2013) 0.88

Magnetic resonance imaging-monitored plasmid DNA delivery in primate limb muscle. Hum Gene Ther (2007) 0.88

Recurrent atypical hemolytic uremic syndrome associated with factor I mutation in a living related renal transplant recipient. Am J Kidney Dis (2008) 0.88

Drug insight: maintenance immunosuppression in kidney transplant recipients. Nat Clin Pract Nephrol (2006) 0.88

Fat/water separation in single acquisition steady-state free precession using multiple echo radial trajectories. Magn Reson Med (2005) 0.88

Helical tomotherapy setup variations in canine nasal tumor patients immobilized with a bite block. Vet Radiol Ultrasound (2012) 0.87

The effects of SNR on ADC measurements in diffusion-weighted hyperpolarized He-3 MRI. J Magn Reson (2006) 0.87

Survivors of endometrial cancer: who is at risk for sexual dysfunction? Gynecol Oncol (2011) 0.87

Luminex-based desensitization protocols: the University of Wisconsin initial experience. Transplantation (2011) 0.86

Reproducibility of renal perfusion MR imaging in native and transplanted kidneys using non-contrast arterial spin labeling. J Magn Reson Imaging (2011) 0.86