Published in IEEE Trans Neural Syst Rehabil Eng on March 19, 2013
Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding. J Assoc Res Otolaryngol (2014) 1.26
Clinical evaluation of an image-guided cochlear implant programming strategy. Audiol Neurootol (2014) 1.14
Automatic localization of cochlear implant electrodes in CT. Med Image Comput Comput Assist Interv (2014) 1.07
Automatic graph-based localization of cochlear implant electrodes in CT. Med Image Comput Comput Assist Interv (2015) 0.94
Comparisons between detection threshold and loudness perception for individual cochlear implant channels. Ear Hear (2014) 0.92
Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users. Ear Hear (2015) 0.92
Validation of a clinical assessment of spectral-ripple resolution for cochlear implant users. Ear Hear (2014) 0.91
Initial Results With Image-guided Cochlear Implant Programming in Children. Otol Neurotol (2016) 0.89
Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users. Ear Hear (2015) 0.86
Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds. J Assoc Res Otolaryngol (2016) 0.81
Validation of minimally invasive, image-guided cochlear implantation using Advanced Bionics, Cochlear, and Medel electrodes in a cadaver model. Int J Comput Assist Radiol Surg (2013) 0.81
Evaluation of Rigid Cochlear Models for Measuring Cochlear Implant Electrode Position. Otol Neurotol (2016) 0.80
Reducing Channel Interaction Through Cochlear Implant Programming May Improve Speech Perception: Current Focusing and Channel Deactivation. Trends Hear (2016) 0.79
Automatic segmentation of intra-cochlear anatomy in post-implantation CT of unilateral cochlear implant recipients. Med Image Anal (2014) 0.79
Results of Postoperative, CT-based, Electrode Deactivation on Hearing in Prelingually Deafened Adult Cochlear Implant Recipients. Otol Neurotol (2016) 0.78
Spectral and temporal analysis of simulated dead regions in cochlear implants. J Assoc Res Otolaryngol (2015) 0.77
An artifact-robust, shape library-based algorithm for automatic segmentation of inner ear anatomy in post-cochlear-implantation CT. Proc SPIE Int Soc Opt Eng (2014) 0.77
Automatic selection of the active electrode set for image-guided cochlear implant programming. J Med Imaging (Bellingham) (2016) 0.75
Automatic localization of landmark sets in head CT images with regression forests for image registration initialization. Proc SPIE Int Soc Opt Eng (2016) 0.75
Relationship Between Electrode-to-Modiolus Distance and Current Levels for Adults With Cochlear Implants. Otol Neurotol (2016) 0.75
Vowel and consonant confusions from spectrally manipulated stimuli designed to simulate poor cochlear implant electrode-neuron interfaces. J Acoust Soc Am (2016) 0.75
Effects of electrode deactivation on speech recognition in multichannel cochlear implant recipients. Cochlear Implants Int (2017) 0.75
The Electrically Evoked Compound Action Potential: From Laboratory to Clinic. Front Neurosci (2017) 0.75
Morphometric analysis of white matter lesions in MR images: method and validation. IEEE Trans Med Imaging (1994) 7.94
Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants. J Acoust Soc Am (2001) 5.75
Better speech recognition with cochlear implants. Nature (1991) 5.55
Revised CNC lists for auditory tests. J Speech Hear Disord (1962) 4.35
The abbreviated profile of hearing aid benefit. Ear Hear (1995) 3.77
Speech-discrimination scores modeled as a binomial variable. J Speech Hear Res (1978) 3.24
The BKB (Bamford-Kowal-Bench) sentence lists for partially-hearing children. Br J Audiol (1979) 3.17
Noise susceptibility of cochlear implant users: the role of spectral resolution and smearing. J Assoc Res Otolaryngol (2005) 2.71
The resolution of complex spectral patterns by cochlear implant and normal-hearing listeners. J Acoust Soc Am (2003) 2.17
Frequency map for the human cochlear spiral ganglion: implications for cochlear implants. J Assoc Res Otolaryngol (2007) 2.15
Development and validation of the AzBio sentence lists. Ear Hear (2011) 2.13
Speech recognition materials and ceiling effects: considerations for cochlear implant programs. Audiol Neurootol (2008) 2.13
Across-site patterns of modulation detection: relation to speech recognition. J Acoust Soc Am (2012) 1.92
Electrode discrimination and speech recognition in postlingually deafened adult cochlear implant subjects. J Acoust Soc Am (1997) 1.84
Cochlear implants: current designs and future possibilities. J Rehabil Res Dev (2008) 1.74
Automatic segmentation of intracochlear anatomy in conventional CT. IEEE Trans Biomed Eng (2011) 1.65
Spectral modulation detection and vowel and consonant identifications in cochlear implant listeners. J Acoust Soc Am (2009) 1.44
Automatic Identification of Cochlear Implant Electrode Arrays for Post-Operative Assessment. Proc SPIE Int Soc Opt Eng (2015) 1.31
How cochlear implants encode speech. Curr Opin Otolaryngol Head Neck Surg (2004) 1.29
Sensitivity of psychophysical measures to signal processor modifications in cochlear implant users. Hear Res (2010) 1.26
Electrical field interactions in different cochlear implant systems. J Acoust Soc Am (2003) 1.23
Statistical shape model segmentation and frequency mapping of cochlear implant stimulation targets in CT. Med Image Comput Comput Assist Interv (2012) 1.07
Speech understanding in noise with a Med-El COMBI 40+ cochlear implant using reduced channel sets. Ear Hear (2002) 0.91
Previous experience as a confounding factor in comparing cochlear-implant processing schemes. J Speech Hear Res (1986) 0.87
The adaptive bases algorithm for intensity-based nonrigid image registration. IEEE Trans Med Imaging (2003) 6.12
Comparison and evaluation of methods for liver segmentation from CT datasets. IEEE Trans Med Imaging (2009) 3.03
Automatic segmentation of the facial nerve and chorda tympani in CT images using spatially dependent feature values. Med Phys (2008) 2.48
Automatic identification and 3D rendering of temporal bone anatomy. Otol Neurotol (2009) 2.46
Clinical validation of percutaneous cochlear implant surgery: initial report. Laryngoscope (2008) 2.39
Horizontal-plane localization of noise and speech signals by postlingually deafened adults fitted with bilateral cochlear implants. Ear Hear (2007) 2.31
Computer-aided placement of deep brain stimulators: from planning to intraoperative guidance. IEEE Trans Med Imaging (2005) 1.99
Clinical validation study of percutaneous cochlear access using patient-customized microstereotactic frames. Otol Neurotol (2010) 1.97
Percutaneous cochlear access using bone-mounted, customized drill guides: demonstration of concept in vitro. Otol Neurotol (2007) 1.95
An atlas-based method to compensate for brain shift: preliminary results. Med Image Anal (2007) 1.91
A method to track cortical surface deformations using a laser range scanner. IEEE Trans Med Imaging (2005) 1.75
Multicenter U.S. bilateral MED-EL cochlear implantation study: speech perception over the first year of use. Ear Hear (2008) 1.70
Intratympanic dexamethasone for sudden sensorineural hearing loss after failure of systemic therapy. Laryngoscope (2007) 1.69
Interaural time and level difference thresholds for acoustically presented signals in post-lingually deafened adults fitted with bilateral cochlear implants using CIS+ processing. Ear Hear (2008) 1.67
Automatic segmentation of intracochlear anatomy in conventional CT. IEEE Trans Biomed Eng (2011) 1.65
Three-dimensional visualization of protein expression in mouse brain structures using imaging mass spectrometry. J Am Soc Mass Spectrom (2005) 1.62
Accuracy evaluation of microTargeting Platforms for deep-brain stimulation using virtual targets. IEEE Trans Biomed Eng (2009) 1.59
Integrating spatially resolved three-dimensional MALDI IMS with in vivo magnetic resonance imaging. Nat Methods (2007) 1.58
Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking. Med Phys (2003) 1.52
Concepts and preliminary data toward the realization of image-guided liver surgery. J Gastrointest Surg (2007) 1.50
Robust surface registration using salient anatomical features for image-guided liver surgery: algorithm and validation. Med Phys (2008) 1.49
Exostoses of the external auditory canal in white-water kayakers. Laryngoscope (2010) 1.43
Percutaneous cochlear implant drilling via customized frames: an in vitro study. Otolaryngol Head Neck Surg (2010) 1.43
Liver segmentation in living liver transplant donors: comparison of semiautomatic and manual methods. Radiology (2004) 1.39
An atlas-navigated optimal medial axis and deformable model algorithm (NOMAD) for the segmentation of the optic nerves and chiasm in MR and CT images. Med Image Anal (2011) 1.39
Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes. Laryngoscope (2014) 1.38
Anatomic verification of a novel method for precise intrascalar localization of cochlear implant electrodes in adult temporal bones using clinically available computed tomography. Laryngoscope (2010) 1.37
Implications of minimizing trauma during conventional cochlear implantation. Otol Neurotol (2011) 1.37
Automatic determination of optimal linear drilling trajectories for cochlear access accounting for drill-positioning error. Int J Med Robot (2010) 1.37
Assessment of electrode placement and audiological outcomes in bilateral cochlear implantation. Otol Neurotol (2011) 1.36
Design of a bone-attached parallel robot for percutaneous cochlear implantation. IEEE Trans Biomed Eng (2011) 1.24
CranialVault and its CRAVE tools: a clinical computer assistance system for deep brain stimulation (DBS) therapy. Med Image Anal (2010) 1.24
A nonrigid registration algorithm for longitudinal breast MR images and the analysis of breast tumor response. Magn Reson Imaging (2009) 1.23
Effect of brain shift on the creation of functional atlases for deep brain stimulation surgery. Int J Comput Assist Radiol Surg (2009) 1.22
Intraoperative brain shift compensation: accounting for dural septa. IEEE Trans Biomed Eng (2010) 1.21
Cortical Shift Tracking Using a Laser Range Scanner and Deformable Registration Methods. Med Image Comput Comput Assist Interv (2003) 1.21
Force measurement of insertion of cochlear implant electrode arrays in vitro: comparison of surgeon to automated insertion tool. Acta Otolaryngol (2010) 1.18
Automatic nonrigid registration of whole body CT mice images. Med Phys (2008) 1.18
Model-updated image-guided liver surgery: preliminary results using surface characterization. Prog Biophys Mol Biol (2010) 1.18
Semiautomatic registration of pre- and postbrain tumor resection laser range data: method and validation. IEEE Trans Biomed Eng (2008) 1.18
Speech recognition for unilateral and bilateral cochlear implant modes in the presence of uncorrelated noise sources. Ear Hear (2006) 1.17
Correction of motion artifact in cardiac optical mapping using image registration. IEEE Trans Biomed Eng (2005) 1.16
Longitudinal brain metabolic characterization of chronic alcoholics with proton magnetic resonance spectroscopy. Alcohol Clin Exp Res (2002) 1.16
Characterizing changes in MR images with color-coded Jacobians. Magn Reson Imaging (2004) 1.15
A fast and efficient method to compensate for brain shift for tumor resection therapies measured between preoperative and postoperative tomograms. IEEE Trans Biomed Eng (2010) 1.15
Clinical evaluation of an image-guided cochlear implant programming strategy. Audiol Neurootol (2014) 1.14
Accuracy of image-guided surgical systems at the lateral skull base as clinically assessed using bone-anchored hearing aid posts as surgical targets. Otol Neurotol (2008) 1.13
Automatic segmentation of the facial nerve and chorda tympani in pediatric CT scans. Med Phys (2011) 1.08
Statistical shape model segmentation and frequency mapping of cochlear implant stimulation targets in CT. Med Image Comput Comput Assist Interv (2012) 1.07
Automatic localization of cochlear implant electrodes in CT. Med Image Comput Comput Assist Interv (2014) 1.07
Tracking of vessels in intra-operative microscope video sequences for cortical displacement estimation. IEEE Trans Biomed Eng (2011) 1.06
Clinical accuracy of a customized stereotactic platform for deep brain stimulation after accounting for brain shift. Stereotact Funct Neurosurg (2010) 1.06
Validation of a fully automatic method for the routine selection of the anterior and posterior commissures in magnetic resonance images. Stereotact Funct Neurosurg (2009) 1.04
Intersurgeon variability in the selection of anterior and posterior commissures and its potential effects on target localization. Stereotact Funct Neurosurg (2008) 1.03
Robotic mastoidectomy. Otol Neurotol (2011) 1.03
Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation. Laryngoscope (2014) 1.03
Automatic selection of DBS target points using multiple electrophysiological atlases. Med Image Comput Comput Assist Interv (2005) 1.02
Quality of life in hearing-impaired adults: the role of cochlear implants and hearing aids. Otolaryngol Head Neck Surg (2004) 1.01
Percutaneous access to the petrous apex in vitro using customized micro-stereotactic frames based on image-guided surgical technology. Acta Otolaryngol (2009) 1.00
Outcome of cochlear implantation in pediatric auditory neuropathy. Otol Neurotol (2002) 1.00
Force of cochlear implant electrode insertion performed by a robotic insertion tool: comparison of traditional versus Advance Off-Stylet techniques. Otol Neurotol (2010) 0.99
Computer-generated fMRI phantoms with motion-distortion interaction. Magn Reson Imaging (2007) 0.99
Comparison of cochlear implant relevant anatomy in children versus adults. Otol Neurotol (2012) 0.98
Cochlear implant fixation using polypropylene mesh and titanium screws. Laryngoscope (2004) 0.98
Fluorescent retrograde axonal tracing of the facial nerve. Laryngoscope (2006) 0.97
Comparison of Middle Ear Visualization With Endoscopy and Microscopy. Otol Neurotol (2016) 0.96
Time of cochlear implant surgery in academic settings. Otolaryngol Head Neck Surg (2010) 0.96
Chemical meningitis following cerebellopontine angle tumor surgery. Otolaryngol Head Neck Surg (2008) 0.95
Evaluation of portable CT scanners for otologic image-guided surgery. Int J Comput Assist Radiol Surg (2011) 0.95
Customized, miniature rapid-prototype stereotactic frames for use in deep brain stimulator surgery: initial clinical methodology and experience from 263 patients from 2002 to 2008. Stereotact Funct Neurosurg (2010) 0.94
Estimation of intra-operative brain shift using a tracked laser range scanner. Conf Proc IEEE Eng Med Biol Soc (2007) 0.94
Validation of an algorithm for the nonrigid registration of longitudinal breast MR images using realistic phantoms. Med Phys (2010) 0.93
Design of a Tool Integrating Force Sensing With Automated Insertion in Cochlear Implantation. IEEE ASME Trans Mechatron (2011) 0.93
Registration of medical images using an interpolated closest point transform: method and validation. Med Image Anal (2004) 0.92
Automatic localization of the anterior commissure, posterior commissure, and midsagittal plane in MRI scans using regression forests. IEEE J Biomed Health Inform (2015) 0.92