Electrode discrimination and speech recognition in postlingually deafened adult cochlear implant subjects.

PubWeight™: 1.84‹?› | Rank: Top 3%

🔗 View Article (PMID 9407659)

Published in J Acoust Soc Am on December 01, 1997

Authors

T A Zwolan1, L M Collins, G H Wakefield

Author Affiliations

1: Department of Otolaryngology, University of Michigan, Ann Arbor 48109-0312, USA.

Associated clinical trials:

Comparing Site-selection Strategies | NCT03870217

Articles citing this

Music perception with cochlear implants: a review. Trends Amplif (2004) 2.76

Cochlear implants: a remarkable past and a brilliant future. Hear Res (2008) 2.51

Across-site patterns of modulation detection: relation to speech recognition. J Acoust Soc Am (2012) 1.92

Image-guidance enables new methods for customizing cochlear implant stimulation strategies. IEEE Trans Neural Syst Rehabil Eng (2013) 1.50

Speech recognition and temporal amplitude modulation processing by Mandarin-speaking cochlear implant users. Ear Hear (2008) 1.44

Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users. J Acoust Soc Am (2011) 1.35

Psychoacoustic abilities associated with music perception in cochlear implant users. Ear Hear (2010) 1.29

Cochlear implant electrode configuration effects on activation threshold and tonotopic selectivity. Hear Res (2007) 1.28

Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding. J Assoc Res Otolaryngol (2014) 1.26

Across-site threshold variation in cochlear implants: relation to speech recognition. Audiol Neurootol (2004) 1.24

Improving speech perception in noise with current focusing in cochlear implant users. Hear Res (2013) 1.23

Psychophysical versus physiological spatial forward masking and the relation to speech perception in cochlear implants. Ear Hear (2008) 1.20

Clinical evaluation of an image-guided cochlear implant programming strategy. Audiol Neurootol (2014) 1.14

Probing the electrode-neuron interface with focused cochlear implant stimulation. Trends Amplif (2010) 1.13

Relationship between channel interaction and spectral-ripple discrimination in cochlear implant users. J Acoust Soc Am (2013) 1.13

A model of incomplete adaptation to a severely shifted frequency-to-electrode mapping by cochlear implant users. J Assoc Res Otolaryngol (2009) 1.11

Psychophysically based site selection coupled with dichotic stimulation improves speech recognition in noise with bilateral cochlear implants. J Acoust Soc Am (2012) 0.99

Cochlear infrastructure for electrical hearing. Hear Res (2011) 0.97

A relation between electrode discrimination and amplitude modulation detection by cochlear implant listeners. J Acoust Soc Am (2010) 0.97

Improving virtual channel discrimination in a multi-channel context. Hear Res (2012) 0.97

Current-level discrimination and spectral profile analysis in multi-channel electrical stimulation. J Acoust Soc Am (2008) 0.97

Using temporal modulation sensitivity to select stimulation sites for processor MAPs in cochlear implant listeners. Audiol Neurootol (2013) 0.92

Initial Results With Image-guided Cochlear Implant Programming in Children. Otol Neurotol (2016) 0.89

Spatial selectivity to intracochlear electrical stimulation in the inferior colliculus is degraded after long-term deafness in cats. J Neurophysiol (2007) 0.88

Psychophysical metrics and speech recognition in cochlear implant users. Audiol Neurootol (2005) 0.88

Multichannel place pitch sensitivity in cochlear implant recipients. J Assoc Res Otolaryngol (2004) 0.88

Spatial tuning curves from apical, middle, and basal electrodes in cochlear implant users. J Acoust Soc Am (2011) 0.87

Relationship between multipulse integration and speech recognition with cochlear implants. J Acoust Soc Am (2014) 0.86

Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users. Ear Hear (2015) 0.86

Importance of cochlear health for implant function. Hear Res (2014) 0.85

Effects of site-specific level adjustments on speech recognition with cochlear implants. Ear Hear (2013) 0.84

Psychophysical assessment of stimulation sites in auditory prosthesis electrode arrays. Hear Res (2007) 0.84

Pitch adaptation patterns in bimodal cochlear implant users: over time and after experience. Ear Hear (2015) 0.84

Pitch ranking, electrode discrimination, and physiological spread-of-excitation using Cochlear's dual-electrode mode. J Acoust Soc Am (2014) 0.82

Effects of electrode configuration on cochlear implant modulation detection thresholds. J Acoust Soc Am (2011) 0.82

Psychoacoustic and phoneme identification measures in cochlear-implant and normal-hearing listeners. Trends Amplif (2013) 0.82

Using speech sounds to test functional spectral resolution in listeners with cochlear implants. J Acoust Soc Am (2015) 0.79

Consonant recognition as a function of the number of stimulation channels in the Hybrid short-electrode cochlear implant. J Acoust Soc Am (2012) 0.78

Frequency and electrode discrimination in children with cochlear implants. Hear Res (2010) 0.78

Pitch Discrimination: An Independent Factor in Cochlear Implant Performance Outcomes. Otol Neurotol (2015) 0.77

Pitch ranking, electrode discrimination, and physiological spread of excitation using current steering in cochlear implants. J Acoust Soc Am (2014) 0.76

Band importance functions of listeners with cochlear implants using clinical maps. J Acoust Soc Am (2016) 0.75

Vowel and consonant confusions from spectrally manipulated stimuli designed to simulate poor cochlear implant electrode-neuron interfaces. J Acoust Soc Am (2016) 0.75

The Electrically Evoked Compound Action Potential: From Laboratory to Clinic. Front Neurosci (2017) 0.75

Effects of electrode deactivation on speech recognition in multichannel cochlear implant recipients. Cochlear Implants Int (2017) 0.75

Articles by these authors

Temporal integration and multiple looks. J Acoust Soc Am (1991) 2.37

Health behavior of elderly Hispanic women: does cultural assimilation make a difference? Am J Public Health (1987) 2.23

Latent transition analysis for longitudinal data. Addiction (1996) 2.10

Developmental pathways to alcohol abuse and dependence in young adulthood. J Stud Alcohol (2000) 2.02

Attrition in prevention research. J Behav Med (1985) 1.96

Customizing treatment to the patient: adaptive treatment strategies. Drug Alcohol Depend (2007) 1.63

Simplified mechanical ventilation for hyaline-membrane disease. Lancet (1973) 1.56

Modeling transitions in latent stage-sequential processes: a substance use prevention example. J Consult Clin Psychol (1991) 1.47

Mechanical ventilation in newborn infants with respiratory railure. Lancet (1968) 1.45

Comparison of electrode discrimination, pitch ranking, and pitch scaling data in postlingually deafened adult cochlear implant subjects. J Acoust Soc Am (1997) 1.34

Frequency and adequacy of breast cancer screening among elderly Hispanic women. Prev Med (1987) 1.25

Investigation of the effects of temporal and spatial interactions on speech-recognition skills in cochlear-implant subjects. J Acoust Soc Am (1999) 1.22

The surface area of the adult human mouth and thickness of the salivary film covering the teeth and oral mucosa. J Dent Res (1987) 1.08

Clinical assessment of apnoea-alarm mattress for newborn infants. Lancet (1970) 1.07

Effects of stimulus level on electrode-place discrimination in human subjects with cochlear implants. Hear Res (1999) 1.05

High-school smoking prevention: results of a three-year longitudinal study. J Behav Med (1986) 0.96

Seven ways to increase power without increasing N. NIDA Res Monogr (1994) 0.95

Self-initiated smoking cessation among high school students. Addict Behav (1985) 0.95

Temporal pattern discrimination and speech recognition under electrical stimulation. J Acoust Soc Am (1994) 0.92

Cocaine binding sites in fetal rat brain: implications for prenatal cocaine action. Psychopharmacology (Berl) (1993) 0.92

An Alternative Framework for Defining Mediation. Multivariate Behav Res (1998) 0.92

Portable ventilator-incubator. Lancet (1970) 0.90

The acquisition and maintenance of safer sexual behaviors among injection drug users. Subst Use Misuse (1996) 0.88

Goodness-of-Fit Testing for Latent Class Models. Multivariate Behav Res (1993) 0.86

Monoamine transporters and the neurobehavioral teratology of cocaine. Pharmacol Biochem Behav (1996) 0.83

Increasing BCI communication rates with dynamic stopping towards more practical use: an ALS study. J Neural Eng (2015) 0.82

Characterization and localization of [125I]RTI-55-labeled cocaine binding sites in fetal and adult rat brain. J Pharmacol Exp Ther (1996) 0.80

The spectral shaping of neural discharges by refractory effects. J Acoust Soc Am (1993) 0.78

Temporal interactions between pure tones and amplitude-modulated noise. J Acoust Soc Am (1985) 0.78

Selective adaptation to linear frequency-modulated sweeps: evidence for direction-specific FM channels? J Acoust Soc Am (1984) 0.78

Using computational auditory models to predict simultaneous masking data: model comparison. IEEE Trans Biomed Eng (1999) 0.78

Omega: A General Formulation of the Rand Index of Cluster Recovery Suitable for Non-disjoint Solutions. Multivariate Behav Res (1988) 0.78

A comparison of two loudness balancing tasks in cochlear implant subjects using bipolar stimulation. Ear Hear (2001) 0.77

Extension of a temporal model of frequency discrimination: intensity effects in normal and hearing-impaired listeners. J Acoust Soc Am (1985) 0.77

Crossvalidation of Latent Class Models of Early Substance Use Onset. Multivariate Behav Res (1994) 0.76

Analysis of the performance of a model-based optimal auditory signal processor. J Acoust Soc Am (1998) 0.76

PONV in outpatients: when should it be assessed? Postoperative nausea and vomiting. Can J Anaesth (1999) 0.75

Deep venous thrombosis. Nurse Pract Forum (1998) 0.75

Applying dynamic data collection to improve dry electrode system performance for a P300-based brain-computer interface. J Neural Eng (2016) 0.75

Using the detectability index to predict P300 speller performance. J Neural Eng (2016) 0.75

Patterns of Crime in a Birth Cohort. Multivariate Behav Res (1983) 0.75

Modal distribution analysis, synthesis, and perception of a soprano's sung vowels. J Voice (2001) 0.75

An efficient method for detecting connectivity in neural ensembles. J Neurosci Methods (1993) 0.75

Patient disconnect. Can J Anaesth (1998) 0.75

Factor Recovery in Binary Data Sets: A Simulation. Multivariate Behav Res (1986) 0.75

The Charlottetown Click--or should it be the Carolina Maneuver? Can J Anaesth (1999) 0.75