Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring.

PubWeight™: 0.75‹?›

🔗 View Article (PMID 27535643)

Published in Diabetes Metab J on July 26, 2016

Authors

Satoshi Ugi1, Hiroshi Maegawa2, Katsutaro Morino2, Yoshihiko Nishio3, Toshiyuki Sato4, Seiki Okada4, Yasuo Kikkawa4, Toshihiro Watanabe4, Hiromu Nakajima5, Atsunori Kashiwagi6

Author Affiliations

1: Department of Medicine, Shiga University of Medical Science, Otsu, Japan. sugi@belle.shiga-med.ac.jp.
2: Department of Medicine, Shiga University of Medical Science, Otsu, Japan.
3: Department of Diabetes and Endocrine Medicine, Kagoshima University Graduate School of Medical and Dental Science, Kagoshima, Japan.
4: Central Research Laboratories, Sysmex Corporation, Kobe, Japan.
5: Department of Clinical Laboratory, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka, Japan.
6: Department of Medicine, Kusatsu General Hospital, Kusatsu, Japan.

Articles cited by this

The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. N Engl J Med (1993) 102.56

Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin-dependent diabetes mellitus: a randomized prospective 6-year study. Diabetes Res Clin Pract (1995) 12.51

Voglibose for prevention of type 2 diabetes mellitus: a randomised, double-blind trial in Japanese individuals with impaired glucose tolerance. Lancet (2009) 3.67

Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites. Diabetes Care (2002) 1.56

Acarbose slows progression of intima-media thickness of the carotid arteries in subjects with impaired glucose tolerance. Stroke (2004) 1.30

A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes. Diabetes Technol Ther (2012) 0.92

Evaluation of a minimally invasive system for measuring glucose area under the curve during oral glucose tolerance tests: usefulness of sweat monitoring for precise measurement. J Diabetes Sci Technol (2013) 0.90

Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling. Diabetes Technol Ther (2011) 0.87

Accuracy of a novel noninvasive transdermal continuous glucose monitor in critically ill patients. J Diabetes Sci Technol (2014) 0.84

Evaluation of the effect of polymeric microneedle arrays of varying geometries in combination with a high-velocity applicator on skin permeability and irritation. Biomed Microdevices (2014) 0.82

Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients. J Diabetes Investig (2013) 0.81

Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system. J Healthc Eng (2013) 0.80