National Cholesterol Education Program recommendations for triglyceride measurement: executive summary. The National Cholesterol Education Program Working Group on Lipoprotein Measurement.

PubWeight™: 1.51‹?› | Rank: Top 4%

🔗 View Article (PMID 7586511)

Published in Clin Chem on October 01, 1995

Authors

E A Stein1, G L Myers

Author Affiliations

1: Medical Research Laboratory, Highland Heights, KY 41076, USA.

Articles citing this

Lipid profiling identifies a triacylglycerol signature of insulin resistance and improves diabetes prediction in humans. J Clin Invest (2011) 3.23

Diabetes in relation to serum levels of polychlorinated biphenyls and chlorinated pesticides in adult Native Americans. Environ Health Perspect (2007) 1.56

High serum PCBs are associated with elevation of serum lipids and cardiovascular disease in a Native American population. Environ Res (2007) 1.46

Reduced circulating oxidized LDL is associated with hypocholesterolemia and enhanced thiol status in Gilbert syndrome. Free Radic Biol Med (2012) 1.06

Lower serum testosterone associated with elevated polychlorinated biphenyl concentrations in Native American men. Environ Health Perspect (2009) 1.03

Reference intervals for serum total cholesterol, HDL-cholesterol, LDL-cholesterol, triglycerides, Lp (a), apolipoprotein A-I, A-II, B, C-II, C-III, and E in healthy South Indians from Andhra Pradesh. Indian J Clin Biochem (2009) 0.93

High fiber probiotic fermented mare's milk reduces the toxic effects of mercury in rats. N Am J Med Sci (2010) 0.80

Protective effect of Trigonella foenum-graecum Linn. on monosodium glutamate-induced dyslipidemia and oxidative stress in rats. Indian J Pharmacol (2013) 0.80

Effects of Nigerian Piliostigma thonningii Species Leaf Extract on Lipid Profile in Wistar Rats. ISRN Pharmacol (2012) 0.79

Nutritional repletion of children with severe acute malnutrition does not affect VLDL apolipoprotein B-100 synthesis rate. J Nutr (2012) 0.78

Hypolipidemic effect of methanol fraction of Aconitum heterophyllum wall ex Royle and the mechanism of action in diet-induced obese rats. J Adv Pharm Technol Res (2012) 0.78

Human serum preβ1-high density lipoprotein levels are independently and negatively associated with coronary artery diseases. Nutr Metab (Lond) (2016) 0.77

Compromised Wound Healing in Ischemic Type 2 Diabetic Rats. PLoS One (2016) 0.76

A cost-benefit analysis of lipid standardization in the United States. Prev Chronic Dis (2011) 0.75

Chapter 1: Assessment of lipid status in adults with CKD. Kidney Int Suppl (2011) (2013) 0.75

Implementation of recommendations from the NCEP working group on lipoprotein measurement. Clin Chem (1996) 0.75

ACP Broad Sheet no 151: September 1997. Investigation of dyslipidaemias. J Clin Pathol (1997) 0.75

Sapium ellipticum (Hochst.) Pax Ethanol Leaf Extract Maintains Lipid Homeostasis in Streptozotocin-Induced Diabetic Rats. Int Sch Res Notices (2017) 0.75

Assessment of the Validity and Reproducibility of a Novel Standardized Test Meal for the Study of Postprandial Triacylglycerol Concentrations. Lipids (2017) 0.75

Articles by these authors

The national glycohemoglobin standardization program: a five-year progress report. Clin Chem (2001) 4.24

Blood lipid measurements. Variations and practical utility. JAMA (1992) 2.40

Current activities at the Centers for Disease Control and Prevention's National Diabetes Laboratory. Diabetes Technol Ther (1999) 1.95

Heterogeneity of HIV-1 and HIV-2. AIDS (1995) 1.41

Mutational inversion of control of the lactose operon of Escherichia coli. J Mol Biol (1971) 1.18

Biological variability in concentrations of serum lipids: sources of variation among results from published studies and composite predicted values. Clin Chem (1993) 1.09

Estimating the long-term effects of storage at -70 degrees C on cholesterol, triglyceride, and HDL-cholesterol measurements in stored sera. Clin Chem (2000) 1.01

The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods. Arch Pathol Lab Med (1998) 0.90

Matrix effects and the accuracy of cholesterol analysis. Arch Pathol Lab Med (1993) 0.89

Standardization of lipid, lipoprotein, and apolipoprotein measurements. Clin Chem (1988) 0.88

High-performance liquid chromatography method to analyze free and total urinary pyridinoline and deoxypyridinoline. Anal Biochem (2003) 0.83

Matrix effects on proficiency testing materials. Impact on accuracy of cholesterol measurement in laboratories in the nation's largest hospital system. Arch Pathol Lab Med (1993) 0.82

Reference system for cholesterol measurements. Scand J Clin Lab Invest Suppl (1990) 0.81

Estimating and minimizing effects of biologic sources of variation by relative range when measuring the mean of serum lipids and lipoproteins. Clin Chem (1994) 0.81

Comparison study of urinary pyridinoline and deoxypyridinoline measurements in 13 US laboratories. Clin Chem (2001) 0.79

Assessment of current National Cholesterol Education Program guidelines for total cholesterol triglyceride, HDL-cholesterol, and LDL-cholesterol measurements. Clin Chem (1998) 0.79

Establishment of reference methods for lipids, lipoproteins and apolipoproteins. Eur J Clin Chem Clin Biochem (1991) 0.78

Adequacy of NCEP recommendations for total cholesterol, triglycerides, HDLC, and LDLC measurements. Clin Chem (1998) 0.75

Calculating eGFR using the MDRD equation. QJM (2007) 0.75

A laboratory for handling chemical toxicants safely. Am Ind Hyg Assoc J (1987) 0.75

A comparison of results for cholesterol in human serum obtained by the Reference Method and by the Definitive Method of the National Reference System for cholesterol. Clin Chem (1990) 0.75

Assay instrument-dependent matrix effects in standardization of cholesterol measurements. Clin Chem (1993) 0.75

Point: status of lipid and lipoprotein standardization. Clin Chem (1997) 0.75

Clinical issues in cholesterol testing. J Med Assoc Ga (1991) 0.75

Implications of point-of-care testing for hemoglobin A1c. Diabetes Technol Ther (2000) 0.75

[The ways of harmonization of clinical laboratory measurement techniques]. Klin Lab Diagn (2013) 0.75

Factors influencing the accuracy of the national reference system total cholesterol reference method. Clin Chem (1991) 0.75

Safe handling of chemical toxicants and control of interferences in human tissue analysis for dioxins and furans. Environ Sci Technol (1986) 0.75

Training consistent task components: application of automatic and controlled processing theory to industrial task training. Hum Factors (1987) 0.75

Insulin resistance in total lipodystrophy: evidence for a pre-receptor defect in insulin action. Metabolism (1985) 0.75

Biological variability in the concentration of serum lipids: sources, meta-analysis, estimation, and minimization by relative range measurements. J Int Fed Clin Chem (1995) 0.75

Progress in lipid reporting practices and reliability of blood cholesterol measurement in clinical laboratories in Nebraska. Efforts to align results with the Centers for Disease Control, and feasibility of meeting National Cholesterol Education Program Guidelines. JAMA (1989) 0.75

Use of a glucose-controlled insulin infusion system in children and adolescents with insulin-dependent diabetes. Pediatrics (1982) 0.75

Analyzing quality-control trends with moving slope charts. Clin Chem (1991) 0.75

Cholesterol testing and standardization. J Med Assoc Ga (1991) 0.75