Published in Rep U S on December 20, 2012
Towards Robot-Assisted Vitreoretinal Surgery: Force-Sensing Micro-Forceps Integrated with a Handheld Micromanipulator. IEEE Int Conf Robot Autom (2014) 0.92
A Comparative Study for Robot Assisted Vitreoretinal Surgery: Micron vs. the Steady-Hand Robot. IEEE Int Conf Robot Autom (2013) 0.91
Motorized Force-Sensing Micro-Forceps with Tremor Cancelling and Controlled Micro-Vibrations for Easier Membrane Peeling. Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron (2014) 0.81
Toward Hybrid Position/Force Control for an Active Handheld Micromanipulator. IEEE Int Conf Robot Autom (2014) 0.77
Hybrid position/force control of an active handheld micromanipulator for membrane peeling. Int J Med Robot (2015) 0.75
Intraocular Microsurgical Forceps (20, 23, and 25 gauge) Membrane Peeling Forces Assessment. J Ophthalmol (2013) 0.75
Human eye phantom for developing computer and robot-assisted epiretinal membrane peeling. Conf Proc IEEE Eng Med Biol Soc (2014) 0.75
A "Smart" Force-Limiting Instrument for Microsurgery: Laboratory and In Vivo Validation. PLoS One (2016) 0.75
Effects of Micro-Vibratory Modulation during Robot-Assisted Membrane Peeling. Rep U S (2016) 0.75
Applied force during vitreoretinal microsurgery with handheld instruments. Conf Proc IEEE Eng Med Biol Soc (2004) 3.21
New Steady-Hand Eye Robot with Micro-Force Sensing for Vitreoretinal Surgery. Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron (2010) 3.02
A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. Int J Comput Assist Radiol Surg (2009) 2.98
Micron: an Actively Stabilized Handheld Tool for Microsurgery. IEEE Trans Robot (2011) 2.87
Robot-assisted vitreoretinal surgery: development of a prototype and feasibility studies in an animal model. Ophthalmology (2009) 2.85
Micro-force sensing in robot assisted membrane peeling for vitreoretinal surgery. Med Image Comput Comput Assist Interv (2010) 2.47
Characterization of epiretinal membranes using optical coherence tomography. Ophthalmology (1996) 2.44
Effect of sensory substitution on suture-manipulation forces for robotic surgical systems. J Thorac Cardiovasc Surg (2005) 2.28
Evaluation of a telerobotic system to assist surgeons in microsurgery. Comput Aided Surg (1999) 2.13
Ophthalmic microsurgical robot and associated virtual environment. Comput Biol Med (1995) 1.62
Distribution of iatrogenic retinal breaks in macular hole surgery. Ophthalmology (1995) 1.42
Toward robot-assisted vascular microsurgery in the retina. Graefes Arch Clin Exp Ophthalmol (1997) 1.38
Iatrogenic retinal breaks complicating pars plana vitrectomy. Ophthalmology (1990) 1.23
Mechanical and neural feedback factors in postural hand tremor of normal subjects. J Neurophysiol (1980) 1.22
Retinal microvascular surgery: a feasibility study. Invest Ophthalmol Vis Sci (2004) 1.17
A prototype surgical manipulator for robotic intraocular micro surgery. Stud Health Technol Inform (2009) 1.13
Epiretinal membrane removal in diabetic eyes: comparison of viscodissection with conventional methods of membrane peeling. Br J Ophthalmol (2003) 1.12
Sub-retinal hemorrhage during internal limiting membrane peeling for a macular hole. Graefes Arch Clin Exp Ophthalmol (2003) 1.10
High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities. Int J Radiat Oncol Biol Phys (2008) 3.55
Applied force during vitreoretinal microsurgery with handheld instruments. Conf Proc IEEE Eng Med Biol Soc (2004) 3.21
High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing. IEEE Trans Instrum Meas (2009) 3.04
New Steady-Hand Eye Robot with Micro-Force Sensing for Vitreoretinal Surgery. Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron (2010) 3.02
A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. Int J Comput Assist Radiol Surg (2009) 2.98
Micron: an Actively Stabilized Handheld Tool for Microsurgery. IEEE Trans Robot (2011) 2.87
MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement. IEEE ASME Trans Mechatron (2008) 2.67
Micro-force sensing in robot assisted membrane peeling for vitreoretinal surgery. Med Image Comput Comput Assist Interv (2010) 2.47
Single fiber optical coherence tomography microsurgical instruments for computer and robot-assisted retinal surgery. Med Image Comput Comput Assist Interv (2009) 2.18
Semiautomated intraocular laser surgery using handheld instruments. Lasers Surg Med (2010) 2.13
A Miniature Mobile Robot for Navigation and Positioning on the Beating Heart. IEEE Trans Robot (2009) 2.07
Modeling of needle steering via duty-cycled spinning. Conf Proc IEEE Eng Med Biol Soc (2007) 2.07
Pigment epithelium-derived factor suppresses ischemia-induced retinal neovascularization and VEGF-induced migration and growth. Invest Ophthalmol Vis Sci (2002) 2.03
Tracking Control of Hysteretic Piezoelectric Actuator using Adaptive Rate-Dependent Controller. Sens Actuators A Phys (2009) 1.96
Cell micromanipulation with an active handheld micromanipulator. Conf Proc IEEE Eng Med Biol Soc (2010) 1.96
Endoscopic Functional Fourier Domain Common Path Optical Coherence Tomography for Microsurgery. IEEE J Sel Top Quantum Electron (2010) 1.88
Image-guided small animal radiation research platform: calibration of treatment beam alignment. Phys Med Biol (2009) 1.72
Force sensing micro-forceps for robot assisted retinal surgery. Conf Proc IEEE Eng Med Biol Soc (2012) 1.65
Miniature fiber-optic force sensor based on low-coherence Fabry-Pérot interferometry for vitreoretinal microsurgery. Biomed Opt Express (2012) 1.63
Compact Sensing Design of a Handheld Active Tremor Compensation Instrument. IEEE Sens J (2009) 1.59
Inducible expression of vascular endothelial growth factor in adult mice causes severe proliferative retinopathy and retinal detachment. Am J Pathol (2002) 1.59
AAV-mediated gene transfer of pigment epithelium-derived factor inhibits choroidal neovascularization. Invest Ophthalmol Vis Sci (2002) 1.58
Scale-invariant registration of monocular endoscopic images to CT-scans for sinus surgery. Med Image Anal (2005) 1.50
Estimating Displacement of Periodic Motion With Inertial Sensors. IEEE Sens J (2009) 1.48
Evaluation of a computerized measurement technique for joint alignment before and during periacetabular osteotomy. Comput Aided Surg (2007) 1.44
Increased expression of brain-derived neurotrophic factor preserves retinal function and slows cell death from rhodopsin mutation or oxidative damage. J Neurosci (2003) 1.44
Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches. IEEE Int Conf Robot Autom (2010) 1.41
Small animal radiation research platform: imaging, mechanics, control and calibration. Med Image Comput Comput Assist Interv (2007) 1.40
A submillimetric 3-DOF force sensing instrument with integrated fiber Bragg grating for retinal microsurgery. IEEE Trans Biomed Eng (2014) 1.35
Handheld Micromanipulation with Vision-Based Virtual Fixtures. IEEE Int Conf Robot Autom (2011) 1.32
Robotic assistance for ultrasound-guided prostate brachytherapy. Med Image Anal (2008) 1.32
Statistical atlases of bone anatomy: construction, iterative improvement and validation. Med Image Comput Comput Assist Interv (2007) 1.28
System for robotically assisted prostate biopsy and therapy with intraoperative CT guidance. Acad Radiol (2002) 1.28
Vitreous levels of pigment epithelium-derived factor and vascular endothelial growth factor: implications for ocular angiogenesis. Am J Ophthalmol (2004) 1.26
Towards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery. Opt Express (2010) 1.22
Minimally invasive epicardial injections using a novel semiautonomous robotic device. Circulation (2008) 1.21
Retinal vessel cannulation with an image-guided handheld robot. Conf Proc IEEE Eng Med Biol Soc (2010) 1.21
Hybrid cone-beam tomographic reconstruction: incorporation of prior anatomical models to compensate for missing data. IEEE Trans Med Imaging (2010) 1.21
Intraoperative image-based multiview 2D/3D registration for image-guided orthopaedic surgery: incorporation of fiducial-based C-arm tracking and GPU-acceleration. IEEE Trans Med Imaging (2011) 1.21
DaVinci canvas: a telerobotic surgical system with integrated, robot-assisted, laparoscopic ultrasound capability. Med Image Comput Comput Assist Interv (2005) 1.18
Regression of ocular neovascularization in response to increased expression of pigment epithelium-derived factor. Invest Ophthalmol Vis Sci (2002) 1.16
Active Guidance of a Handheld Micromanipulator using Visual Servoing. IEEE Int Conf Robot Autom (2009) 1.15
Development of an image-guided robot for small animal research. Comput Aided Surg (2007) 1.15
Cooperative robot assistant for retinal microsurgery. Med Image Comput Comput Assist Interv (2008) 1.14
Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration. Urology (2009) 1.14
Different effects of angiopoietin-2 in different vascular beds: new vessels are most sensitive. FASEB J (2005) 1.12
Synchronization of epicardial crawling robot with heartbeat and respiration for improved safety and efficiency of locomotion. Int J Med Robot (2011) 1.12
Deformable 2D-3D registration of the pelvis with a limited field of view, using shape statistics. Med Image Comput Comput Assist Interv (2007) 1.12
Advanced glycation endproduct-induced aging of the retinal pigment epithelium and choroid: a comprehensive transcriptional response. Proc Natl Acad Sci U S A (2005) 1.09
A force-sensing microsurgical instrument that detects forces below human tactile sensation. Retina (2013) 1.08
Optical coherence tomography scanning with a handheld vitreoretinal micromanipulator. Conf Proc IEEE Eng Med Biol Soc (2012) 1.07
MRI compatibility of robot actuation techniques--a comparative study. Med Image Comput Comput Assist Interv (2008) 1.06
A potential role for beta- and gamma-crystallins in the vascular remodeling of the eye. Dev Dyn (2005) 1.04
Retina-specific expression of PDGF-B versus PDGF-A: vascular versus nonvascular proliferative retinopathy. Invest Ophthalmol Vis Sci (2002) 1.04
Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention. IEEE ASME Trans Mechatron (2011) 1.03
Projected tetrahedra revisited: a barycentric formulation applied to digital radiograph reconstruction using higher-order attenuation functions. IEEE Trans Vis Comput Graph (2006) 1.03
Percutaneous intracerebral navigation by duty-cycled spinning of flexible bevel-tipped needles. Neurosurgery (2010) 1.03
Test of tracing performance with an active handheld micromanipulator. Conf Proc IEEE Eng Med Biol Soc (2007) 1.03
A parallel wire robot for epicardial interventions. Conf Proc IEEE Eng Med Biol Soc (2014) 1.03
A system for video-based navigation for endoscopic endonasal skull base surgery. IEEE Trans Med Imaging (2011) 1.02
In-bore setup and software for 3T MRI-guided transperineal prostate biopsy. Phys Med Biol (2012) 1.02
Robot-assisted stapedotomy: micropick fenestration of the stapes footplate. Otolaryngol Head Neck Surg (2002) 1.01
MRI image overlay: application to arthrography needle insertion. Comput Aided Surg (2007) 1.01
Notch signaling promotes growth and invasion in uveal melanoma. Clin Cancer Res (2012) 1.01
Auditory force feedback substitution improves surgical precision during simulated ophthalmic surgery. Invest Ophthalmol Vis Sci (2013) 1.01
Accuracy study of a robotic system for MRI-guided prostate needle placement. Int J Med Robot (2012) 0.97
Lung deformation estimation and four-dimensional CT lung reconstruction. Acad Radiol (2006) 0.97
Robotic system for MRI-guided prostate biopsy: feasibility of teleoperated needle insertion and ex vivo phantom study. Int J Comput Assist Radiol Surg (2011) 0.97
Comparative evaluation of monocular augmented-reality display for surgical microscopes. Conf Proc IEEE Eng Med Biol Soc (2012) 0.96
Interventions for central serous chorioretinopathy: a network meta-analysis. Cochrane Database Syst Rev (2015) 0.96
Design of 3-DOF force sensing micro-forceps for robot assisted vitreoretinal surgery. Conf Proc IEEE Eng Med Biol Soc (2013) 0.94
Image overlay guidance for needle insertion in CT scanner. IEEE Trans Biomed Eng (2005) 0.94
Needle steering system using duty-cycled rotation for percutaneous kidney access. Conf Proc IEEE Eng Med Biol Soc (2010) 0.93
Precision radiotherapy for small animal research. Med Image Comput Comput Assist Interv (2008) 0.92
Preliminary Evaluation of a MRI-compatible Modular Robotic System for MRI-guided Prostate Interventions. Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron (2010) 0.92
Retinal metastasis presenting as a retinal hemorrhage in a patient with adenocarcinoma of the cecum. Arch Ophthalmol (2005) 0.92
Effects of tools inserted through snake-like surgical manipulators. Conf Proc IEEE Eng Med Biol Soc (2014) 0.91
A workspace-orientated needle-guiding robot for 3T MRI-guided transperineal prostate intervention: evaluation of in-bore workspace and MRI compatibility. Int J Med Robot (2012) 0.91