Multi-slice-to-volume registration for MRI-guided transperineal prostate biopsy.

PubWeight™: 0.75‹?›

🔗 View Article (PMID 25193145)

Published in Int J Comput Assist Radiol Surg on September 06, 2014

Authors

Helen Xu1, Andras Lasso, Andriy Fedorov, Kemal Tuncali, Clare Tempany, Gabor Fichtinger

Author Affiliations

1: School of Computing, Queen's University, Kingston, Canada, helen@cs.queensu.ca.

Articles cited by this

Engineering and algorithm design for an image processing Api: a technical report on ITK--the Insight Toolkit. Stud Health Technol Inform (2002) 4.65

MR-guided biopsy of the prostate: an overview of techniques and a systematic review. Eur Urol (2008) 2.77

The sextant protocol for ultrasound-guided core biopsies of the prostate underestimates the presence of cancer. Urology (1997) 2.29

The contemporary concept of significant versus insignificant prostate cancer. Eur Urol (2011) 2.29

Slice-to-volume registration and its potential application to interventional MRI-guided radio-frequency thermal ablation of prostate cancer. IEEE Trans Med Imaging (2003) 1.96

Predicting cancer following a diagnosis of high-grade prostatic intraepithelial neoplasia on needle biopsy: data on men with more than one follow-up biopsy. Am J Surg Pathol (2001) 1.87

MR imaging-guided prostate biopsy with surgical navigation software: device validation and feasibility. Radiology (2001) 1.74

Comparison of mid-lobe versus lateral systematic sextant biopsies in the detection of prostate cancer. Urol Int (1997) 1.60

MR-guided prostate interventions. J Magn Reson Imaging (2008) 1.18

In-bore setup and software for 3T MRI-guided transperineal prostate biopsy. Phys Med Biol (2012) 1.02

Analytic regularization for landmark-based image registration. Phys Med Biol (2012) 0.95

Strategies for repeat prostate biopsies. Curr Urol Rep (2009) 0.89

Accuracy analysis in MRI-guided robotic prostate biopsy. Int J Comput Assist Radiol Surg (2013) 0.87

Target motion tracking in MRI-guided transrectal robotic prostate biopsy. IEEE Trans Biomed Eng (2011) 0.86

Articles by these authors

A shape-based approach to the segmentation of medical imagery using level sets. IEEE Trans Med Imaging (2003) 6.80

Design of a novel MRI compatible manipulator for image guided prostate interventions. IEEE Trans Biomed Eng (2005) 3.08

OpenIGTLink: an open network protocol for image-guided therapy environment. Int J Med Robot (2009) 2.80

Correlation and simple linear regression. Radiology (2003) 2.68

MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement. IEEE ASME Trans Mechatron (2008) 2.67

MRI guidance of focused ultrasound therapy of uterine fibroids: early results. AJR Am J Roentgenol (2004) 2.19

Transrectal prostate biopsy and fiducial marker placement in a standard 1.5T magnetic resonance imaging scanner. J Urol (2006) 1.96

Clonal evolution of resistance to imatinib in patients with metastatic gastrointestinal stromal tumors. Clin Cancer Res (2007) 1.94

FTRAC--a robust fluoroscope tracking fiducial. Med Phys (2005) 1.91

System for MR image-guided prostate interventions: canine study. Radiology (2003) 1.89

Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study. J Magn Reson Imaging (2007) 1.70

Neoadjuvant docetaxel before radical prostatectomy in patients with high-risk localized prostate cancer. Clin Cancer Res (2005) 1.68

Challenges in image-guided therapy system design. Neuroimage (2007) 1.61

Multiparametric MRI of prostate cancer: an update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. J Magn Reson Imaging (2013) 1.54

MR imaging-controlled focused ultrasound ablation: a noninvasive image-guided surgery. Magn Reson Imaging Clin N Am (2005) 1.52

Image registration for targeted MRI-guided transperineal prostate biopsy. J Magn Reson Imaging (2012) 1.50

Renal masses in the adult patient: the role of percutaneous biopsy. Radiology (2006) 1.50

Matching and reconstruction of brachytherapy seeds using the Hungarian algorithm (MARSHAL). Med Phys (2005) 1.49

Liver metastases: 3D shape-based analysis of CT scans for detection of local recurrence after radiofrequency ablation. Radiology (2006) 1.45

Renal tumors: MR imaging-guided percutaneous cryotherapy--initial experience in 23 patients. Radiology (2005) 1.45

Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches. IEEE Int Conf Robot Autom (2010) 1.41

Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery. Neuroimage (2006) 1.41

Hyperattenuating renal masses: etiologies, pathogenesis, and imaging evaluation. Radiographics (2007) 1.34

Optimized prostate biopsy via a statistical atlas of cancer spatial distribution. Med Image Anal (2004) 1.33

GBM volumetry using the 3D Slicer medical image computing platform. Sci Rep (2013) 1.30

Magnetic resonance-guided interstitial therapy for vaginal recurrence of endometrial cancer. Int J Radiat Oncol Biol Phys (2006) 1.28

Comparison of percutaneous and surgical approaches to renal tumor ablation: metaanalysis of effectiveness and complication rates. J Vasc Interv Radiol (2008) 1.26

Targeted prostate biopsy using statistical image analysis. IEEE Trans Med Imaging (2007) 1.25

PLUS: open-source toolkit for ultrasound-guided intervention systems. IEEE Trans Biomed Eng (2014) 1.21

Patient selection determines the prostate cancer yield of dynamic contrast-enhanced magnetic resonance imaging-guided transrectal biopsies in a closed 3-Tesla scanner. BJU Int (2007) 1.19

Ultrasound elastography: a dynamic programming approach. IEEE Trans Med Imaging (2008) 1.15

Development of an image-guided robot for small animal research. Comput Aided Surg (2007) 1.15

An MRI-compatible robotic system with hybrid tracking for MRI-guided prostate intervention. IEEE Trans Biomed Eng (2011) 1.14

Imaging-guided percutaneous ablation of renal cell carcinoma: a primer of how we do it. AJR Am J Roentgenol (2009) 1.13

Transperineal in-bore 3-T MR imaging-guided prostate biopsy: a prospective clinical observational study. Radiology (2014) 1.13

Integrated navigation and control software system for MRI-guided robotic prostate interventions. Comput Med Imaging Graph (2009) 1.13

Accuracy validation for MRI-guided robotic prostate biopsy. Proc SPIE Int Soc Opt Eng (2010) 1.08

C-arm tracking and reconstruction without an external tracker. Med Image Comput Comput Assist Interv (2006) 1.07

Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention. IEEE ASME Trans Mechatron (2011) 1.03

MRI-guided cryotherapy. J Magn Reson Imaging (2008) 1.03

Percutaneous cryoablation techniques and clinical applications. Diagn Interv Radiol (2009) 1.03

Monitoring tumor motion by real time 2D/3D registration during radiotherapy. Radiother Oncol (2011) 1.03

Robotic assistant for transperineal prostate interventions in 3T closed MRI. Med Image Comput Comput Assist Interv (2007) 1.02

Image-guided thermal therapy of uterine fibroids. Semin Ultrasound CT MR (2009) 1.02

In-bore setup and software for 3T MRI-guided transperineal prostate biopsy. Phys Med Biol (2012) 1.02

Multi-detector row CT urography of normal urinary collecting system: furosemide versus saline as adjunct to contrast medium. Radiology (2006) 1.02

Simultaneous integrated boost of biopsy proven, MRI defined dominant intra-prostatic lesions to 95 Gray with IMRT: early results of a phase I NCI study. Radiat Oncol (2007) 1.01

MRI image overlay: application to arthrography needle insertion. Comput Aided Surg (2007) 1.01

PROBABILISTIC NON-RIGID REGISTRATION OF PROSTATE IMAGES: MODELING AND QUANTIFYING UNCERTAINTY. Proc IEEE Int Symp Biomed Imaging (2011) 1.00

Evaluation of referenceless thermometry in MRI-guided focused ultrasound surgery of uterine fibroids. J Magn Reson Imaging (2008) 1.00

Inflammatory nodules mimic applicator track seeding after percutaneous ablation of renal tumors. AJR Am J Roentgenol (2007) 1.00

Spinal needle navigation by tracked ultrasound snapshots. IEEE Trans Biomed Eng (2012) 1.00

PET/CT-guided percutaneous biopsy of abdominal masses: initial experience. J Vasc Interv Radiol (2011) 1.00

MRI-guided robotic prostate biopsy: a clinical accuracy validation. Med Image Comput Comput Assist Interv (2010) 0.99

Informatics methods to enable sharing of quantitative imaging research data. Magn Reson Imaging (2012) 0.99

Practical considerations in T1 mapping of prostate for dynamic contrast enhancement pharmacokinetic analyses. Magn Reson Imaging (2012) 0.99

Abdominal masses sampled at PET/CT-guided percutaneous biopsy: initial experience with registration of prior PET/CT images. Radiology (2010) 0.98

A coupled global registration and segmentation framework with application to magnetic resonance prostate imagery. IEEE Trans Med Imaging (2010) 0.98

Accuracy study of a robotic system for MRI-guided prostate needle placement. Int J Med Robot (2012) 0.97

Late genitourinary and gastrointestinal toxicity after magnetic resonance image-guided prostate brachytherapy with or without neoadjuvant external beam radiation therapy. Cancer (2003) 0.97

Robotic system for MRI-guided prostate biopsy: feasibility of teleoperated needle insertion and ex vivo phantom study. Int J Comput Assist Radiol Surg (2011) 0.97

Lung deformation estimation and four-dimensional CT lung reconstruction. Acad Radiol (2006) 0.97

Radiofrequency ablation of thoracic lesions: part 2, initial clinical experience--technical and multidisciplinary considerations in 30 patients. AJR Am J Roentgenol (2005) 0.97

REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction. IEEE Trans Med Imaging (2010) 0.95

Multimodality non-rigid image registration for planning, targeting and monitoring during CT-guided percutaneous liver tumor cryoablation. Acad Radiol (2010) 0.95

Radiofrequency ablation of liver tumors: a new cause of benign portal venous gas. Radiology (2005) 0.95

Successful percutaneous radiologic management of renal cell carcinoma tumor seeding caused by percutaneous biopsy performed before ablation. J Vasc Interv Radiol (2013) 0.95

Two solutions for registration of ultrasound to MRI for image-guided prostate interventions. Conf Proc IEEE Eng Med Biol Soc (2012) 0.94

Prostate implant reconstruction with discrete tomography. Med Image Comput Comput Assist Interv (2007) 0.94

Biopsy needle artifact localization in MRI-guided robotic transrectal prostate intervention. IEEE Trans Biomed Eng (2012) 0.93

Surgical task and skill classification from eye tracking and tool motion in minimally invasive surgery. Med Image Comput Comput Assist Interv (2010) 0.93

Software strategy for robotic transperineal prostate therapy in closed-bore MRI. Med Image Comput Comput Assist Interv (2008) 0.92

Toward optimal matching for 3D reconstruction of brachytherapy seeds. Med Image Comput Comput Assist Interv (2007) 0.92

Design and preliminary accuracy studies of an MRI-guided transrectal prostate intervention system. Med Image Comput Comput Assist Interv (2007) 0.92

Preliminary Evaluation of a MRI-compatible Modular Robotic System for MRI-guided Prostate Interventions. Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron (2010) 0.92

Ultrasound monitoring of tissue ablation via deformation model and shape priors. Med Image Comput Comput Assist Interv (2006) 0.92

Workflow modeling and analysis of computer guided prostate brachytherapy under MR imaging control. Stud Health Technol Inform (2004) 0.91

A workspace-orientated needle-guiding robot for 3T MRI-guided transperineal prostate intervention: evaluation of in-bore workspace and MRI compatibility. Int J Med Robot (2012) 0.91

Intraoperative segmentation of iodine and palladium radioactive sources in C-arm images. Int J Comput Assist Radiol Surg (2014) 0.90

Variability in MRI vs. ultrasound measures of prostate volume and its impact on treatment recommendations for favorable-risk prostate cancer patients: a case series. Radiat Oncol (2014) 0.90

Perk Tutor: an open-source training platform for ultrasound-guided needle insertions. IEEE Trans Biomed Eng (2012) 0.89

SlicerRT: radiation therapy research toolkit for 3D Slicer. Med Phys (2012) 0.89

Ablation monitoring with elastography: 2D in-vivo and 3D ex-vivo studies. Med Image Comput Comput Assist Interv (2008) 0.89

Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost. IEEE Trans Med Imaging (2009) 0.89

Surgical and Interventional Robotics: Core Concepts, Technology, and Design. IEEE Robot Autom Mag (2008) 0.89

The effect of augmented reality training on percutaneous needle placement in spinal facet joint injections. IEEE Trans Biomed Eng (2011) 0.89